9 research outputs found

    Les étiages 2011 et 2012 en Cévennes et leurs conséquences sur le plan de la qualité des eaux et le développement des algues

    No full text
    Ce rapport fait la synthÚse des données hydrologiques recueillies par l'antenne cévenole de l'UMR ESPACE 7300 dans le secteur de Peyrolles (Gardon de Saint Jean et Vallée obscure) au cours des deux cycles hydrologiques 2010-2011 et 2011-2012

    Improving vision for surgeons during laparoscopy: the Enhanced Laparoscopic Vision System ELViS

    No full text
    12 mois d'embargo sur la version "Author Accepted Manuscript" (celle déposée ici)International audienceBackground: For many abdominal surgical interventions, laparotomy has gradually been replaced by laparoscopy, with numerous benefits for the patient in terms of post-operative recovery. However, during laparoscopy, the endoscope only provides a single viewpoint to the surgeon, leaving numerous blind-spots and opening the way to peri-operative adverse events. Alternative camera systems have been proposed, but many lack the requisite resolution/robustness for use during surgery or cannot provide real-time images. Here, we present the added value of the Enhanced Laparoscopic Vision System (ELViS) which overcomes these limitations and provides a broad view of the surgical field in addition to the usual high-resolution endoscope. Methods: Experienced laparoscopy surgeons performed several typical procedure steps on a live pig model. The time-to-completion for surgical exercises performed by conventional endoscopy and ELViSassisted surgery was measured. A debriefing interview following each operating session was conducted by an ergonomist, and a System Usability Scale (SUS) score was determined. Results: Proof of concept of ELVIS was achieved in an animal model with 7 expert surgeons without peroperative adverse events related to the surgical device. No differences were found in time-tocompletion. Mean SUS score was 74.7, classifying the usability of the ELViS as "good". During the debriefing interview, surgeons highlighted several situations where the ELViS provided a real advantage (such as during instrument insertion, exploration of the abdominal cavity or for orientation during close work), and also suggested avenues for improvement of the system. Conclusions: This first test of the ELViS prototype on a live animal model demonstrated its usability and provided promising and useful feedback for further development

    Accuracy of elastic fusion biopsy in daily practice: Results of a multicenter study of 2115 patients

    No full text
    International audienceOBJECTIVES:To assess the accuracy of Koelis fusion biopsy for the detection of prostate cancer and clinically significant prostate cancer in the everyday practice.METHODS:We retrospectively enrolled 2115 patients from 15 institutions in four European countries undergoing transrectal Koelis fusion biopsy from 2010 to 2017. A variable number of target (usually 2-4) and random cores (usually 10-14) were carried out, depending on the clinical case and institution habits. The overall and clinically significant prostate cancer detection rates were assessed, evaluating the diagnostic role of additional random biopsies. The cancer detection rate was correlated to multiparametric magnetic resonance imaging features and clinical variables.RESULTS:The mean number of targeted and random cores taken were 3.9 (standard deviation 2.1) and 10.5 (standard deviation 5.0), respectively. The cancer detection rate of Koelis biopsies was 58% for all cancers and 43% for clinically significant prostate cancer. The performance of additional, random cores improved the cancer detection rate of 13% for all cancers (P < 0.001) and 9% for clinically significant prostate cancer (P < 0.001). Prostate cancer was detected in 31%, 66% and 89% of patients with lesions scored as Prostate Imaging Reporting and Data System 3, 4 and 5, respectively. Clinical stage and Prostate Imaging Reporting and Data System score were predictors of prostate cancer detection in multivariate analyses. Prostate-specific antigen was associated with prostate cancer detection only for clinically significant prostate cancer.CONCLUSIONS:Koelis fusion biopsy offers a good cancer detection rate, which is increased in patients with a high Prostate Imaging Reporting and Data System score and clinical stage. The performance of additional, random cores seems unavoidable for correct sampling. In our experience, the Prostate Imaging Reporting and Data System score and clinical stage are predictors of prostate cancer and clinically significant prostate cancer detection; prostate-specific antigen is associated only with clinically significant prostate cancer detection, and a higher number of biopsy cores are not associated with a higher cancer detection rate

    Performance of a Region of Interest–based Algorithm in Diagnosing International Society of Urological Pathology Grade Group ≄2 Prostate Cancer on the MRI-FIRST Database—CAD-FIRST Study

    No full text
    International audienceBackground and objective: Prostate multiparametric magnetic resonance imaging (MRI) shows high sensitivity for International Society of Urological Pathology grade group (GG) ≄2 cancers. Many artificial intelligence algorithms have shown promising results in diagnosing clinically significant prostate cancer on MRI. To assess a region-of-interest-based machine-learning algorithm aimed at characterising GG ≄2 prostate cancer on multiparametric MRI.Methods: The lesions targeted at biopsy in the MRI-FIRST dataset were retrospectively delineated and assessed using a previously developed algorithm. The Prostate Imaging-Reporting and Data System version 2 (PI-RADSv2) score assigned prospectively before biopsy and the algorithm score calculated retrospectively in the regions of interest were compared for diagnosing GG ≄2 cancer, using the areas under the curve (AUCs), and sensitivities and specificities calculated with predefined thresholds (PIRADSv2 scores ≄3 and ≄4; algorithm scores yielding 90% sensitivity in the training database). Ten predefined biopsy strategies were assessed retrospectively.Key findings and limitations: After excluding 19 patients, we analysed 232 patients imaged on 16 different scanners; 85 had GG ≄2 cancer at biopsy. At patient level, AUCs of the algorithm and PI-RADSv2 were 77% (95% confidence interval [CI]: 70-82) and 80% (CI: 74-85; p = 0.36), respectively. The algorithm's sensitivity and specificity were 86% (CI: 76-93) and 65% (CI: 54-73), respectively. PI-RADSv2 sensitivities and specificities were 95% (CI: 89-100) and 38% (CI: 26-47), and 89% (CI: 79-96) and 47% (CI: 35-57) for thresholds of ≄3 and ≄4, respectively. Using the PI-RADSv2 score to trigger a biopsy would have avoided 26-34% of biopsies while missing 5-11% of GG ≄2 cancers. Combining prostate-specific antigen density, the PI-RADSv2 and algorithm's scores would have avoided 44-47% of biopsies while missing 6-9% of GG ≄2 cancers. Limitations include the retrospective nature of the study and a lack of PI-RADS version 2.1 assessment.Conclusions and clinical implications: The algorithm provided robust results in the multicentre multiscanner MRI-FIRST database and could help select patients for biopsy.Patient summary: An artificial intelligence-based algorithm aimed at diagnosing aggressive cancers on prostate magnetic resonance imaging showed results similar to expert human assessment in a prospectively acquired multicentre test database

    Use of prostate systematic and targeted biopsy on the basis of multiparametric MRI in biopsy-naive patients (MRI-FIRST): a prospective, multicentre, paired diagnostic study

    No full text
    International audienceBACKGROUND:Whether multiparametric MRI improves the detection of clinically significant prostate cancer and avoids the need for systematic biopsy in biopsy-naive patients remains controversial. We aimed to investigate whether using this approach before biopsy would improve detection of clinically significant prostate cancer in biopsy-naive patients.METHODS:In this prospective, multicentre, paired diagnostic study, done at 16 centres in France, we enrolled patients aged 18-75 years with prostate-specific antigen concentrations of 20 ng/mL or less, and with stage T2c or lower prostate cancer. Eligible patients had been referred for prostate multiparametric MRI before a first set of prostate biopsies, with a planned interval of less than 3 months between MRI and biopsies. An operator masked to multiparametric MRI results did a systematic biopsy by obtaining 12 systematic cores and up to two cores targeting hypoechoic lesions. In the same patient, another operator targeted up to two lesions seen on MRI with a Likert score of 3 or higher (three cores per lesion) using targeted biopsy based on multiparametric MRI findings. Patients with negative multiparametric MRI (Likert score ≀2) had systematic biopsy only. The primary outcome was the detection of clinically significant prostate cancer of International Society of Urological Pathology grade group 2 or higher (csPCa-A), analysed in all patients who received both systematic and targeted biopsies and whose results from both were available for pathological central review, including patients who had protocol deviations. This study is registered with ClinicalTrials.gov, number NCT02485379, and is closed to new participants.FINDINGS:Between July 15, 2015, and Aug 11, 2016, we enrolled 275 patients. 24 (9%) were excluded from the analysis. 53 (21%) of 251 analysed patients had negative (Likert ≀2) multiparametric MRI. csPCa-A was detected in 94 (37%) of 251 patients. 13 (14%) of these 94 patients were diagnosed by systematic biopsy only, 19 (20%) by targeted biopsy only, and 62 (66%) by both techniques. Detection of csPCa-A by systematic biopsy (29·9%, 95% CI 24·3-36·0) and targeted biopsy (32·3%, 26·5-38·4) did not differ significantly (p=0·38). csPCa-A would have been missed in 5·2% (95% CI 2·8-8·7) of patients had systematic biopsy not been done, and in 7·6% (4·6-11·6) of patients had targeted biopsy not been done. Four grade 3 post-biopsy adverse events were reported (3 cases of prostatitis, and 1 case of urinary retention with haematuria).INTERPRETATION:There was no difference between systematic biopsy and targeted biopsy in the detection of ISUP grade group 2 or higher prostate cancer; however, this detection was improved by combining both techniques and both techniques showed substantial added value. Thus, obtaining a multiparametric MRI before biopsy in biopsy-naive patients can improve the detection of clinically significant prostate cancer but does not seem to avoid the need for systematic biopsy

    Stopping or maintaining oral anticoagulation in patients undergoing photoselective vaporization of the prostate (SOAP) surgery for benign prostate obstruction: study protocol for a multicentre randomized controlled trial

    Get PDF
    International audienceBACKGROUND:Lower urinary tract symptoms related to benign prostatic obstruction (BPO) are frequent in men aged > 50 years. Based on the use of innovative medical devices, a number of transurethral ablative techniques have recently been developed for the surgical treatment of BPO. In recent years, GreenLight photoselective vaporization of the prostate (PVP) has been considered as a non-inferior alternative to transurethral resection of the prostate. The GreenLight PVP is usually considered as an interesting surgical option for patients treated via oral anticoagulants (OACs) with regard to its haemostatic properties. The aim of this study was to assess the impact of maintaining OAC treatment in patients undergoing PVP.METHODS:This study is a multicentre, open-label, randomized controlled trial (RCT) designed to show the non-inferiority of PVP surgery in patients with BPO treated with OACs. This study is designed to enrol 386 OAC-treated patients (treated with vitamin K antagonists and direct oral anticoagulants) who are undergoing PVP for BPO. Patients will be randomized (1:1) to either maintain or stop OAC treatment during the perioperative course. The intervention group will maintain OAC treatment until the day before surgery and resume OAC treatment the day after surgery, whereas the control group will stop OAC treatment (with or without low-molecular-weight heparin bridging therapy) according to the anaesthesia guidelines. The primary outcome of interest to be assessed is the 30-day complications rate according to the Clavien-Dindo classification. The secondary endpoint will examine the 30-day rate of haemorrhagic and thrombotic events. This study will provide 80% power to show non-inferiority, defined as not worse than a 10% (non-inferiority margin) inferior change in the proportion of patients with good outcomes (Clavien-Dindo score < 2), using two-tailed 95% confidence intervals.DISCUSSION:This first multicentre RCT in the field is underway to evaluate the safety and efficacy of PVP in patients with ongoing OAC therapy. The study results could influence the perioperative management of OACs in BPO surgery with a high level of evidence
    corecore