19 research outputs found

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio

    Cardiopoietic cell therapy for advanced ischemic heart failure: results at 39 weeks of the prospective, randomized, double blind, sham-controlled CHART-1 clinical trial

    Get PDF
    Cardiopoietic cells, produced through cardiogenic conditioning of patients' mesenchymal stem cells, have shown preliminary efficacy. The Congestive Heart Failure Cardiopoietic Regenerative Therapy (CHART-1) trial aimed to validate cardiopoiesis-based biotherapy in a larger heart failure cohort

    Clinical value of stress transaortic flow rate during dobutamine echocardiography in reduced left ventricular ejection fraction, low-gradient aortic stenosis : a multicenter study

    No full text
    BACKGROUND: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. METHODS: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm2 and mean gradient <40 mmHg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. RESULTS: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94–0.99]; P=0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valve area <1cm2 and aortic valve mean gradient ≥40 mm Hg, or aortic valve mean gradient ≥40 mm Hg, or the novel definition of aortic valve area <1 cm2 at stress FR ≥210 mL/s, only the latter was independently associated with mortality (hazard ratio, 1.72 [95% CI, 1.05–2.82]; P=0.03). Furthermore aortic valve area <1cm2 at stress FR ≥210 mL/s was the only severe aortic stenosis criterion that was associated with improved outcome following aortic valve intervention (P<0.001). Guideline-defined stroke volume flow reserve did not predict mortality. CONCLUSIONS: Stress FR during low-dose dobutamine stress echocardiography was useful for the detection of both AS severity and flow reserve and was associated with improved prediction of outcome following aortic valve intervention

    Effect of the REG1 anticoagulation system versus bivalirudin on outcomes after percutaneous coronary intervention (REGULATE-PCI): a randomised clinical trial.

    No full text
    BACKGROUND REG1 is a novel anticoagulation system consisting of pegnivacogin, an RNA aptamer inhibitor of coagulation factor IXa, and anivamersen, a complementary sequence reversal oligonucleotide. We tested the hypothesis that near complete inhibition of factor IXa with pegnivacogin during percutaneous coronary intervention, followed by partial reversal with anivamersen, would reduce ischaemic events compared with bivalirudin, without increasing bleeding. METHODS We did a randomised, open-label, active-controlled, multicentre, superiority trial to compare REG1 with bivalirudin at 225 hospitals in North America and Europe. We planned to randomly allocate 13,200 patients undergoing percutaneous coronary intervention in a 1:1 ratio to either REG1 (pegnivacogin 1 mg/kg bolus [>99% factor IXa inhibition] followed by 80% reversal with anivamersen after percutaneous coronary intervention) or bivalirudin. Exclusion criteria included ST segment elevation myocardial infarction within 48 h. The primary efficacy endpoint was the composite of all-cause death, myocardial infarction, stroke, and unplanned target lesion revascularisation by day 3 after randomisation. The principal safety endpoint was major bleeding. Analysis was by intention to treat. This trial is registered at ClinicalTrials.gov, identifier NCT01848106. The trial was terminated early after enrolment of 3232 patients due to severe allergic reactions. FINDINGS 1616 patients were allocated REG1 and 1616 were assigned bivalirudin, of whom 1605 and 1601 patients, respectively, received the assigned treatment. Severe allergic reactions were reported in ten (1%) of 1605 patients receiving REG1 versus one (<1%) of 1601 patients treated with bivalirudin. The composite primary endpoint did not differ between groups, with 108 (7%) of 1616 patients assigned REG1 and 103 (6%) of 1616 allocated bivalirudin reporting a primary endpoint event (odds ratio [OR] 1·05, 95% CI 0·80-1·39; p=0·72). Major bleeding was similar between treatment groups (seven [<1%] of 1605 receiving REG1 vs two [<1%] of 1601 treated with bivalirudin; OR 3·49, 95% CI 0·73-16·82; p=0·10), but major or minor bleeding was increased with REG1 (104 [6%] vs 65 [4%]; 1·64, 1·19-2·25; p=0·002). INTERPRETATION The reversible factor IXa inhibitor REG1, as currently formulated, is associated with severe allergic reactions. Although statistical power was limited because of early termination, there was no evidence that REG1 reduced ischaemic events or bleeding compared with bivalirudin. FUNDING Regado Biosciences Inc

    Prolonged antithrombotic therapy in patients after acute coronary syndrome : A critical appraisal of current European Society of Cardiology guidelines

    Get PDF
    The increased risk of non-cardiovascular death in patients receiving clopidogrel or prasugrel in comparison with the placebo group in the Dual Antiplatelet Therapy (DAPT) trial in contrast to the decreased risk of cardiovascular death and all-cause death seen in patients treated with low-dose ticagrelor in the EU label population of the PEGASUS-TIMI 54 trial, resulted in inclusion in the 2020 ESC NSTE-ACS guidelines the recommendation for use of clopidogrel or prasugrel only if the patient is not eligible for treatment with ticagrelor. The prevalence of the primary outcome composed of cardiovascular death, stroke, or myocardial infarction was lower in the low-dose rivaroxaban and acetylsalicylic acid (ASA) group than in the ASA-alone group in the COMPASS trial. Moreover, all-cause mortality and cardiovascular mortality rates were lower in the rivaroxaban-plus-ASA group. Comparison of the PEGASUS-TIMI 54 and COMPASS trial patient characteristics clearly shows that each of these treatment strategies should be addressed at different groups of patients. A greater benefit in post-acute coronary syndrome (ACS) patients with a high risk of ischemic events and without high bleeding risk may be expected with ASA and ticagrelor 60 mg b.i.d. when the therapy is continued without interruption or with short interruption only after ACS. On the other hand, ASA and rivaroxaban 2.5 mg b.i.d. seems to be a better option when indications for dual antithrombotic therapy (DATT) appear after a longer time from ACS (more than 2 years) and/or from cessation of DAPT (more than 1 year) and in patients with multiple vascular bed atherosclerosis. Thus, both options of DATTs complement each other rather than compete, as can be presumed from the recommendations. However, a direct comparison between these strategies should be tested in future clinical trials

    Present criteria for prophylactic ICD implantation:insights from the EU-CERT-ICD (Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators in EUrope) project

    No full text
    Abstract Background: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue. Summary: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (&gt;1500 patients at first ICD implantation, &gt;750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, and first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12‑lead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit. Conclusion: The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular
    corecore