41 research outputs found

    C2 prosthesis: anterior upper cervical fixation device to reconstruct the second cervical vertebra

    Get PDF
    Destruction of the second cervical vertebra leads to a highly unstable situation. Reconstruction is difficult because the axis plays a central role in rotatory movements and has a unique function in redistributing axial loads. The axis transfers the axial load of the two lateral masses of the atlas to three surfaces on the third cervical vertebra: the two articular facets and the vertebral body. As reconstruction is difficult and the instability in this region is life threatening, pathological processes are often treated less radically compared to other areas of the cervical spine. However, this more moderate approach may result in worse outcomes and prognoses. This paper presents the development of a new implant (C2 prosthesis) and two illustrative cases describing the implementation of this new implant. The C2 prosthesis provides anterior support and therefore allows a more radical surgical approach

    Higher fibrinogen concentrations for reduction of transfusion requirements during major paediatric surgery: A prospective randomised controlled trial†

    Get PDF
    Background Hypofibrinogenaemia is one of the main reasons for development of perioperative coagulopathy during major paediatric surgery. The aim of this study was to assess whether prophylactic maintenance of higher fibrinogen concentrations through administration of fibrinogen concentrate would decrease the volume of transfused red blood cell (RBCs). Methods In this prospective, randomised, clinical trial, patients aged 6 months to 17 yr undergoing craniosynostosis and scoliosis surgery received fibrinogen concentrate (30 mg kg−1) at two predefined intraoperative fibrinogen concentrations [ROTEM¼ FIBTEM maximum clot firmness (MCF) of <8 mm (conventional) or <13 mm (early substitution)]. Total volume of transfused RBCs was recorded over 24 h after start of surgery. Results Thirty children who underwent craniosynostosis surgery and 19 children who underwent scoliosis surgery were treated per protocol. During craniosynostosis surgery, children in the early substitution group received significantly less RBCs (median, 28 ml kg−1; IQR, 21 to 50 ml kg−1) compared with the conventional fibrinogen trigger of <8 mm (median, 56 ml kg−1; IQR, 28 to 62 ml kg−1) (P=0.03). Calculated blood loss as per cent of estimated total blood volume decreased from a median of 160% (IQR, 110-190%) to a median of 90% (IQR, 78-110%) (P=0.017). No significant changes were observed in the scoliosis surgery population. No bleeding events requiring surgical intervention, postoperative transfusions of RBCs, or treatment-related adverse events were observed. Conclusions Intraoperative administration of fibrinogen concentrate using a FIBTEM MCF trigger level of <13 mm can be successfully used to significantly decrease bleeding, and transfusion requirements in the setting of craniosynostosis surgery, but not scoliosis. Clinical trial registry number ClinicalTrials.gov NCT0148783

    Spacecraft potential control for Double Star

    No full text
    International audienceThe spacecraft potential of Double Star TC-1 is positive in large parts of the orbits due to the photo-effect from solar EUV irradiation. These positive potentials typically disturb low energy plasma measurements on board. The potential can be reduced, and thereby the particle measurements improved, by emitting a positive ion beam. This method has successfully been applied on several other spacecraft and it has also been chosen for TC-1. The instrument TC-1/ASPOC is a derivative of the Cluster/ASPOC instruments, from which it has inherited many features. The paper describes the adaptations and further developments made for the ion emitters and the electronics. The instrument performs very well and can support higher beam currents than on Cluster. The expected significant improvement of the low energy particle measurements on board was indeed observed. The modifications of the electron distributions are analysed for a one-time interval when the spacecraft was located in the magnetosheath. The change in the potential due to the ion beam was determined, and first studies of the 3-D electron distributions in response to the spacecraft potential control have been performed, which indicate that the method works as expected

    The design of the instrument control unit and its role within the data processing system of the ESA PLATO Mission

    Get PDF
    PLATO1 is an M-class mission of the European Space Agency's Cosmic Vision program, whose launch is foreseen by 2026. PLAnetary Transits and Oscillations of stars aims to characterize exoplanets and exoplanetary systems by detecting planetary transits and conducting asteroseismology of their parent stars. PLATO is the next generation planetary transit space experiment, as it will fly after CoRoT, Kepler, TESS and CHEOPS; its objective is to characterize exoplanets and their host stars in the solar neighbors. While it is built on the heritage from previous missions, the major breakthrough to be achieved by PLATO will come from its strong focus on bright targets, typically with mvv<=8. The prime science goals characterizing and distinguishing PLATO from the previous missions are: the detection and characterization of exoplanetary systems of all kinds, including both the planets and their host stars, reaching down to small, terrestrial planets in the habitable zone; the identification of suitable targets for future, more detailed characterization, including a spectroscopic search for biomarkers in nearby habitable exoplanets (e.g. ARIEL Mission scientific case, E-ELT observations from Ground); a full characterization of the planet host stars, via asteroseismic analysis: this will provide the Community with the masses, radii and ages of the host stars, from which masses, radii and ages of the detected planets will be determined

    The Soft X-ray Imager (SXI) on the SMILE Mission

    Get PDF
    The Soft X-ray Imager (SXI) is part of the scientific payload of the Solar wind Magnetosphere Ionosphere Link Explorer (SMILE) mission. SMILE is a joint science mission between the European Space Agency (ESA) and the Chinese Academy of Sciences (CAS) and is due for launch in 2025. SXI is a compact X-ray telescope with a wide field-of-view (FOV) capable of encompassing large portions of Earth’s magnetosphere from the vantage point of the SMILE orbit. SXI is sensitive to the soft X-rays produced by the Solar Wind Charge eXchange (SWCX) process produced when heavy ions of solar wind origin interact with neutral particles in Earth’s exosphere. SWCX provides a mechanism for boundary detection within the magnetosphere, such as the position of Earth’s magnetopause, because the solar wind heavy ions have a very low density in regions of closed magnetic field lines. The sensitivity of the SXI is such that it can potentially track movements of the magnetopause on timescales of a few minutes and the orbit of SMILE will enable such movements to be tracked for segments lasting many hours. SXI is led by the University of Leicester in the United Kingdom (UK) with collaborating organisations on hardware, software and science support within the UK, Europe, China and the United States

    The Comet Interceptor Mission

    Get PDF
    Here we describe the novel, multi-point Comet Interceptor mission. It is dedicated to the exploration of a little-processed long-period comet, possibly entering the inner Solar System for the first time, or to encounter an interstellar object originating at another star. The objectives of the mission are to address the following questions: What are the surface composition, shape, morphology, and structure of the target object? What is the composition of the gas and dust in the coma, its connection to the nucleus, and the nature of its interaction with the solar wind? The mission was proposed to the European Space Agency in 2018, and formally adopted by the agency in June 2022, for launch in 2029 together with the Ariel mission. Comet Interceptor will take advantage of the opportunity presented by ESA’s F-Class call for fast, flexible, low-cost missions to which it was proposed. The call required a launch to a halo orbit around the Sun-Earth L2 point. The mission can take advantage of this placement to wait for the discovery of a suitable comet reachable with its minimum ΔV capability of 600 ms−1. Comet Interceptor will be unique in encountering and studying, at a nominal closest approach distance of 1000 km, a comet that represents a near-pristine sample of material from the formation of the Solar System. It will also add a capability that no previous cometary mission has had, which is to deploy two sub-probes – B1, provided by the Japanese space agency, JAXA, and B2 – that will follow different trajectories through the coma. While the main probe passes at a nominal 1000 km distance, probes B1 and B2 will follow different chords through the coma at distances of 850 km and 400 km, respectively. The result will be unique, simultaneous, spatially resolved information of the 3-dimensional properties of the target comet and its interaction with the space environment. We present the mission’s science background leading to these objectives, as well as an overview of the scientific instruments, mission design, and schedule

    Lumbosacral fracture dislocation in a lumberjack

    No full text
    corecore