573 research outputs found
Optical nonlinear dynamics with cold atoms in a cavity
This paper presents the nonlinear dynamics of laser cooled and trapped cesium
atoms placed inside an optical cavity and interacting with a probe light beam
slightly detuned from the 6S1/2(F=4) to 6P3/2(F=5) transition. The system
exhibits very strong bistability and instabilities. The origin of the latter is
found to be a competition between optical pumping and non-linearities due to
saturation of the optical transition.Comment: 6 pages, 7 figures, LaTe
Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium
The mirror relative motion of a suspended Fabry-Perot cavity is studied in
the frequency range 3-10 Hz. The experimental measurements presented in this
paper, have been performed at the Low Frequency Facility, a high finesse
optical cavity 1 cm long suspended to a mechanical seismic isolation system
identical to that one used in the VIRGO experiment. The measured relative
displacement power spectrum is compatible with a system at thermal equilibrium
within its environmental. In the frequency region above 3 Hz, where seismic
noise contamination is negligible, the measurement distribution is stationary
and Gaussian, as expected for a system at thermal equilibrium. Through a simple
mechanical model it is shown that: applying the fluctuation dissipation theorem
the measured power spectrum is reproduced below 90 Hz and noise induced by
external sources are below the measurement.Comment: 11 pages, 9 figures, 2 tables, to be submitte
Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection
In order to achieve full detection sensitivity at low frequencies, the
mirrors of interferometric gravitational wave detectors must be isolated from
seismic noise. The VIRGO vibration isolator, called 'superattenuator', is fully
effective at frequencies above 4 Hz. Nevertheless, the residual motion of the
mirror at the mechanical resonant frequencies of the system are too large for
the interferometer locking system and must be damped. A multidimensional
feedback system, using inertial sensors and digital processing, has been
designed for this purpose. An experimental procedure for determining the
feedback control of the system has been defined. In this paper a full
description of the system is given and experimental results are presented.Comment: 17 pages, 11 figures, accepted for publication on Review of
Scientific Instrument
Measurement and application of electron stripping of ultrarelativistic
New measurements of the stripping cross-section for ultrarelativistic
hydrogen-like lead ions passing through aluminium and silicon have been
performed at the Advanced Wakefield experiment at CERN. Agreement with existing
measurements and theory has been obtained. Improvements in terms of electron
beam quality and ion beam diagnostic capability, as well as further
applications of such an electron beam, are discussed
The variable finesse locking technique
Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way
A Cross-correlation method to search for gravitational wave bursts with AURIGA and Virgo
We present a method to search for transient GWs using a network of detectors
with different spectral and directional sensitivities: the interferometer Virgo
and the bar detector AURIGA. The data analysis method is based on the
measurements of the correlated energy in the network by means of a weighted
cross-correlation. To limit the computational load, this coherent analysis step
is performed around time-frequency coincident triggers selected by an excess
power event trigger generator tuned at low thresholds. The final selection of
GW candidates is performed by a combined cut on the correlated energy and on
the significance as measured by the event trigger generator. The method has
been tested on one day of data of AURIGA and Virgo during September 2005. The
outcomes are compared to the results of a stand-alone time-frequency
coincidence search. We discuss the advantages and the limits of this approach,
in view of a possible future joint search between AURIGA and one
interferometric detector.Comment: 11 pages, 6 figures, submitted to CQG special issue for Amaldi 7
Proceeding
How Noisy Does a Noisy Miner Have to Be? Amplitude Adjustments of Alarm Calls in an Avian Urban ‘Adapter’
Background: Urban environments generate constant loud noise, which creates a formidable challenge for many animals relying on acoustic communication. Some birds make vocal adjustments that reduce auditory masking by altering, for example, the frequency (kHz) or timing of vocalizations. Another adjustment, well documented for birds under laboratory and natural field conditions, is a noise level-dependent change in sound signal amplitude (the ‘Lombard effect’). To date, however, field research on amplitude adjustments in urban environments has focused exclusively on bird song. Methods: We investigated amplitude regulation of alarm calls using, as our model, a successful urban ‘adapter ’ species, the Noisy miner, Manorina melanocephala. We compared several different alarm calls under contrasting noise conditions. Results: Individuals at noisier locations (arterial roads) alarm called significantly more loudly than those at quieter locations (residential streets). Other mechanisms known to improve sound signal transmission in ‘noise’, namely use of higher perches and in-flight calling, did not differ between site types. Intriguingly, the observed preferential use of different alarm calls by Noisy miners inhabiting arterial roads and residential streets was unlikely to have constituted a vocal modification made in response to sound-masking in the urban environment because the calls involved fell within the main frequency range of background anthropogenic noise. Conclusions: The results of our study suggest that a species, which has the ability to adjust the amplitude of its signals
Diabetes-related molecular signatures in infrared spectra of human saliva
WOS: 000290261500001PubMed ID: 20630088Background: There is an ongoing need for improvements in non-invasive, point-of-care tools for the diagnosis and prognosis of diabetes mellitus. Ideally, such technologies would allow for community screening. Methods: In this study, we employed infrared spectroscopy as a novel diagnostic tool in the prediction of diabetic status by analyzing the molecular and sub-molecular spectral signatures of saliva collected from subjects with diabetes (n = 39) and healthy controls (n = 22). Results: Spectral analysis revealed differences in several major metabolic components - lipid, proteins, glucose, thiocyanate and carboxylate - that clearly demarcate healthy and diseased saliva. The overall accuracy for the diagnosis of diabetes based on infrared spectroscopy was 100% on the training set and 88.2% on the validation set. Therefore, we have established that infrared spectroscopy can be used to generate complex biochemical profiles in saliva and identify several potential diabetes-associated spectral features. Conclusions: Infrared spectroscopy may represent an appropriate tool with which to identify novel diseases mechanisms, risk factors for diabetic complications and markers of therapeutic efficacy. Further study into the potential utility of infrared spectroscopy as diagnostic and prognostic tool for diabetes is warranted
- …