20 research outputs found

    Thermal runaway of metal nano-tips during intense electron emission

    Get PDF
    When an electron emitting tip is subjected to very high electric fields, plasma forms even under ultra high vacuum conditions. This phenomenon, known as vacuum arc, causes catastrophic surface modifications and constitutes a major limiting factor not only for modern electron sources, but also for many large-scale applications such as particle accelerators, fusion reactors etc. Although vacuum arcs have been studied thoroughly, the physical mechanisms that lead from intense electron emission to plasma ignition are still unclear. In this article, we give insights to the atomic scale processes taking place in metal nanotips under intense field emission conditions. We use multi-scale atomistic simulations that concurrently include field-induced forces, electron emission with finite-size and space-charge effects, Nottingham and Joule heating. We find that when a sufficiently high electric field is applied to the tip, the emission-generated heat partially melts it and the field-induced force elongates and sharpens it. This initiates a positive feedback thermal runaway process, which eventually causes evaporation of large fractions of the tip. The reported mechanism can explain the origin of neutral atoms necessary to initiate plasma, a missing key process required to explain the ignition of a vacuum arc. Our simulations provide a quantitative description of in the conditions leading to runaway, which shall be valuable for both field emission applications and vacuum arc studies.Peer reviewe

    Ab initio calculation of field emission from metal surfaces with atomic-scale defects

    Get PDF
    In this work we combine density functional theory and quantum transport calculations to study the influence of atomic-scale defects on the work function and field emission characteristics of metal surfaces. We develop a general methodology for the calculation of the field emitted current density from nanofeatured surfaces, which is then used to study specific defects on a Cu(111) surface. Our results show that the inclusion of a defect can significantly locally enhance the field emitted current density. However, this increase is attributed solely to the decrease of the work function due to the defect, with the effective field enhancement being minute. Finally, the Fowler-Nordheim equation is found to be valid when the modified value for the work function is used, with only an approximately constant factor separating the computed currents from those predicted by the Fowler-Nordheim equation.Peer reviewe

    Scale invariance of a diodelike tunnel junction

    Get PDF
    We measure the current vs voltage (I-V) characteristics of a diodelike tunnel junction consisting of a sharp metallic tip placed at a variable distance d from a planar collector and emitting electrons via electric-field assisted emission. All curves collapse onto one single graph when I is plotted as a function of the single scaling variable Vd^{-\lambda}, d being varied from a few mm to a few nm, i.e., by about six orders of magnitude. We provide an argument that finds the exponent {\lambda} within the singular behavior inherent to the electrostatics of a sharp tip. A simulation of the tunneling barrier for a realistic tip reproduces both the scaling behavior and the small but significant deviations from scaling observed experimentally.Comment: 6 pages, 6 figures. Accepted for publication in Physical Review

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF
    The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e+ee^+e^- collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years
    corecore