    Interventions to reduce low-value imaging: a systematic review of interventions and outcomes

    Get PDF
    Background It is estimated that 20-50% of all radiological examinations are of low value. Many attempts have been made to reduce the use of low-value imaging. However, the comparative effectiveness of interventions to reduce low-value imaging is unclear. Thus, the objective of this systematic review was to provide an overview and evaluate the outcomes of interventions aimed at reducing low-value imaging. Methods An electronic database search was completed in Medline - Ovid, Embase-Ovid, Scopus, and Cochrane Library for citations between 2010 and 2020. The search was built from medical subject headings for Diagnostic imaging/Radiology, Health service misuse or medical overuse, and Health planning. Keywords were used for the concept of reduction and avoidance. Reference lists of included articles were also hand-searched for relevant citations. Only articles written in English, German, Danish, Norwegian, Dutch, and Swedish were included. The Mixed Methods Appraisal Tool was used to appraise the quality of the included articles. A narrative synthesis of the final included articles was completed. Results The search identified 15,659 records. After abstract and full-text screening, 95 studies of varying quality were included in the final analysis, containing 45 studies found through hand-searching techniques. Both controlled and uncontrolled before-and-after studies, time series, chart reviews, and cohort studies were included. Most interventions were aimed at referring physicians. Clinical practice guidelines (n = 28) and education (n = 28) were most commonly evaluated interventions, either alone or in combination with other components. Multi-component interventions were often more effective than single-component interventions showing a reduction in the use of low-value imaging in 94 and 74% of the studies, respectively. The most addressed types of imaging were musculoskeletal (n = 26), neurological (n = 23) and vascular (n = 16) imaging. Seventy-seven studies reported reduced low-value imaging, while 3 studies reported an increase. Conclusions Multi-component interventions that include education were often more effective than single-component interventions. The contextual and cultural factors in the health care systems seem to be vital for successful reduction of low-value imaging. Further research should focus on assessing the impact of the context in interventions reducing low-value imaging and how interventions can be adapted to different contexts.Analysis and support of clinical decision makin

    Increasing source to image distance for AP pelvis imaging – impact on radiation dose and image quality

    Get PDF
    Aim: A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods: Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results: Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p ÂĽ 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion: For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality

    Fluid challenges in intensive care: the FENICE study A global inception cohort study

    Get PDF
    Fluid challenges (FCs) are one of the most commonly used therapies in critically ill patients and represent the cornerstone of hemodynamic management in intensive care units. There are clear benefits and harms from fluid therapy. Limited data on the indication, type, amount and rate of an FC in critically ill patients exist in the literature. The primary aim was to evaluate how physicians conduct FCs in terms of type, volume, and rate of given fluid; the secondary aim was to evaluate variables used to trigger an FC and to compare the proportion of patients receiving further fluid administration based on the response to the FC.This was an observational study conducted in ICUs around the world. Each participating unit entered a maximum of 20 patients with one FC.2213 patients were enrolled and analyzed in the study. The median [interquartile range] amount of fluid given during an FC was 500 ml (500-1000). The median time was 24 min (40-60 min), and the median rate of FC was 1000 [500-1333] ml/h. The main indication for FC was hypotension in 1211 (59 %, CI 57-61 %). In 43 % (CI 41-45 %) of the cases no hemodynamic variable was used. Static markers of preload were used in 785 of 2213 cases (36 %, CI 34-37 %). Dynamic indices of preload responsiveness were used in 483 of 2213 cases (22 %, CI 20-24 %). No safety variable for the FC was used in 72 % (CI 70-74 %) of the cases. There was no statistically significant difference in the proportion of patients who received further fluids after the FC between those with a positive, with an uncertain or with a negatively judged response.The current practice and evaluation of FC in critically ill patients are highly variable. Prediction of fluid responsiveness is not used routinely, safety limits are rarely used, and information from previous failed FCs is not always taken into account

    Characterizing and quantifying low-value diagnostic imaging internationally: a scoping review

    No full text
    Background Inappropriate and wasteful use of health care resources is a common problem, constituting 10-34% of health services spending in the western world. Even though diagnostic imaging is vital for identifying correct diagnoses and administrating the right treatment, low-value imaging-in which the diagnostic test confers little to no clinical benefit-is common and contributes to inappropriate and wasteful use of health care resources. There is a lack of knowledge on the types and extent of low-value imaging. Accordingly, the objective of this study was to identify, characterize, and quantify the extent of low-value diagnostic imaging examinations for adults and children. Methods A scoping review of the published literature was performed. Medline-Ovid, Embase-Ovid, Scopus, and Cochrane Library were searched for studies published from 2010 to September 2020. The search strategy was built from medical subject headings (Mesh) for Diagnostic imaging/Radiology OR Health service misuse/Medical overuse OR Procedures and Techniques Utilization/Facilities and Services Utilization. Articles in English, German, Dutch, Swedish, Danish, or Norwegian were included. Results A total of 39,986 records were identified and, of these, 370 studies were included in the final synthesis. Eighty-four low-value imaging examinations were identified. Imaging of atraumatic pain, routine imaging in minor head injury, trauma, thrombosis, urolithiasis, after thoracic interventions, fracture follow-up and cancer staging/follow-up were the most frequently identified low-value imaging examinations. The proportion of low-value imaging varied between 2 and 100% inappropriate or unnecessary examinations. Conclusions A comprehensive list of identified low-value radiological examinations for both adults and children are presented. Future research should focus on reasons for low-value imaging utilization and interventions to reduce the use of low-value imaging internationally. Systematic review registration: PROSPERO: CRD42020208072

    Increasing source to image distance for AP pelvis imaging: impact on radiation dose and image quality

    No full text
    Aim - A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods - Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results - Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p = 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion - For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality
    corecore