5,316 research outputs found

    Automated, objective texture segmentation of multibeam echosounder data - Seafloor survey and substrate maps from James Island to Ozette Lake, Washington Outer Coast

    Get PDF
    Without knowledge of basic seafloor characteristics, the ability to address any number of critical marine and/or coastal management issues is diminished. For example, management and conservation of essential fish habitat (EFH), a requirement mandated by federally guided fishery management plans (FMPs), requires among other things a description of habitats for federally managed species. Although the list of attributes important to habitat are numerous, the ability to efficiently and effectively describe many, and especially at the scales required, does not exist with the tools currently available. However, several characteristics of seafloor morphology are readily obtainable at multiple scales and can serve as useful descriptors of habitat. Recent advancements in acoustic technology, such as multibeam echosounding (MBES), can provide remote indication of surficial sediment properties such as texture, hardness, or roughness, and further permit highly detailed renderings of seafloor morphology. With acoustic-based surveys providing a relatively efficient method for data acquisition, there exists a need for efficient and reproducible automated segmentation routines to process the data. Using MBES data collected by the Olympic Coast National Marine Sanctuary (OCNMS), and through a contracted seafloor survey, we expanded on the techniques of Cutter et al. (2003) to describe an objective repeatable process that uses parameterized local Fourier histogram (LFH) texture features to automate segmentation of surficial sediments from acoustic imagery using a maximum likelihood decision rule. Sonar signatures and classification performance were evaluated using video imagery obtained from a towed camera sled. Segmented raster images were converted to polygon features and attributed using a hierarchical deep-water marine benthic classification scheme (Greene et al. 1999) for use in a geographical information system (GIS). (PDF contains 41 pages.

    Transient neurological symptoms in the older population:report of a prospective cohort study--the Medical Research Council Cognitive Function and Ageing Study (CFAS)

    Get PDF
    Transient ischaemic attack (TIA) is a recognised risk factor for stroke in the older population requiring timely assessment and treatment by a specialist. The need for such TIA services is driven by the epidemiology of transient neurological symptoms, which may not be caused by TIA. We report prevalence and incidence of transient neurological symptoms in a large UK cohort study of older people

    Clinical Diagnosis of Placenta Accreta and Clinicopathological Outcomes

    Get PDF
    Objective To investigate the association between the intraoperative diagnosis of placenta accreta at the time of cesarean hysterectomy and pathological diagnosis. Study Design This is a retrospective cohort study of all patients undergoing cesarean hysterectomy for suspected placenta accreta from 2000 to 2016 at Barnes-Jewish Hospital. The primary outcome was the presence of invasive placentation on the pathology report. We estimated predictive characteristics of clinical diagnosis of placenta accreta using pathological diagnosis as the correct diagnosis. Results There were 50 cesarean hysterectomies performed for suspected abnormal placentation from 2000 to 2016. Of these, 34 (68%) had a diagnosis of accreta preoperatively and 16 (32%) were diagnosed intraoperatively at the time of cesarean delivery. Two patients had no pathological evidence of invasion, corresponding to a false-positive rate of 4% (95% confidence interval [CI]: 0.5%, 13.8%) and a positive predictive value of 96% (95% CI: 86.3%, 99.5%). There were no differences in complications among patients diagnosed intraoperatively compared with those diagnosed preoperatively. Conclusion Most patients undergoing cesarean hysterectomy for placenta accreta do have this diagnosis confirmed on pathology. However, since the diagnosis of placenta accreta was made intraoperatively in nearly a third of cesarean hysterectomies, intraoperative vigilance is required as the need for cesarean hysterectomy may not be anticipated preoperatively

    Handcrafting Attachment: A User-Centered Approach

    Get PDF
    Management, above all, is the controlling element responsible for coordinating the three basic business functions; production, marketing, and finance. Mechanisms exist to facilitate the finance function with influence coming from outside regulatory bodies such as the AICPA, IIA, SEC, and other regulators. Integrating the finance function into organizations, then, becomes somewhat generic (although some would argue this point). Coordinating the functions of marketing and production is a much more difficult endeavor because it lacks the standardization seen in finance. This paper suggests employing a more user-focused approach as a means to improving the overall quality of products, and eventually, the success of the organization. Specifically, this paper explores the role of the human brain in the calculus of choice, discusses the role of consumer involvement as it leads to product attachment, and offers suggestions for employing contextual research to improve product design and quality

    Effects of Cardiac Structural Remodelling During Heart Failure on Cardiac Excitation – Insights from a Heterogeneous 3D Model of the Rabbit Atria

    Get PDF
    Heart failure is a leading cause of morbidity and mortality in the western world. One of the effects of heart failure is the structural remodelling of cardiac tissue, including tissue dilation and development of fibrosis. It is therefore important to study these changes and their effect on cardiac activity, in order to gain a better understanding of the underlying mechanisms in arrhythmogenesis, which will hopefully enable us to develop better treatments for heart failure. In this study we developed biophysically detailed models of the rabbit atria for normal and heart failure conditions. These models were used to study the effects of structural remodelling of heart failure on cardiac excitation wave conduction. Anatomical reconstructions of the control and heart failure hearts were based on contrast enhanced micro-CT imaging. Fibre orientation was extracted from the control and heart failure datasets. Effects of heart failure geometry on the activation pattern of atrial excitation waves were analyzed. It was found that atrial activation time increased from the control to the heart failure case in both isotropic and anisotropic conditions, which is attributed primarily to the dilation of tissue caused by heart failure

    Towards photostatistics from photon-number discriminating detectors

    Get PDF
    We study the properties of a photodetector that has a number-resolving capability. In the absence of dark counts, due to its finite quantum efficiency, photodetection with such a detector can only eliminate the possibility that the incident field corresponds to a number of photons less than the detected photon number. We show that such a {\em non-photon} number-discriminating detector, however, provides a useful tool in the reconstruction of the photon number distribution of the incident field even in the presence of dark counts.Comment: 7 pages, 4 figure

    NASA's Evolutionary Xenon Thruster (NEXT) Prototype Model 1R (PM1R) Ion Thruster and Propellant Management System Wear Test Results

    Get PDF
    The results of the NEXT wear test are presented. This test was conducted with a 36-cm ion engine (designated PM1R) and an engineering model propellant management system. The thruster operated with beam extraction for a total of 1680 hr and processed 30.5 kg of xenon during the wear test, which included performance testing and some operation with an engineering model power processing unit. A total of 1312 hr was accumulated at full power, 277 hr at low power, and the remainder was at intermediate throttle levels. Overall ion engine performance, which includes thrust, thruster input power, specific impulse, and thrust efficiency, was steady with no indications of performance degradation. The propellant management system performed without incident during the wear test. The ion engine and propellant management system were also inspected following the test with no indication of anomalous hardware degradation from operation
    corecore