68 research outputs found

    Rib Cortical Bone Fracture Risk as a Function of Age and Rib Strain: Updated Injury Prediction Using Finite Element Human Body Models

    Get PDF
    To evaluate vehicle occupant injury risk, finite element human body models (HBMs) can be used in vehicle crash simulations. HBMs can predict tissue loading levels, and the risk for fracture can be estimated based on a tissue-based risk curve. A probabilistic framework utilizing an age-adjusted rib strain-based risk function was proposed in 2012. However, the risk function was based on tests from only twelve human subjects. Further, the age adjustment was based on previous literature postulating a 5.1% decrease in failure strain for femur bone material per decade of aging. The primary aim of this study was to develop a new strain-based rib fracture risk function using material test data spanning a wide range of ages. A second aim was to update the probabilistic framework with the new risk function and compare the probabilistic risk predictions from HBM simulations to both previous HBM probabilistic risk predictions and to approximate real-world rib fracture outcomes. Tensile test data of human rib cortical bone from 58 individuals spanning 17–99 years of ages was used. Survival analysis with accelerated failure time was used to model the failure strain and age-dependent decrease for the tissue-based risk function. Stochastic HBM simulations with varied impact conditions and restraint system settings were performed and probabilistic rib fracture risks were calculated. In the resulting fracture risk function, sex was not a significant covariate—but a stronger age-dependent decrease than previously assumed for human rib cortical bone was evident, corresponding to a 12% decrease in failure strain per decade of aging. The main effect of this difference is a lowered risk prediction for younger individuals than that predicted in previous risk functions. For the stochastic analysis, the previous risk curve overestimated the approximate real-world rib fracture risk for 30-year-old occupants; the new risk function reduces the overestimation. Moreover, the new function can be used as a direct replacement of the previous one within the 2012 probabilistic framework

    A Study of Holographic Renormalization Group Flows in d=6 and d=3

    Get PDF
    We present an explicit study of the holographic renormalization group (RG) in six dimensions using minimal gauged supergravity. By perturbing the theory with the addition of a relevant operator of dimension four one flows to a non-supersymmetric conformal fixed point. There are also solutions describing non-conformal vacua of the same theory obtained by giving an expectation value to the operator. One such vacuum is supersymmetric and is obtained by using the true superpotential of the theory. We discuss the physical acceptability of these vacua by applying the criteria recently given by Gubser for the four dimensional case and find that those criteria give a clear physical picture in the six dimensional case as well. We use this example to comment on the role of the Hamilton-Jacobi equations in implementing the RG. We conclude with some remarks on AdS_4 and the status of three dimensional superconformal theories from squashed solutions of M-theory.Comment: 15 pages, 5 figures, V2: minor change

    Holographic Noncommutativity

    Get PDF
    We examine noncommutative Yang-Mills and open string theories using magnetically and electrically deformed supergravity duals. The duals are near horizon regions of Dp-brane bound state solutions which are obtained by using O(p+1,p+1) transformations of Dp-branes. The action of the T-duality group implies that the noncommutativity parameter is constant along holographic RG-flows. The moduli of the noncommutative theory, i.e., the open string metric and coupling constant, as well as the zero-force condition are shown to be invariant under the O(p+1,p+1) transformation, i.e., deformation independent. We find sufficient conditions, including zero force and constant dilaton in the ISO(3,1)-invariant D3 brane solution, for exact S-duality between noncommutative Yang-Mills and open string theories. These results are used to construct noncommutative field and string theories with N=1 supersymmetry from the T^(1,1) and Pilch-Warner solutions. The latter has a non-trivial zero-force condition due to the warping.Comment: latex, 40 pp. v2: minor changes, one ref. added. v3: corrections in eqs. 27 and 7

    Herschel observations of interstellar chloronium

    Get PDF
    Using the Herschel Space Observatory's Heterodyne Instrument for the Far-Infrared (HIFI), we have observed para-chloronium (H2Cl+) toward six sources in the Galaxy. We detected interstellar chloronium absorption in foreground molecular clouds along the sight-lines to the bright submillimeter continuum sources Sgr A (+50 km/s cloud) and W31C. Both the para-H2-35Cl+ and para-H2-37Cl+ isotopologues were detected, through observations of their 1(11)-0(00) transitions at rest frequencies of 485.42 and 484.23 GHz, respectively. For an assumed ortho-to-para ratio of 3, the observed optical depths imply that chloronium accounts for ~ 4 - 12% of chlorine nuclei in the gas phase. We detected interstellar chloronium emission from two sources in the Orion Molecular Cloud 1: the Orion Bar photodissociation region and the Orion South condensation. For an assumed ortho-to-para ratio of 3 for chloronium, the observed emission line fluxes imply total beam-averaged column densities of ~ 2.0E+13 cm-2 and ~ 1.2E+13 cm-2, respectively, for chloronium in these two sources. We obtained upper limits on the para-H2-35Cl+ line strengths toward H2 Peak 1 in the Orion Molecular cloud and toward the massive young star AFGL 2591. The chloronium abundances inferred in this study are typically at least a factor ~10 larger than the predictions of steady-state theoretical models for the chemistry of interstellar molecules containing chlorine. Several explanations for this discrepancy were investigated, but none has proven satisfactory, and thus the large observed abundances of chloronium remain puzzling.Comment: Accepted for publication in the Astrophysical Journa

    Measuring care of the elderly: psychometric testing and modification of the Time in Care instrument for measurement of care needs in nursing homes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Aging entails not only a decrease in the ability to be active, but also a trend toward increased dependence to sustain basic life functions. An important aspect for appropriately elucidating the individual's care needs is the ability to measure them both simply and reliably. Since 2006 a new version of the Time in Care needs (TIC-n) instrument (19-item version) has been explored and used in one additional municipality with the same structure as the one described in an earlier study.</p> <p>Methods</p> <p>The TIC-n assessment was conducted on a total of 1282 care recipients. Factor analysis (principal component) was applied to explore the construct validity of the TIC-n. Cronbach's alpha was calculated to test reliability and for each of the items remaining in the instrument after factor analysis, an inter-rater comparison was carried out on all recipients in both municipalities. Independently of each other, a weighted Kappa (K<sub>w</sub>) was calculated. Results. The mean of each weighted Kappa (K<sub>w</sub>) for the dimensions in the two municipalities was 0.75 and 0.76, respectively. Factor analysis showed that all 19 items had a factor loading of ≄ 0.40. Three factors (General Care, Medical Care and Cognitive Care) were created.</p> <p>Conclusion</p> <p>The TIC-n instrument has now been tested for validity and reliability in two municipalities with satisfactory results. However, TIC-n can not yet be used as a golden standard, but it can be recommended for use of measurement of individual care needs in municipal elderly care.</p

    Patients' independence of a nurse for the administration of subcutaneous anti-TNF therapy: A phenomenographic study

    Get PDF
    Rheumatology nursing supports patients to manage their lives and live as independently as possible without pain, stiffness and functional restrictions. When conventional drugs fail to delay the development of the rheumatic disease, the patient may require biological treatment such as self-administered subcutaneous anti-tumour necrosis factor (TNF) therapy. It is therefore important that the patient perspective focuses on the life-changing situation caused by the administration of regular subcutaneous injections. The aim of this study was to describe variations in how patients with rheumatic diseases experience their independence of a nurse for administration of subcutaneous anti-TNF therapy. The study had a descriptive, qualitative design with a phenomenographic approach and was carried out by means of 20 interviews. Four ways of understanding the patients' experience of their subcutaneous anti-TNF therapy and independence of a nurse emerged: the struggling patient; the learning patient; the participating patient; the independent patient. Achieving independence of a nurse for subcutaneous anti-TNF injections can be understood by the patients in different ways. In their strive for independence, patients progress by learning about and participating in drug treatment, after which they experience that the injections make them independent

    Odin observations of H2O in the Galactic Centre

    Full text link
    The Odin satellite has been used to detect emission and absorption in the 557-GHz H2O line in the Galactic Centre towards the Sgr A* Circumnuclear Disk (CND), and the Sgr A +20 km/s and +50 km/s molecular clouds. Strong broad H2O emission lines have been detected in all three objects. Narrow H2O absorption lines are present at all three positions and originate along the lines of sight in the 3-kpc Spiral Arm, the -30 km/s Spiral Arm and the Local Sgr Spiral Arm. Broad H2O absorption lines near -130 km/s are also observed, originating in the Expanding Molecular Ring. A new molecular feature (the ``High Positive Velocity Gas'' - HPVG) has been identified in the positive velocity range of ~ +120 to +220 km/s, seen definitely in absorption against the stronger dust continuum emission from the +20 km/s and +50 km/s clouds and possibly in emission towards the position of Sgr A* CND. The 548-GHz H2_18O isotope line towards the CND is not detected at the 0.02 K (rms) level.Comment: 5 pages, 3 figures, accepted by A&A, special Odin Letters issu

    Elevated [11C]-D-Deprenyl Uptake in Chronic Whiplash Associated Disorder Suggests Persistent Musculoskeletal Inflammation

    Get PDF
    There are few diagnostic tools for chronic musculoskeletal pain as structural imaging methods seldom reveal pathological alterations. This is especially true for Whiplash Associated Disorder, for which physical signs of persistent injuries to the neck have yet to be established. Here, we sought to visualize inflammatory processes in the neck region by means Positron Emission Tomography using the tracer 11C-D-deprenyl, a potential marker for inflammation. Twenty-two patients with enduring pain after a rear impact car accident (Whiplash Associated Disorder grade II) and 14 healthy controls were investigated. Patients displayed significantly elevated tracer uptake in the neck, particularly in regions around the spineous process of the second cervical vertebra. This suggests that whiplash patients have signs of local persistent peripheral tissue inflammation, which may potentially serve as a diagnostic biomarker. The present investigation demonstrates that painful processes in the periphery can be objectively visualized and quantified with PET and that 11C-D-deprenyl is a promising tracer for these purposes
    • 

    corecore