431 research outputs found

    Phantom Membrane Microfluidic Cross-Flow Filtration Device for the Direct Optical Detection of Water Pollutants

    Get PDF
    The diffusion of autonomous sensing platforms capable of a remote large-scale surveillance of environmental water basins is currently limited by the cost and complexity of standard analytical methods. In order to create a new generation of water analysis systems suitable for continuous monitoring of a large number of sites, novel technical solutions for fluid handling and detection are needed. Here we present a microfluidic device hosting a perfluorinated microporous membrane with refractive index similar to that of water, which enables the combination of filtration and label-free sensing of adsorbing substances, mainly pollutants, in environmental water samples. The cross-flow design of the microfluidic device avoids the clogging of the membrane due to particulate, whereas molecules with some hydrophobic moiety contained in the crossing flow are partially retained and their adhesion on the inner surface of the membrane yields an increase of light scattering intensity, which can be easily measured using a simple instrument based on Light Emitting Diode illumination. By cycling sample water and pure water as a reference, we demonstrate the detection of 0.5 microM of a model cationic surfactant and regeneration of the sensing surface. The optical response of the membrane sensor was characterized using a simple theoretical model that enables to quantify the concentration of target molecules from the amplitude and kinetics of the measured binding curves. The device was tested with real water samples containing large amount of environmental particles, without showing clogging of the membrane, and enabling nonspecific quantification of adsorbing substances in a few minutes.This project has received funding from the European Union’s Seventh Framework Programme (FP7) for Research, Technological Development and Demonstration through the NAPES project(grant agreement no. 604241). FBL acknowledges the Ramón y CajalProgramme (Ministerio de Economía y Competitividad), Spain. FBL personally acknowledges to Elkartek (KK-2015/00088) Grant from the Gobierno Vasco and funding support from Gobierno de España, Ministerio de Economia y Competitividad, with Grant No. BIO2016-80417-P and to Marian M. De Pancorbo for letting him to use her laboratory facilities at UPV/EHU. PSA was generously provided byAdhesive Research, Ireland. We thank Aurora Giavazzi for helping in the collection of river water samples

    Coherence Extrapolation for Underwater Ambient Noise

    Get PDF
    This paper considers extrapolation of the vertical coherence of surface-generated oceanic ambient noise to simulate measurements made on a longer sensor array. The extrapolation method consists of projecting the noise coherence measured with a limited aperture array into the domain spanned by prolate spheroidal wave functions, which are an orthogonal basis defined by array parameters and the noise frequency. Using simulated data corresponding to selected multi-layered seabeds as ground truth, the performance of the extrapolation method is explored. Application of the technique is also demonstrated on experimental data

    Records of spiders (Arachnida : Araneae) from the Maltese Islands (Central Mediterranean)

    Get PDF
    Following a brief review of the literature on Maltese Araneae, a list of species which have been confirmed as occurring in the Maltese Islands is given. This list is based on the taxonomic literature and on material in the authors' collections; in the latter case locality and collection data are included. The list comprises 74 species belonging to 21 families. The male palp and female epigyne of a number of species are illustrated.peer-reviewe

    Zinc ions alter morphology and chitin deposition in an ericoid fungus

    Get PDF
    A sterile mycelium PS IV, an ascomycete capable of establishing ericoid mycorrhizas, was used to investigate how zinc ions affect the cellular mechanisms of fungal growth. Asignificant reduction of the fungal biomass was observed in the presence of millimolar zinc concentrations; this mirrored conspicuous changes in hyphal morphology which led to apical swellings and increased branching in the subapical parts. Specific probes for fluorescence and electron microscopy localised chitin, the main cell wall polysaccharide, on the inner part of the fungal wall and on septa in control specimens. In Zn-treated mycelium, hyphal walls were thicker and a more intense chitin labelling was detected on the transverse walls. Aquantitative assay showed a significant increase in the amount of chitin in metal- treated hyphae

    Phantom membrane microfluidic cross-flow filtration device for the direct optical detection of water pollutants

    Get PDF
    The diffusion of autonomous sensing platforms capable of a remote large-scale surveillance of environmental water basins is currently limited by the cost and complexity of standard analytical methods. In order to create a new generation of water analysis systems suitable for continuous monitoring of a large number of sites, novel technical solutions for fluid handling and detection are needed. Here we present a microfluidic device hosting a perfluorinated microporous membrane with refractive index similar to that of water, which enables the combination of filtration and label-free sensing of adsorbing substances, mainly pollutants, in environmental water samples. The cross-flow design of the microfluidic device avoids the clogging of the membrane due to particulate, whereas molecules with some hydrophobic moiety contained in the crossing flow are partially retained and their adhesion on the inner surface of the membrane yields an increase of light scattering intensity, which can be easily measured using a simple instrument based on Light Emitting Diode illumination. By cycling sample water and pure water as a reference, we demonstrate the detection of 0.5 \uce\ubcM of a model cationic surfactant and regeneration of the sensing surface. The optical response of the membrane sensor was characterized using a simple theoretical model that enables to quantify the concentration of target molecules from the amplitude and kinetics of the measured binding curves. The device was tested with real water samples containing large amount of environmental particles, without showing clogging of the membrane, and enabling nonspecific quantification of adsorbing substances in a few minutes

    Type-B monoamine oxidase inhibitors in neurological diseases: clinical applications based on preclinical findings

    Get PDF
    Type-B monoamine oxidase inhibitors, encompassing selegiline, rasagiline, and safinamide, are available to treat Parkinson's disease. These drugs ameliorate motor symptoms and improve motor fluctuation in the advanced stages of the disease. There is also evidence supporting the benefit of type-B monoamine oxidase inhibitors on non-motor symptoms of Parkinson's disease, such as mood deflection, cognitive impairment, sleep disturbances, and fatigue. Preclinical studies indicate that type-B monoamine oxidase inhibitors hold a strong neuroprotective potential in Parkinson's disease and other neurodegenerative diseases for reducing oxidative stress and stimulating the production and release of neurotrophic factors, particularly glial cell line-derived neurotrophic factor, which support dopaminergic neurons. Besides, safinamide may interfere with neurodegenerative mechanisms, counteracting excessive glutamate overdrive in basal ganglia motor circuit and reducing death from excitotoxicity. Due to the dual mechanism of action, the new generation of type-B monoamine oxidase inhibitors, including safinamide, is gaining interest in other neurological pathologies, and many supporting preclinical studies are now available. The potential fields of application concern epilepsy, Duchenne muscular dystrophy, multiple sclerosis, and above all, ischemic brain injury. The purpose of this review is to investigate the preclinical and clinical pharmacology of selegiline, rasagiline, and safinamide in Parkinson's disease and beyond, focusing on possible future therapeutic applications

    A Curriculum for Enhancing Physician Teaching Skills: The Value of Physician-Educator Partnerships

    Get PDF
    Developing as a physician requires an enormous amount of complex training, and quality of instruction greatly affects training outcomes. But while physicians are expected to teach trainees within the clinic, they often do not receive formal training in effective instructional practices. Providing faculty development programs is one way that institutions can help physicians develop teaching skills, but these programs often are developed without the input of educational specialists and not based in educational theory. In this methodology paper, we describe a 5-module curriculum that was developed in a cross-disciplinary collaboration between instructional designers and physician faculty. By merging educational and medical expertise and using adult learning theory with the Charlotte-Danielson educational framework, an essentials for clinical teaching educational endorsement program (ECTEEP) was created as a feature of the institutional curriculum within a large, urban teaching hospital. Here we describe how the program was developed through a physician-educator partnership, outline the program\u27s key content, and highlight essential aspects of successful implementation. The ECTEEP incorporates active learning approaches within an abbreviated format, distilling 5 critical aspects of effective teaching that are relevant to the clinical environment: cultural humility and safe learning environments, instruction practices for engaging learners, instruction and assessment strategies, receiving and giving feedback, and mentorship and coaching. A central feature of the program is that facilitators actively model the teaching behaviors they are conveying, which underscores the critical importance of facilitator preparation and skill. Our curriculum is offered here as a basic template for institutions that may want to establish a program for enhancing physician teaching skill
    corecore