593 research outputs found

    Effects Of Attenuation And Thrombus Age On The Success Of Ultrasound And Microbubble-Mediated Thrombus Dissolution

    Get PDF
    The purpose of this study was to examine the effects of applied mechanical index, incident angle, attenuation and thrombus age on the ability of 2-D vs. 3-D diagnostic ultrasound and microbubbles to dissolve thrombi. A total of 180 occlusive porcine arterial thrombi of varying age (3 or 6 h) were examined in a flow system. A tissue-mimicking phantom of varying thickness (5 to 10 cm) was placed over the thrombosed vessel and the 2-D or 3-D diagnostic transducer aligned with the thrombosed vessel using a positioning system. Diluted lipid-encapsulated microbubbles were infused during ultrasound application. Percent thrombus dissolution (%TD) was calculated by comparison of clot mass before and after treatment. Both 2-D and 3-D-guided ultrasound increased %TD compared with microbubbles alone, but %TD achieved with 6-h-old thrombi was significantly less than 3-h-old thrombi. Thrombus dissolution was achieved at 10 cm tissue-mimicking depths, even without inertial cavitation. In conclusion, diagnostic 2-D or 3-D ultrasound can dissolve thrombi with intravenous nontargeted microbubbles, even at tissue attenuation distances of up to 10 cm. This treatment modality is less effective, however, for older aged thrombi. (E-mail: [email protected]) (C) 2011 World Federation for Ultrasound in Medicine & Biology

    Decay of scalar variance in isotropic turbulence in a bounded domain

    Full text link
    The decay of scalar variance in isotropic turbulence in a bounded domain is investigated. Extending the study of Touil, Bertoglio and Shao (2002; Journal of Turbulence, 03, 49) to the case of a passive scalar, the effect of the finite size of the domain on the lengthscales of turbulent eddies and scalar structures is studied by truncating the infrared range of the wavenumber spectra. Analytical arguments based on a simple model for the spectral distributions show that the decay exponent for the variance of scalar fluctuations is proportional to the ratio of the Kolmogorov constant to the Corrsin-Obukhov constant. This result is verified by closure calculations in which the Corrsin-Obukhov constant is artificially varied. Large-eddy simulations provide support to the results and give an estimation of the value of the decay exponent and of the scalar to velocity time scale ratio

    Derivation of transient relativistic fluid dynamics from the Boltzmann equation

    Full text link
    In this work we present a general derivation of relativistic fluid dynamics from the Boltzmann equation using the method of moments. The main difference between our approach and the traditional 14-moment approximation is that we will not close the fluid-dynamical equations of motion by truncating the expansion of the distribution function. Instead, we keep all terms in the moment expansion. The reduction of the degrees of freedom is done by identifying the microscopic time scales of the Boltzmann equation and considering only the slowest ones. In addition, the equations of motion for the dissipative quantities are truncated according to a systematic power-counting scheme in Knudsen and inverse Reynolds number. We conclude that the equations of motion can be closed in terms of only 14 dynamical variables, as long as we only keep terms of second order in Knudsen and/or inverse Reynolds number. We show that, even though the equations of motion are closed in terms of these 14 fields, the transport coefficients carry information about all the moments of the distribution function. In this way, we can show that the particle-diffusion and shear-viscosity coefficients agree with the values given by the Chapman-Enskog expansion.Comment: 27 page

    Aortoiliac hemodynamic and morphologic adaptation to chronic spinal cord injury

    Get PDF
    BackgroundReduced lower limb blood flow and resistive hemodynamic conditions potentially promote aortic inflammation and aneurysmal degeneration. We used abdominal ultrasonography, magnetic resonance imaging, and computational flow modeling to determine the relationship between reduced infrarenal aortic blood flow in chronic spinal cord injury (SCI) subjects and risk for abdominal aortic aneurysm (AAA) disease.MethodsAortic diameter in consecutive SCI subjects (n = 123) was determined via transabdominal ultrasonography. Aortic anatomic and physiologic data were acquired via magnetic resonance angiography (MRA; n = 5) and cine phase-contrast magnetic resonance flow imaging (n = 4) from SCI subjects whose aortic diameter was less than 3.0 cm by ultrasonography. Computational flow models were constructed from magnetic resonance data sets. Results were compared with those obtained from ambulatory control subjects (ultrasonography, n = 129; MRA/phase-contrast magnetic resonance flow imaging, n = 6) who were recruited at random from a larger pool of risk factor–matched individuals without known AAA disease.ResultsAge, sex distribution, and smoking histories were comparable between the SCI and control groups. In the SCI group, time since injury averaged 26 ± 13 years (mean ± SD). Aortic diameter was larger (P < .01), and the prevalence of large (≥2.5 cm; P < .01) or aneurysmal (≥3.0 cm; P < .05) aortas was greater in SCI subjects. Paradoxically, common iliac artery diameters were reduced in SCI subjects (<1.0 cm; 48% SCI vs 26% control; P < .0001). Focal preaneurysmal enlargement was noted in four of five SCI subjects by MRA. Flow modeling revealed normal flow volume, biphasic and reduced oscillatory flow, slower pressure decay, and reduced wall shear stress in the SCI infrarenal aorta.ConclusionsCharacteristic aortoiliac hemodynamic and morphologic adaptations occur in response to chronic SCI. Slower aortic pressure decay and reduced wall shear stress after SCI may contribute to mural degeneration, enlargement, and an increased prevalence of AAA disease

    Airflow and Particle Deposition Simulations in Health and Emphysema: From In Vivo to In Silico Animal Experiments

    Get PDF
    International audienceImage-based in-silico modeling tools provide detailed velocity and particle deposition data. However, care must be taken when prescribing boundary conditions to model lung physiology in health or disease, such as in emphysema. In this study, the respiratory resistance and compliance were obtained by solving an inverse problem; a 0D global model based on healthy and emphysematous rat experimental data. Multi-scale CFD simulations were performed by solving the 3D Navier Stokes equations in an MRI-derived rat geometry coupled to a 0D model. Particles with 0.95 um diameter were tracked and their distribution in the lung was assessed. Seven 3D-0D simulations were performed: healthy, homogeneous, and five heterogeneous emphysema cases. Compliance (C) was significantly higher (p = 0.04) in the emphysematous rats (C = 0.37 +/- 0.14 cm^3 / cmH_2O) compared to the healthy rats (C = 0.25 +/- 0 0.04 cm^3 / cmH_2O), while the resistance remained unchanged (p = 0.83). There were increases in airflow, particle deposition in the 3D model, and particle delivery to the diseased regions for the heterogeneous cases compared to the homogeneous cases. The results highlight the importance of multi-scale numerical simulations to study airflow and particle distribution in healthy and diseased lungs. The effect of particle size and gravity were studied. Once available, these in-silico predictions may be compared to experimental deposition data

    Predictive modeling of the virtual Hemi-Fontan operation for second stage single ventricle palliation: Two patient-specific cases

    Get PDF
    Single ventricle hearts are congenital cardiovascular defects in which the heart has only one functional pumping chamber. The treatment for these conditions typically requires a three-staged operative process where Stage 1 is typically achieved by a shunt between the systemic and pulmonary arteries, and Stage 2 by connecting the superior venous return to the pulmonary circulation. Surgically, the Stage 2 circulation can be achieved through a procedure called the Hemi-Fontan, which reconstructs the right atrium and pulmonary artery to allow for an enlarged confluence with the superior vena cava. Based on pre-operative data obtained from two patients prior to Stage 2 surgery, we developed two patient-specific multi-scale computational models, each including the 3D geometrical model of the surgical junction constructed from magnetic resonance imaging, and a closed-loop systemic lumped-parameter network derived from clinical measurements. “Virtual” Hemi-Fontan surgery was performed on the 3D model with guidance from clinical surgeons, and a corresponding multi-scale simulation predicts the patient\u27s post-operative hemodynamic and physiologic conditions. For each patient, a post-operative active scenario with an increase in the heart rate (HR) and a decrease in the pulmonary and systemic vascular resistance (PVR and SVR) was also performed. Results between the baseline and this “active” state were compared to evaluate the hemodynamic and physiologic implications of changing conditions. Simulation results revealed a characteristic swirling vortex in the Hemi-Fontan in both patients, with flow hugging the wall along the SVC to Hemi-Fontan confluence. One patient model had higher levels of swirling, recirculation, and flow stagnation. However, in both models, the power loss within the surgical junction was less than 13% of the total power loss in the pulmonary circulation, and less than 2% of the total ventricular power. This implies little impact of the surgical junction geometry on the SVC pressure, cardiac output, and other systemic parameters. In contrast, varying HR, PVR, and SVR led to significant changes in theses clinically relevant global parameters. Adopting a work-flow of customized virtual planning of the Hemi-Fontan procedure with patient-specific data, this study demonstrates the ability of multi-scale modeling to reproduce patient specific flow conditions under differing physiological states. Results demonstrate that the same operation performed in two different patients can lead to different hemodynamic characteristics, and that modeling can be used to uncover physiologic changes associated with different clinical conditions

    Rabbit Knee Joint Biomechanics: Motion Analysis and Modeling of Forces during Hopping

    Full text link
    Although the rabbit hindlimb has been commonly used as an experimental animal model for studies of osteoarthritis, bone growth and fracture healing, the in vivo biomechanics of the rabbit knee joint have not been quantified. The purpose of this study was to investigate the kinematic and kinetic patterns during hopping of the adult rabbit, and to develop a model to estimate the joint contact force distribution between the tibial plateaus. Force platform data and three-dimensional motion analysis using infrared markers mounted on intracortical bone pins were combined to calculate the knee and ankle joint intersegmental forces and moments. A statically determinate model was developed to predict muscle, ligament and tibiofemoral joint contact forces during the stance phase of hopping. Variations in hindlimb kinematics permitted the identification of two landing patterns, that could be distinguished by variations in the magnitude of the external knee abduction moment. During hopping, the prevalence of an external abduction moment led to the prediction of higher joint contact forces passing through the lateral compartment as compared to the medial compartment of the knee joint. These results represent critical data on the in vivo biomechanics of the rabbit knee joint, which allow for comparisons to both other experimental animal models and the human knee, and may provide further insight into the relationships between mechanical loading, osteoarthritis, bone growth, and fracture healing

    Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography

    Get PDF
    BACKGROUND: Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. METHODS: We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. RESULTS: There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. CONCLUSION: Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting

    Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation

    Get PDF
    A novel multiscale mathematical and computational model of the pulmonary circulation is presented and used to analyse both arterial and venous pressure and flow. This work is a major advance over previous studies by Olufsen et al. (Ann Biomed Eng 28:1281–1299, 2012) which only considered the arterial circulation. For the first three generations of vessels within the pulmonary circulation, geometry is specified from patient-specific measurements obtained using magnetic resonance imaging (MRI). Blood flow and pressure in the larger arteries and veins are predicted using a nonlinear, cross-sectional-area-averaged system of equations for a Newtonian fluid in an elastic tube. Inflow into the main pulmonary artery is obtained from MRI measurements, while pressure entering the left atrium from the main pulmonary vein is kept constant at the normal mean value of 2 mmHg. Each terminal vessel in the network of ‘large’ arteries is connected to its corresponding terminal vein via a network of vessels representing the vascular bed of smaller arteries and veins. We develop and implement an algorithm to calculate the admittance of each vascular bed, using bifurcating structured trees and recursion. The structured-tree models take into account the geometry and material properties of the ‘smaller’ arteries and veins of radii ≥ 50 μ m. We study the effects on flow and pressure associated with three classes of pulmonary hypertension expressed via stiffening of larger and smaller vessels, and vascular rarefaction. The results of simulating these pathological conditions are in agreement with clinical observations, showing that the model has potential for assisting with diagnosis and treatment for circulatory diseases within the lung
    corecore