20 research outputs found

    Timing Resistive Plate Chambers with Ceramic Electrodes: for Particle and Nuclear Physics Experiments

    Get PDF
    The focus of this thesis is the development of Resistive Plate Chambers (RPCs) with ceramic electrodes. The use of ceramic composites, Si3N4/SiC, opens the way for the application of RPCs in harsh radiation environments. Future Experiments like the Compressed Baryonic Matter (CBM) at the Facility for Antiproton and Ion Research (FAIR) in Darmstadt will need new RPCs with high rate capabilities and high radiation tolerance. Ceramic composites are specially suited for this purpose due to their resistance to radiation and chemical contamination. The bulk resistivity of these ceramics is in the range 10^7 - 10^13 Ohm cm. The bulk resistivity of the electrodes is the main factor determining the rate capabilities of a RPC, therefore a specifific measuring station and a measurement protocol has been set for these measurements. The dependence of the bulk resistivity on the difffferent steps of the manufacturing process has been studied. Other electrical parameters like the relaxation time, the relative permittivity and the tangent loss have also been investigated. Simulation codes for the investigation of RPC functionality was developed using the gas detectors simulation framework GARFIELD++. The parameters of the two mixtures used in RPC operation have been extracted. Furthermore, theoretical predictions on time resolution and effi ciency have been calculated and compared with experimental results. Two ceramic materials have been used to assemble RPCs. Si3N4/SiC and Al2O3 with a thin (nm thick) chromium layer deposited over it. Several prototypes have been assembled with active areas of 5x 5 cm^2, 10x 10 cm^2 and 20 x20 cm^2. The number of gaps ranges from two to six. The gas gap widths were 250 micro meter and 300 micrometer. As separator material mylar foils, fifishing line and high-resistive ceramics have been used. Different detector architectures have been built and their effffect on RPC performance analysed. The RPCs developed at HZDR and ITEP (Moscow) were systematically tested in electron and proton beams and with cosmic radiation over the course of three years. The performance of the RPCs was extracted from the measured data. The main parameters like time resolution, effi ciency, rate capabilities, cluster size, detector currents and avalanche charge were obtained and compared with other RPC systems in the world. A comparison with phenomenological models was performed

    Observation of ultrafast solid-density plasma dynamics using femtosecond X-ray pulses from a free-electron laser

    Get PDF
    The complex physics of the interaction between short pulse high intensity lasers and solids is so far hardly accessible by experiments. As a result of missing experimental capabilities to probe the complex electron dynamics and competing instabilities, this impedes the development of compact laser-based next generation secondary radiation sources, e.g. for tumor therapy [Bulanov2002,ledingham2007], laboratory-astrophysics [Remington1999,Bulanov2015], and fusion [Tabak2014]. At present, the fundamental plasma dynamics that occur at the nanometer and femtosecond scales during the laser-solid interaction can only be elucidated by simulations. Here we show experimentally that small angle X-ray scattering of femtosecond X-ray free-electron laser pulses facilitates new capabilities for direct in-situ characterization of intense short-pulse laser plasma interaction at solid density that allows simultaneous nanometer spatial and femtosecond temporal resolution, directly verifying numerical simulations of the electron density dynamics during the short pulse high intensity laser irradiation of a solid density target. For laser-driven grating targets, we measure the solid density plasma expansion and observe the generation of a transient grating structure in front of the pre-inscribed grating, due to plasma expansion, which is an hitherto unknown effect. We expect that our results will pave the way for novel time-resolved studies, guiding the development of future laser-driven particle and photon sources from solid targets

    Visualizing Ultrafast Kinetic Instabilities in Laser-Driven Solids using X-ray Scattering

    Full text link
    Ultra-intense lasers that ionize and accelerate electrons in solids to near the speed of light can lead to kinetic instabilities that alter the laser absorption and subsequent electron transport, isochoric heating, and ion acceleration. These instabilities can be difficult to characterize, but a novel approach using X-ray scattering at keV energies allows for their visualization with femtosecond temporal resolution on the few nanometer mesoscale. Our experiments on laser-driven flat silicon membranes show the development of structure with a dominant scale of ~60\unit{nm} in the plane of the laser axis and laser polarization, and ~95\unit{nm} in the vertical direction with a growth rate faster than 0.1/fs0.1/\mathrm{fs}. Combining the XFEL experiments with simulations provides a complete picture of the structural evolution of ultra-fast laser-induced instability development, indicating the excitation of surface plasmons and the growth of a new type of filamentation instability. These findings provide new insight into the ultra-fast instability processes in solids under extreme conditions at the nanometer level with important implications for inertial confinement fusion and laboratory astrophysics

    Laser produced electromagnetic pulses : Generation, detection and mitigation

    Get PDF
    This paper provides an up-to-date review of the problems related to the generation, detection and mitigation of strong electromagnetic pulses created in the interaction of high-power, high-energy laser pulses with different types of solid targets. It includes new experimental data obtained independently at several international laboratories. The mechanisms of electromagnetic field generation are analyzed and considered as a function of the intensity and the spectral range of emissions they produce. The major emphasis is put on the gHz frequency domain, which is the most damaging for electronics and may have important applications. The physics of electromagnetic emissions in other spectral domains, in particular THz and MHz, is also discussed. The theoretical models and numerical simulations are compared with the results of experimental measurements, with special attention to the methodology of measurements and complementary diagnostics. Understanding the underlying physical processes is the basis for developing techniques to mitigate the electromagnetic threat and to harness electromagnetic emissions, which may have promising applications

    CIBERER : Spanish national network for research on rare diseases: A highly productive collaborative initiative

    Get PDF
    Altres ajuts: Instituto de Salud Carlos III (ISCIII); Ministerio de Ciencia e Innovación.CIBER (Center for Biomedical Network Research; Centro de Investigación Biomédica En Red) is a public national consortium created in 2006 under the umbrella of the Spanish National Institute of Health Carlos III (ISCIII). This innovative research structure comprises 11 different specific areas dedicated to the main public health priorities in the National Health System. CIBERER, the thematic area of CIBER focused on rare diseases (RDs) currently consists of 75 research groups belonging to universities, research centers, and hospitals of the entire country. CIBERER's mission is to be a center prioritizing and favoring collaboration and cooperation between biomedical and clinical research groups, with special emphasis on the aspects of genetic, molecular, biochemical, and cellular research of RDs. This research is the basis for providing new tools for the diagnosis and therapy of low-prevalence diseases, in line with the International Rare Diseases Research Consortium (IRDiRC) objectives, thus favoring translational research between the scientific environment of the laboratory and the clinical setting of health centers. In this article, we intend to review CIBERER's 15-year journey and summarize the main results obtained in terms of internationalization, scientific production, contributions toward the discovery of new therapies and novel genes associated to diseases, cooperation with patients' associations and many other topics related to RD research

    Efficient laser-driven proton and bremsstrahlung generation from cluster-assembled foam targets

    Get PDF
    International audienceThe interaction between intense 30 fs laser pulses and foam-coated 1.5 μm-thick Al foils in the relativistic regime (up to 5 × 1020^{20} W cm2^{−2} ) is studied to optimize the laser energy conversion into laser-accelerated protons. A significant enhancement is observed for foam targets in terms of proton cut-off energy (18.5 MeV) and number of protons above 4.7 MeV (4 × 109^9 protons/shot) with respect to uncoated foils (9.5 MeV, 1 × 109^9 protons/shot), together with a sixfold increase in the bremsstrahlung yield. This enhancement is attributed to increased laser absorption and electron generation in the foam meso- and nanostructure

    Ultra high-speed x-ray imaging of laser-driven shock compression using synchrotron light

    No full text
    International audienceA high-power, nanosecond pulsed laser impacting the surface of a material can generate an ablation plasma that drives a shock wave into it; while in situ x-ray imaging can provide a time-resolved probe of the shock-induced material behaviour on macroscopic length scales. Here, we report on an investigation into laser-driven shock compression of a polyurethane foam and a graphite rod by means of single-pulse synchrotron x-ray phase-contrast imaging with MHz frame rate. A 6 J, 10 ns pulsed laser was used to generate shock compression. Physical processes governing the laser-induced dynamic response such as elastic compression, compaction, pore collapse, fracture, and fragmentation have been imaged; and the advantage of exploiting the partial spatial coherence of a synchrotron source for studying low-density, carbon-based materials is emphasized. The successful combination of a high-energy laser and ultra high-speed x-ray imaging using synchrotron light demonstrates the potentiality of accessing complementary information from scientific studies of laser-driven shock compression

    Urinary sulphatoxymelatonin as a biomarker of serotonin status in biogenic amine-deficient patients

    No full text
    Abstract Melatonin is synthesized from serotonin and it is excreted as sulphatoxymelatonin in urine. We aim to evaluate urinary sulphatoxymelatonin as a biomarker of brain serotonin status in a cohort of patients with mutations in genes related to serotonin biosynthesis. We analized urinary sulphatoxymelatonin from 65 healthy subjects and from 28 patients with genetic defects. A total of 18 patients were studied: 14 with autosomal dominant and recessive guanosine triphosphate cyclohydrolase-I deficiency; 3 with sepiapterin reductase deficiency; and 1 with aromatic L-amino acid decarboxylase deficiency. Further 11 patients were studied after receiving serotoninergic treatment (serotonin precursors, monoamine oxidase inhibitors, selective serotonin re-uptake inhibitors): 5 with aromatic L-amino acid decarboxylase deficiency; 1 with sepiapterin reductase deficiency; 3 with dihydropteridine reductase deficiency; and 2 with 6-pyruvoyltetrahydropterin synthase deficiency. Among the patients without therapy, 6 presented low urinary sulphatoxymelatonin values, while most of the patients with guanosine triphosphate cyclohydrolase-I deficiency showed normal values. 5 of 11 patients under treatment presented low urine sulphatoxymelatonin values. Thus, decreased excretion of sulphatoxymelatonin is frequently observed in cases with severe genetic disorders affecting serotonin biosynthesis. In conclusion, sulphatoxymelatonin can be a good biomarker to estimate serotonin status in the brain, especially for treatment monitoring purposes

    Towards perfectly linearly polarized x-rays

    No full text
    In recent years, high-precision x-ray polarimeters have become a key method for the investigation of fundamental physical questions from solid-state physics to quantum optics. Here, we report on the verification of a polarization purity of better than 8×10118×10^{−11} at an x-ray free-electron laser, which implies a suppression of the incoming photons to the noise level in the crossed polarizer setting. This purity provides exceptional sensitivity to tiny polarization changes and offers intriguing perspectives for fundamental tests of quantum electrodynamics
    corecore