699 research outputs found

    Quantitative sensitivity analysis of surface attached optical fiber strain sensor

    Get PDF
    Optical fiber strain sensors, in particular, the fiber Bragg grating (FBG) type, are widely applied in different applications. The most common installation method is surface-attached. In principle, the optical fiber strain sensor with adequate sampling and signal processing techniques is usually more accurate than electrical resistive strain gauge. However, the strain of the surface of structure may not transfer to the sensing element perfectly. The ratio between the measured and actual strain can be correlated by a strain transfer factor (STF). However, it depends on the material and geometrical properties of the optical fiber and adhesive. It is noneconomical and impractical to measure the STF for every installed sensor. It is desirable to identify the most of the sensitive parameters on the variation of the STF so that the quality control and assurance procedure can be performed more efficiently. In this paper, a quantitative global sensitivity analysis, called extended Fourier amplitude sensitivity test will be performed to compute the first-order and total sensitivity indexes based on a well-established semi-analytical/empirical mechanical model of three material and five geometrical parameters of both integral and optical FBG type optical fiber strain sensor with two different kinds of polymeric coating under three types of strain field in 16 different configurations. From the detail analysis, the most of the sensitive parameters on the STF are bond length, the thickness of adhesive beneath the optical fiber and the deviation of grating position, which are related to workmanship instead of the material properties of the optical fiber and adhesive

    Development of a low cost 3x3 coupler Mach-Zehnder interferometric optical fibre vibration sensor

    Get PDF
    In this paper, a low-cost 3 × 3 coupler Mach–Zehnder interferometric optical fibre vibration sensor is proposed. Unlike the traditional Mach–Zehnder interferometer with a strain free reference arm, two parallel optical fibres with different strain transfer sensitivities are adopted. With the proper demodulation algorithm, the time rate of change in strain can be computed from the light signal of the outputs of a 3 × 3 coupler. The proposed optical fibre vibration sensor is verified by experiment. The vibrating frequency spectrum of a two-layer metal frame is measured by both the proposed optical fibre vibration sensor and micro-electro-mechanical system (MEMS)-based accelerometers. It was found that the proposed vibration sensor is more sensitive compared to the MEMS-based accelerometer, unless it is located near a zero-strain region. Several proposed sensors can easily be multiplexed to minimise the overall cost

    Review: optical fiber sensors for civil engineering applications

    Get PDF
    Optical fiber sensor (OFS) technologies have developed rapidly over the last few decades, and various types of OFS have found practical applications in the field of civil engineering. In this paper, which is resulting from the work of the RILEM technical committee “Optical fiber sensors for civil engineering applications”, different kinds of sensing techniques, including change of light intensity, interferometry, fiber Bragg grating, adsorption measurement and distributed sensing, are briefly reviewed to introduce the basic sensing principles. Then, the applications of OFS in highway structures, building structures, geotechnical structures, pipelines as well as cables monitoring are described, with focus on sensor design, installation technique and sensor performance. It is believed that the State-of-the-Art review is helpful to engineers considering the use of OFS in their projects, and can facilitate the wider application of OFS technologies in construction industry

    Induction of aromatic ring: cleavage dioxygenases in Stenotrophomonas maltophilia strain KB2 in cometabolic systems

    Get PDF
    Stenotrophomonas maltophilia KB2 is known to produce different enzymes of dioxygenase family. The aim of our studies was to determine activity of these enzymes after induction by benzoic acids in cometabolic systems with nitrophenols. We have shown that under cometabolic conditions KB2 strain degraded 0.25–0.4 mM of nitrophenols after 14 days of incubation. Simultaneously degradation of 3 mM of growth substrate during 1–3 days was observed depending on substrate as well as cometabolite used. From cometabolic systems with nitrophenols as cometabolites and 3,4-dihydroxybenzoate as a growth substrate, dioxygenases with the highest activity of protocatechuate 3,4-dioxygenase were isolated. Activity of catechol 1,2- dioxygenase and protocatechuate 4,5-dioxygenase was not observed. Catechol 2,3-dioxygenase was active only in cultures with 4-nitrophenol. Ability of KB2 strain to induce and synthesize various dioxygenases depending on substrate present in medium makes this strain useful in bioremediation of sites contaminated with different aromatic compounds

    Development of Photonic Crystal Fiber Based Gas/ Chemical Sensors

    Full text link
    The development of highly-sensitive and miniaturized sensors that capable of real-time analytes detection is highly desirable. Nowadays, toxic or colorless gas detection, air pollution monitoring, harmful chemical, pressure, strain, humidity, and temperature sensors based on photonic crystal fiber (PCF) are increasing rapidly due to its compact structure, fast response and efficient light controlling capabilities. The propagating light through the PCF can be controlled by varying the structural parameters and core-cladding materials, as a result, evanescent field can be enhanced significantly which is the main component of the PCF based gas/chemical sensors. The aim of this chapter is to (1) describe the principle operation of PCF based gas/ chemical sensors, (2) discuss the important PCF properties for optical sensors, (3) extensively discuss the different types of microstructured optical fiber based gas/ chemical sensors, (4) study the effects of different core-cladding shapes, and fiber background materials on sensing performance, and (5) highlight the main challenges of PCF based gas/ chemical sensors and possible solutions

    Design of Experiments for Screening

    Full text link
    The aim of this paper is to review methods of designing screening experiments, ranging from designs originally developed for physical experiments to those especially tailored to experiments on numerical models. The strengths and weaknesses of the various designs for screening variables in numerical models are discussed. First, classes of factorial designs for experiments to estimate main effects and interactions through a linear statistical model are described, specifically regular and nonregular fractional factorial designs, supersaturated designs and systematic fractional replicate designs. Generic issues of aliasing, bias and cancellation of factorial effects are discussed. Second, group screening experiments are considered including factorial group screening and sequential bifurcation. Third, random sampling plans are discussed including Latin hypercube sampling and sampling plans to estimate elementary effects. Fourth, a variety of modelling methods commonly employed with screening designs are briefly described. Finally, a novel study demonstrates six screening methods on two frequently-used exemplars, and their performances are compared

    Comparison Study of MS-HRM and Pyrosequencing Techniques for Quantification of APC and CDKN2A Gene Methylation

    Get PDF
    There is increasing interest in the development of cost-effective techniques for the quantification of DNA methylation biomarkers. We analyzed 90 samples of surgically resected colorectal cancer tissues for APC and CDKN2A promoter methylation using methylation sensitive-high resolution melting (MS-HRM) and pyrosequencing. MS-HRM is a less expensive technique compared with pyrosequencing but is usually more limited because it gives a range of methylation estimates rather than a single value. Here, we developed a method for deriving single estimates, rather than a range, of methylation using MS-HRM and compared the values obtained in this way with those obtained using the gold standard quantitative method of pyrosequencing. We derived an interpolation curve using standards of known methylated/ unmethylated ratio (0%, 12.5%, 25%, 50%, 75%, and 100% of methylation) to obtain the best estimate of the extent of methylation for each of our samples. We observed similar profiles of methylation and a high correlation coefficient between the two techniques. Overall, our new approach allows MS-HRM to be used as a quantitative assay which provides results which are comparable with those obtained by pyrosequencing

    Auditory-Motor Mapping Training as an Intervention to Facilitate Speech Output in Non-Verbal Children with Autism: A Proof of Concept Study

    Get PDF
    Although up to 25% of children with autism are non-verbal, there are very few interventions that can reliably produce significant improvements in speech output. Recently, a novel intervention called Auditory-Motor Mapping Training (AMMT) has been developed, which aims to promote speech production directly by training the association between sounds and articulatory actions using intonation and bimanual motor activities. AMMT capitalizes on the inherent musical strengths of children with autism, and offers activities that they intrinsically enjoy. It also engages and potentially stimulates a network of brain regions that may be dysfunctional in autism. Here, we report an initial efficacy study to provide ‘proof of concept’ for AMMT. Six non-verbal children with autism participated. Prior to treatment, the children had no intelligible words. They each received 40 individual sessions of AMMT 5 times per week, over an 8-week period. Probe assessments were conducted periodically during baseline, therapy, and follow-up sessions. After therapy, all children showed significant improvements in their ability to articulate words and phrases, with generalization to items that were not practiced during therapy sessions. Because these children had no or minimal vocal output prior to treatment, the acquisition of speech sounds and word approximations through AMMT represents a critical step in expressive language development in children with autism

    Threshold intensity factors as lower boundaries for crack propagation in ceramics

    Get PDF
    BACKGROUND: Slow crack growth can be described in a v (crack velocity) versus K(I )(stress intensity factor) diagram. Slow crack growth in ceramics is attributed to corrosion assisted stress at the crack tip or at any pre-existing defect in the ceramic. The combined effect of high stresses at the crack tip and the presence of water or body fluid molecules (reducing surface energy at the crack tip) induces crack propagation, which eventually may result in fatigue. The presence of a threshold in the stress intensity factor, below which no crack propagation occurs, has been the subject of important research in the last years. The higher this threshold, the higher the reliability of the ceramic, and consequently the longer its lifetime. METHODS: We utilize the Irwin K-field displacement relation to deduce crack tip stress intensity factors from the near crack tip profile. Cracks are initiated by indentation impressions. The threshold stress intensity factor is determined as the time limit of the tip stress intensity when the residual stresses have (nearly) disappeared. RESULTS: We determined the threshold stress intensity factors for most of the all ceramic materials presently important for dental restorations in Europe. Of special significance is the finding that alumina ceramic has a threshold limit nearly identical with that of zirconia. CONCLUSION: The intention of the present paper is to stress the point that the threshold stress intensity factor represents a more intrinsic property for a given ceramic material than the widely used toughness (bend strength or fracture toughness), which refers only to fast crack growth. Considering two ceramics with identical threshold limits, although with different critical stress intensity limits, means that both ceramics have identical starting points for slow crack growth. Fast catastrophic crack growth leading to spontaneous fatigue, however, is different. This growth starts later in those ceramic materials that have larger critical stress intensity factors
    corecore