9 research outputs found

    HST Measurements of the Expansion of NGC 6543: Parallax Distance and Nebular Evolution

    Get PDF
    The optical expansion parallax of NGC 6543 has been detected and measured using two epochs of HST images separated by a time baseline of only three years. We have utilized three separate methods of deriving the angular expansion of bright fiducials, the results of which are in excellent agreement. We combine our angular expansion estimates with spectroscopically obtained expansion velocities to derive a distance to NGC 6543 of 1001±\pm269 pc. The deduced kinematic age of the inner bright core of the nebula is 1039±\pm259 years; however, the kinematic age of the polar caps that surround the core is larger - perhaps the result of deceleration or earlier mass ejection. The morphology and expansion patterns of NGC 6543 provide insight into a complex history of axisymmetric, interacting stellar mass ejections.Comment: Accepted for publication in AJ. 18 pages. 6 figure

    Prostate bed motion during intensity-modulated radiotherapy treatment.

    No full text
    PURPOSE: Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders. METHODS AND MATERIALS: The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center. RESULTS: At localization, prostate bed displacement relative to bony anatomy exceeded 5 mm in 9% of fractions in the anterior-posterior (A-P) direction and 21% of fractions in the superior-inferior (S-I) direction. The three-dimensional vector length from skin marks to Calypso alignment exceeded 1 cm in 24% of all 652 fractions with available setup data. During treatment, the target exceeded the 5-mm tracking limit for at least 30 sec in 11% of all fractions, generally in the A-P or S-I direction. In the A-P direction, target motion was twice as likely to move posteriorly, toward the rectum, than anteriorly. Fifteen percent of all treatments were interrupted for repositioning, and 70% of patients were repositioned at least once during their treatment course. CONCLUSION: Set-up errors and motion of the prostatic fossa during radiotherapy are nontrivial, leading to potential undertreatment of target and excess normal tissue toxicity if not taken into account during treatment planning. Localization and real-time tracking of the prostate bed via implanted Calypso transponders can be used to improve the accuracy of plan delivery

    Five-year results of whole breast intensity modulated radiation therapy for the treatment of early stage breast cancer: the Fox Chase Cancer Center experience.

    No full text
    PURPOSE: To report the 5-year outcomes using whole-breast intensity-modulated radiation therapy (IMRT) for the treatment of early-stage-breast cancer at the Fox Chase Cancer Center. METHODS AND MATERIALS: A total of 946 women with early-stage breast cancer (stage 0, I, or II) were treated with IMRT after surgery with or without systemic therapy from 2003-2010. Whole-breast radiation was delivered via an IMRT technique with a median whole-breast radiation dose of 46 Gy and median tumor bed boost of 14 Gy. Endpoints included local-regional recurrence, cosmesis, and late complications. RESULTS: With a median follow-up of 31 months (range, 1-97 months), there were 12 ipsilateral breast tumor recurrences (IBTR) and one locoregional recurrence. The 5-year actuarial IBTR and locoregional recurrence rates were 2.0% and 2.4%. Physician-reported cosmestic outcomes were available for 645 patients: 63% were considered excellent , 33% good , and \u3c1.5% fair/poor . For physician-reported cosmesis, boost doses≥16 Gy, breast size\u3e900 cc, or boost volumes\u3e34 cc were significantly associated with a fair/poor cosmetic outcome. Fibrosis, edema, erythema, and telangectasia were also associated with fair/poor physician-reported cosmesis; erythema and telangectasia remained significant on multivariate analysis. Patient-reported cosmesis was available for 548 patients, and 33%, 50%, and 17% of patients reported excellent , good , and fair/poor cosmesis, respectively. The use of a boost and increased boost volume: breast volume ratio were significantly associated with fair/poor outcomes. No parameter for patient-reported cosmesis was significant on multivariate analysis. The chances of experiencing a treatment related effect was significantly associated with a boost dose≥16 Gy, receipt of chemotherapy and endocrine therapy, large breast size, and electron boost energy. CONCLUSIONS: Whole-breast IMRT is associated with very low rates of local recurrence at 5 years, 83%-98% good/excellent cosmetic outcomes, and minimal chronic toxicity, including late fibrosis

    Stamp test delivers message on erectile dysfunction after high-dose intensity-modulated radiotherapy for prostate cancer.

    No full text
    OBJECTIVE: To evaluate erectile function after high-dose radiotherapy for prostate cancer using the International Index of Erectile Function, Expanded Prostate Cancer Index Composite, and stamp test. METHODS: Men with favorable and intermediate-risk prostate cancer were assigned to receive prostate intensity-modulated radiotherapy (IMRT) versus an erectile tissue-sparing IMRT technique in a Phase III randomized, prospective study. The stamp test and International Index of Erectile Function and Expanded Prostate Cancer Index Composite questionnaires were completed at baseline and 6 months, 1 year, and 2 years after IMRT. The Sexual Health Inventory for Men scores were abstracted from the International Index of Erectile Function questionnaire. A partner questionnaire, designated IIEF-P, modeled after the International Index of Erectile Function questionnaire but from the perspective of the partner, was also collected. RESULTS: The data from 94 men who were enrolled in the trial and who had completed ≥1 questionnaire or 1 stamp test were analyzed. The median age of the patient population was 62.5 years. The median radiation dose was 76 Gy (range 74-80). At 6 months and 1 year after high-dose IMRT, a positive stamp result correlated significantly with the median Expanded Prostate Cancer Index Composite sexual summary, sexual function, and bother subscale scores. Additionally, 6 months after IMRT, the stamp test correlated with the median International Index of Erectile Function, International Index of Erectile Function sexual function domain, and Sexual Health Inventory for Men scores. Robust concordance for the International Index of Erectile Function and Sexual Health Inventory for Men scores was appreciated between responding patient and partner pairs. CONCLUSION: Nocturnal tumescence, as indicated by a positive stamp test, correlated well with established quality of life questionnaires after IMRT. The stamp test should strongly be considered as an objective measure of erectile function in future studies of erectile dysfunction in patients with prostate cancer

    Stamp Test Delivers Message on Erectile Dysfunction After High-dose Intensity-modulated Radiotherapy for Prostate Cancer

    No full text
    OBJECTIVES: To evaluate erectile function following high dose radiotherapy for prostate cancer using the international index of erectile function (IIEF), expanded prostate cancer index composite (EPIC), and stamp test. METHODS: Men with favorable and intermediate risk prostate cancer were assigned to receive prostate intensity modulated radiotherapy (IMRT) vs. an erectile tissue-sparing IMRT technique on a phase III randomized prospective study. The stamp test, IIEF, and EPIC questionnaires were completed at baseline, 6 months, one year, and two years after IMRT. Sexual Health Inventory for Men (SHIM) scores were abstracted from IIEF questionnaires. A partner questionnaire, designated IIEF-P, modeled after the IIEF but from the perspective of the partner, was collected. RESULTS: Ninety four men enrolled on the trial who completed at least one questionnaire or one stamp test were analyzed. The median age of the patient population was 62.5 years. The median RT dose was 76 Gy (range: 74–80 Gy). At 6-months and one year after high-dose IMRT, a positive stamp result significantly correlated with median EPIC sexual summary, sexual function (EF), and bother subscale scores. Additionally, 6-months after IMRT the stamp test correlated with median IIEF, IIEF EF domain, and SHIM scores. Robust concordance for the IIEF and SHIM results was appreciated between responding patients: partner pairs. CONCLUSIONS: Nocturnal tumescence indicated by a positive stamp test correlates well with established quality of life questionnaires after IMRT. The stamp test should strongly be considered as an objective measure of erectile function in future studies of ED in prostate cancer patients
    corecore