603 research outputs found

    High-temperature Hydrogen Chloride Releases from Mixtures of Sodium Chloride with Sulfates: Implications for the Chlorine-Mineralogy as Determined by the Sample Analysis at Mars Instrument on the Curiosity Rover in Gale Crater, Mars

    Get PDF
    Hydrogen chloride releases above 500 C occurred in several samples analyzed by the Sample Analysis at Mars (SAM) evolved gas analyzer on the Curiosity rover in Gale crater. These have been attributed to reactions between chlorides (original or from oxychlorine decomposition) and water. Some of these HCl releases that peaked below the melting temperature of common chlorides did not co-evolve with oxygen or water, and were not explained by laboratory analog work (Figure 1). Therefore, these HCl releases were not caused by MgCl2 or soley due to reactions between water and melting chlorides. The goal of this work was to explain the HCl releases that did not co-evolve with oxygen or water and occurred below the melting point of common chlorides, which have not been explained by previous laboratory analog work. This work specifically evaluates the role of evolved SO2 in the production of HCl

    High Magnetic Field NMR Studies of LiVGe2_2O6_6, a quasi 1-D Spin S=1S = 1 System

    Full text link
    We report 7^{7}Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe2_2O6_6, whose AF transition temperature is TN24.5T_{\text{N}}\simeq 24.5 K. The field (B0B_0) and temperature (TT) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate (T11T_1^{-1}), and the spin-phase relaxation rate (T21T_2^{-1}), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the TT-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the spectra and the T11T_1^{-1} data show that B0B_0 has at most a small effect on the alignment of the AF moment. There is no spin-flop transition up to 44.5 T. These features indicate a very large magnetic anisotropy energy in LiVGe2_2O6_6 with orbital degrees of freedom playing an important role. Below 8 K, T11T_1^{-1} varies substantially with the orientation of B0B_0 in the plane perpendicular to the c-axis, suggesting a small energy gap for magnetic fluctuations that is very anisotropic.Comment: submitted to Phys. Rev.

    Quasi-long-range order in the random anisotropy Heisenberg model: functional renormalization group in 4-\epsilon dimensions

    Full text link
    The large distance behaviors of the random field and random anisotropy O(N) models are studied with the functional renormalization group in 4-\epsilon dimensions. The random anisotropy Heisenberg (N=3) model is found to have a phase with the infinite correlation radius at low temperatures and weak disorder. The correlation function of the magnetization obeys a power law < m(x) m(y) >\sim |x-y|^{-0.62\epsilon}. The magnetic susceptibility diverges at low fields as \chi \sim H^{-1+0.15\epsilon}. In the random field O(N) model the correlation radius is found to be finite at the arbitrarily weak disorder for any N>3. The random field case is studied with a new simple method, based on a rigorous inequality. This approach allows one to avoid the integration of the functional renormalization group equations.Comment: 12 pages, RevTeX; a minor change in the list of reference

    Embedded pitch adapters: a high-yield interconnection solution for strip sensors

    Get PDF
    A proposal to fabricate large area strip sensors with integrated, or embedded, pitch adapters is presented for the End-cap part of the Inner Tracker in the ATLAS experiment. To implement the embedded pitch adapters, a second metal layer is used in the sensor fabrication, for signal routing to the ASICs. Sensors with different embedded pitch adapters have been fabricated in order to optimize the design and technology. Inter-strip capacitance, noise, pick-up, cross-talk, signal efficiency, and fabrication yield have been taken into account in their design and fabrication. Inter-strip capacitance tests taking into account all channel neighbors reveal the important differences between the various designs considered. These tests have been correlated with noise figures obtained in full assembled modules, showing that the tests performed on the bare sensors are a valid tool to estimate the final noise in the full module. The full modules have been subjected to test beam experiments in order to evaluate the incidence of cross-talk, pick-up, and signal loss. The detailed analysis shows no indication of cross-talk or pick-up as no additional hits can be observed in any channel not being hit by the beam above 170 mV threshold, and the signal in those channels is always below 1% of the signal recorded in the channel being hit, above 100 mV threshold. First results on irradiated mini-sensors with embedded pitch adapters do not show any change in the interstrip capacitance measurements with only the first neighbors connected

    Study of surface properties of ATLAS12 strip sensors and their radiation resistance

    Get PDF
    A radiation hard nþ-in-p micro-strip sensor for the use in the Upgrade of the strip tracker of the ATLAS experiment at the High Luminosity Large Hadron Collider (HL-LHC) has been developed by the “ATLAS ITk Strip Sensor collaboration” and produced by Hamamatsu Photonics. Surface properties of different types of end-cap and barrel miniature sensors of the latest sensor design ATLAS12 have been studied before and after irradiation. The tested barrel sensors vary in “punchthrough protection” (PTP) structure, and the end-cap sensors, whose stereo-strips differ in fan geometry, in strip pitch and in edge strip ganging options. Sensors have been irradiated with proton fluences of up to 1 1016 neq/cm2 , by reactor neutron fluence of 1 1015 neq/cm2 and by gamma rays from 60Co up to dose of 1 MGy. The main goal of the present study is to characterize the leakage current for microdischarge breakdown voltage estimation, the inter-strip resistance and capacitance, the bias resistance and the effectiveness of PTP structures as a function of bias voltage and fluence. It has been verified that the ATLAS12 sensors have high breakdown voltage well above the operational voltage which implies that different geometries of sensors do not influence their stability. The inter-strip isolation is a strong function of irradiation fluence, however the sensor performance is acceptable in the expected range for HL-LHC. New gated PTP structure exhibits low PTP onset voltage and sharp cut-off of effective resistance even at the highest tested radiation fluence. The inter-strip capacitance complies with the technical specification required before irradiation and no radiation-induced degradation was observed. A summary of ATLAS12 sensors tests is presented including a comparison of results from different irradiation sites. The measured characteristics are compared with the previous prototype of the sensor design, ATLAS07

    Charge collection and field profile studies of heavily irradiated strip sensors for the ATLAS inner tracker upgrade

    Get PDF
    The ATLAS group has evaluated the charge collection in silicon microstrip sensors irradiated up to a fluence of 1×1016 neq/cm2, exceeding the maximum of 1.6×1015 neq/cm2 expected for the strip tracker during the high luminosity LHC (HL-LHC) period including a safety factor of 2. The ATLAS12, n+-on-p type sensor, which is fabricated by Hamamatsu Photonics (HPK) on float zone (FZ) substrates, is the latest barrel sensor prototype. The charge collection from the irradiated 1×1 cm2 barrel test sensors has been evaluated systematically using penetrating β-rays and an Alibava readout system. The data obtained at different measurement sites are compared with each other and with the results obtained from the previous ATLAS07 design. The results are very consistent, in particular, when the deposit charge is normalized by the sensor's active thickness derived from the edge transient current technique (edge-TCT) measurements. The measurements obtained using β-rays are verified to be consistent with the measurements using an electron beam. The edge-TCT is also effective for evaluating the field profiles across the depth. The differences between the irradiated ATLAS07 and ATLAS12 samples have been examined along with the differences among the samples irradiated with different radiation sources: neutrons, protons, and pions. The studies of the bulk properties of the devices show that the devices can yield a sufficiently large signal for the expected fluence range in the HL-LHC, thereby acting as precision tracking sensors

    America's Rural Hospitals: A Selective Review of 1980s Research

    Full text link
    We review 1980s research on American rural hospitals within the context of a decade of increasing restrictiveness in the reimbursement and operating environments. Areas addressed include rural hospital definitions, organizational and financial performance, and strategic management activities. The latter category consists of hospital closure, diversification and vertical integration, swing-bed conversion, sole community provider designation, horizontal integration and multihospital system affiliation, marketing, and patient retention. The review suggests several research needs, including: developing more meaningful definitions of rural hospitals, engaging in methodologically sound work on the effects of innovative programs and strategic management activities—including conversion of the facility itself—on rural hospital performance, and completing studies of the effects of rural hospital closure or conversion on the health of the communities served.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/74857/1/j.1748-0361.1990.tb00682.x.pd

    Evaluation of the performance of irradiated silicon strip sensors for the forward detector of the ATLAS Inner Tracker Upgrade

    Get PDF
    The upgrade to the High-Luminosity LHC foreseen in about ten years represents a great challenge for the ATLAS inner tracker and the silicon strip sensors in the forward region. Several strip sensor designs were developed by the ATLAS collaboration and fabricated by Hamamatsu in order to maintain enough performance in terms of charge collection efficiency and its uniformity throughout the active region. Of particular attention, in the case of a stereo-strip sensor, is the area near the sensor edge where shorter strips were ganged to the complete ones. In this work the electrical and charge collection test results on irradiated miniature sensors with forward geometry are presented. Results from charge collection efficiency measurements show that at the maximum expected fluence, the collected charge is roughly halved with respect to the one obtained prior to irradiation. Laser measurements show a good signal uniformity over the sensor. Ganged strips have a similar efficiency as standard strips
    corecore