630 research outputs found
Experimental Evaluation of Non-Composite Shallow Press-Brake-Formed Steel Tub Girders
The Short Span Steel Bridge Alliance (SSSBA) is a group of bridge industry leaders (including steel manufacturers, fabricators, service centers, coaters, researchers, and representatives of related associations and government organizations) who have joined together to provide educational information on the design and construction of short-span steel bridges in installations up to 140 feet in length (Michaelson, 2014). From within the SSSBA technical working group, a shallow press-brake-formed steel tub girder was developed. This new technology consists of cold-bending standard mill plate width and thicknesses to form a trapezoidal box girder. By eliminating the need to cut and weld plates together, the system proves to be an economical and rapid construction option. The steel plate can either be weathering steel or galvanized steel, each an economical option.;The originally-proposed system consisted of a reinforced concrete deck cast on the girder in the fabrication shop, forming a composite modular unit once cured. The composite unit would then be shipped to the construction site to be installed. However, the option of implementing a cast-in-place deck must be explored. A critical design stage for these girders occurs during pouring of the concrete deck, when the non-composite steel section must support the construction load, including the wet concrete. During this period, the top flanges are in compression and the system is susceptible to torsional buckling and deflection phenomena. Therefore, for a cast-in-place deck option, the non-composite stability and behavior of tub girders needs to be further evaluated.;The scope of this project was to develop a complete understanding of the stability and behavior of non-composite press-brake-formed tub girders for short span bridge applications. This was performed in four stages. A complete literature review focusing on previous studies relating to non-composite trapezoidal steel tub girder behavior was conducted. Destructive flexural testing was then performed on two non-composite specimens to assess the ultimate capacity of the system. Next, nonlinear finite element models were developed and benchmarked against experimental data. Results of the experimental and FEA modeling are used to determine bracing requirements for the non-composite press-brake-formed tub girders to improve their torsional response
Impacts of Psychological Stress on Osteoporosis: Clinical Implications and Treatment Interactions
The significant biochemical and physiological effects of psychological stress are beginning to be recognized as exacerbating common diseases, including osteoporosis. This review discusses the current evidence for psychological stress-associated mental health disorders as risk factors for osteoporosis, the mechanisms that may link these conditions, and potential implications for treatment. Traditional, alternative, and adjunctive therapies are discussed. This review is not intended to provide therapeutic recommendations, but, rather, the goal of this review is to delineate potential interactions of psychological stress and osteoporosis and to highlight potential multi-system implications of pharmacological interventions. Review of the current literature identifies several potentially overlapping mechanistic pathways that may be of interest (e.g., glucocorticoid signaling, insulin-like growth factor signaling, serotonin signaling) for further basic and clinical research. Current literature also supports the potential for cross-effects of therapeutics for osteoporosis and mental health disorders. While studies examining a direct link between osteoporosis and chronic psychological stress are limited, the studies reviewed herein suggest that a multi-factorial, personalized approach should be considered for improved patient outcomes in populations experiencing psychological stress, particularly those at high-risk for development of osteoporosis
Geographic Coincidence of Increased Malaria Transmission Hazard and Vulnerability Occurring at the Periphery of two Tanzanian Villages.
The goal of malaria elimination necessitates an improved understanding of any fine-scale geographic variations in transmission risk so that complementary vector control tools can be integrated into current vector control programmes as supplementary measures that are spatially targeted to maximize impact upon residual transmission. This study examines the distribution of host-seeking malaria vectors at households within two villages in rural Tanzania. Host-seeking mosquitoes were sampled from 72 randomly selected households in two villages on a monthly basis throughout 2008 using CDC light-traps placed beside occupied nets. Spatial autocorrelation in the dataset was examined using the Moran's I statistic and the location of any clusters was identified using the Getis-Ord Gi* statistic. Statistical associations between the household characteristics and clusters of mosquitoes were assessed using a generalized linear model for each species. For both Anopheles gambiae sensu lato and Anopheles funestus, the density of host-seeking females was spatially autocorrelated, or clustered. For both species, houses with low densities were clustered in the semi-urban village centre while houses with high densities were clustered in the periphery of the villages. Clusters of houses with low or high densities of An. gambiae s.l. were influenced by the number of residents in nearby houses. The occurrence of high-density clusters of An. gambiae s.l. was associated with lower elevations while An. funestus was also associated with higher elevations. Distance from the village centre was also positively correlated with the number of household occupants and having houses constructed with open eaves. The results of the current study highlight that complementary vector control tools could be most effectively targeted to the periphery of villages where the households potentially have a higher hazard (mosquito densities) and vulnerability (open eaves and larger households) to malaria infection
Limited domestic introgression in a final refuge of the wild pigeon
Domesticated animals have been culturally and economically important
throughout history. Many of their ancestral lineages are extinct or genetically en dangered following hybridization with domesticated relatives. Consequently,
they have been understudied compared to the ancestral lineages of domestic
plants. The domestic pigeon Columba livia, which was pivotal in Darwin’s studies,
has maintained outsized cultural significance. Its role as a model organism spans
the fields of behavior, genetics, and evolution. Domestic pigeons have hybridized
with their progenitor, the Rock Dove, rendering the latter of dubious genetic sta tus. Here, we use genomic and morphological data from the putative Rock Doves
of the British Isles to identify relictual undomesticated populations. We reveal
that Outer Hebridean Rock Doves have experienced minimal levels of introgres sion. Our results outline the contemporary status of these wild pigeons, high lighting the role of hybridization in the homogenization of genetic lineages.publishedVersio
Tumor Susceptibility Gene 101 (TSG101) Is a Novel Binding-Partner for the Class II Rab11-FIPs
The Rab11-FIPs (Rab11-family interacting proteins; henceforth, FIPs) are a family of Rab11a/Rab11b/Rab25 GTPase effector proteins implicated in an assortment of intracellular trafficking processes. Through proteomic screening, we have identified TSG101 (tumor susceptibility gene 101), a component of the ESCRT-I (endosomal sorting complex required for transport) complex, as a novel FIP4-binding protein, which we find can also bind FIP3. We show that α-helical coiled-coil regions of both TSG101 and FIP4 mediate the interaction with the cognate protein, and that point mutations in the coiled-coil regions of both TSG101 and FIP4 abrogate the interaction. We find that expression of TSG101 and FIP4 mutants cause cytokinesis defects, but that the TSG101-FIP4 interaction is not required for localisation of TSG101 to the midbody/Flemming body during abscission. Together, these data suggest functional overlap between Rab11-controlled processes and components of the ESCRT pathway
Controlled production of atomic oxygen and nitrogen in a pulsed radio-frequency atmospheric-pressure plasma
International audienceRadio-frequency driven atmospheric pressure plasmas are efficient sources for the production of reactive species at ambient pressure and close to room temperature. Pulsing the radio-frequency power input provides additional control over species production and gas temperature. Here, we demonstrate the controlled production of highly reactive atomic oxygen and nitrogen in a pulsed radio-frequency ( ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn001.gif] 13.56 MHz) atmospheric-pressure plasma, operated with a small ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn002.gif] 0.1 % air-like admixture ( ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn003.gif] \rm N_2 / ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn004.gif] \rm O_2 at ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn005.gif] 4:1 ) through variations in the duty cycle. Absolute densities of atomic oxygen and nitrogen are determined through vacuum-ultraviolet absorption spectroscopy using the DESIRS beamline at the SOLEIL synchrotron coupled with a high resolution Fourier-transform spectrometer. The neutral-gas temperature is measured using nitrogen molecular optical emission spectroscopy. For a fixed applied-voltage amplitude (234?V), varying the pulse duty cycle from 10% to 100% at a fixed 10?kHz pulse frequency enables us to regulate the densities of atomic oxygen and nitrogen over the ranges of ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn006.gif] (0.18±0.03) ? ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn007.gif] (3.7±0.1)× 10^20 ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn008.gif] \rm m^-3 and ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn009.gif] (0.2±0.06) ? ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn010.gif] (4.4±0.8) × 10^19 ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn011.gif] \rm m^-3 , respectively. The corresponding 11?K increase in the neutral-gas temperature with increased duty cycle, up to a maximum of ##IMG## [http://ej.iop.org/images/0022-3727/50/45/455204/daa8da2ieqn012.gif] (314±4) K, is relatively small. This additional degree of control, achieved through regulation of the pulse duty cycle and time-averaged power, could be of particular interest for prospective biomedical applications
The Prevalence and Influence of New or Worsened Neck Pain After a Sport-Related Concussion in Collegiate Athletes: A Study From the CARE Consortium
BACKGROUND: Neck pain in a concussion population is an emerging area of study that has been shown to have a negative influence on recovery. This effect has not yet been studied in collegiate athletes.
HYPOTHESIS: New or worsened neck pain is common after a concussion (>30%), negatively influences recovery, and is associated with patient sex and level of contact in sport.
STUDY DESIGN: Cohort study; Level of evidence, 2.
METHODS: Varsity-level athletes from 29 National Collegiate Athletic Association member institutions as well as nonvarsity sport athletes at military service academies were eligible for enrollment. Participants completed a preseason baseline assessment and follow-up assessments at 6 and 24 to 48 hours after a concussion, when they were symptom-free, and when they returned to unrestricted play. Data collection occurred between January 2014 and September 2018.
RESULTS: A total of 2163 injuries were studied. New or worsened neck pain was reported with 47.0% of injuries. New or worsened neck pain was associated with patient sex (higher in female athletes), an altered mental status after the injury, the mechanism of injury, and what the athlete collided with. The presence of new/worsened neck pain was associated with delayed recovery. Those with new or worsened neck pain had 11.1 days of symptoms versus 8.8 days in those without (P < .001). They were also less likely to have a resolution of self-reported symptoms in ≤7 days (P < .001). However, the mean duration of the return-to-play protocol was not significantly different for those with new or worsened neck pain (7.5 ± 7.7 days) than those without (7.4 ± 8.3 days) (P = .592).
CONCLUSION: This novel study shows that neck pain was common in collegiate athletes sustaining a concussion, was influenced by many factors, and negatively affected recovery
Evaluation of alternative mosquito sampling methods for malaria vectors in Lowland South - East Zambia.
Sampling malaria vectors and measuring their biting density is of paramount importance for entomological surveys of malaria transmission. Human landing catch (HLC) has been traditionally regarded as a gold standard method for surveying human exposure to mosquito bites. However, due to the risk of human participant exposure to mosquito-borne parasites and viruses, a variety of alternative, exposure-free trapping methods were compared in lowland, south-east Zambia. Centres for Disease Control and Prevention miniature light trap (CDC-LT), Ifakara Tent Trap model C (ITT-C), resting boxes (RB) and window exit traps (WET) were all compared with HLC using a 3 × 3 Latin Squares design replicated in 4 blocks of 3 houses with long lasting insecticidal nets, half of which were also sprayed with a residual deltamethrin formulation, which was repeated for 10 rounds of 3 nights of rotation each during both the dry and wet seasons. The mean catches of HLC indoor, HLC outdoor, CDC-LT, ITT-C, WET, RB indoor and RB outdoor, were 1.687, 1.004, 3.267, 0.088, 0.004, 0.000 and 0.008 for Anopheles quadriannulatus Theobald respectively, and 7.287, 6.784, 10.958, 5.875, 0.296, 0.158 and 0.458, for An. funestus Giles, respectively. Indoor CDC-LT was more efficient in sampling An. quadriannulatus and An. funestus than HLC indoor (Relative rate [95% Confidence Interval] = 1.873 [1.653, 2.122] and 1.532 [1.441, 1.628], respectively, P < 0.001 for both). ITT-C was the only other alternative which had comparable sensitivity (RR = 0.821 [0.765, 0.881], P < 0.001), relative to HLC indoor other than CDC-LT for sampling An. funestus. While the two most sensitive exposure-free techniques primarily capture host-seeking mosquitoes, both have substantial disadvantages for routine community-based surveillance applications: the CDC-LT requires regular recharging of batteries while the bulkiness of ITT-C makes it difficult to move between sampling locations. RB placed indoors or outdoors and WET had consistently poor sensitivity so it may be useful to evaluate additional alternative methods, such as pyrethrum spray catches and back packer aspirators, for catching resting mosquitoes
- …