138 research outputs found

    Lifting the veil of secrecy: maternal and neonatal outcome of oocyte donation pregnancies in Germany

    Get PDF
    Background: In Germany, performing fertility procedures involving oocyte donation is illegal, as stated by the Embryo Protection Law. Nonetheless, in our clinical routine we attend to a steadily rising number of pregnant women, who have sought oocyte donation abroad. Due to the legal circumstances many women opt to keep the origin of their pregnancy a secret. However, studies have shown, that oocyte donation is an independent risk factor for the development of pregnancy complications, such as preeclampsia. Objective: The aim of this study is to evaluate maternal and neonatal outcomes of oocyte donation pregnancies in three large obstetric care units in Berlin, Germany. Methods: We retrospectively analyzed all available medical data on oocyte donation pregnancies at Charite University hospital, Vivantes Hospital Friedrichshain, and Neukoelln in the German capital. Results: We included 115 oocyte donation (OD) pregnancies in the present study. Our data are based on 62 singleton, 44 twin, 7 triplet, and 2 quadruplet oocyte donation pregnancies. According to our data, oocyte donation pregnancies are associated with a high risk of adverse maternal and fetal outcome, i.e., hypertension in pregnancy, preterm delivery, Cesarean section as mode of delivery, and increased peripartum hemorrhage. Conclusion: Although oocyte donation is prohibited by German law, many couples go abroad to seek reproductive measures using oocyte donation after former treatment options have failed. OD pregnancies are associated with a high risk of preeclampsia, C-section as mode of delivery, and peripartum hemorrhage. Detailed knowledge of the associated risks is of utmost importance to both the patient and the treating physician and midwife

    Impossible protest: noborders in Calais

    Get PDF
    Since the closure of the Red Cross refugee reception centre in Sangatte, undocumented migrants in Calais hoping to cross the border to Britain have been forced to take refuge in a number of squatted migrant camps, locally known by all as ‘the jungles.’ Unauthorised shanty-like residences built by the migrants themselves, living conditions in the camps are very poor. In June 2009, European ‘noborder’ activists set up a week-long protest camp in the area with the intention of confronting the authorities over their treatment of undocumented migrants. In this article, we analyse the June 2009 noborder camp as an instance of ‘immigrant protest.’ Drawing on ethnographic materials and Jacques Rancière's work on politics and aesthetics, we construct a typology of forms of border control through which to analyse the different ways in which the politics of the noborder camp were staged, performed and policed. Developing a critique of policing practices which threatened to make immigrant protest ‘impossible’, we highlight moments of protest which, through the affirmation of an ‘axiomatic’ equality, disrupted and disarticulated the borders between citizens and non-citizens, the political and non-political

    Lifting the veil of secrecy: maternal and neonatal outcome of oocyte donation pregnancies in Germany

    Get PDF
    BACKGROUND: In Germany, performing fertility procedures involving oocyte donation is illegal, as stated by the Embryo Protection Law. Nonetheless, in our clinical routine we attend to a steadily rising number of pregnant women, who have sought oocyte donation abroad. Due to the legal circumstances many women opt to keep the origin of their pregnancy a secret. However, studies have shown, that oocyte donation is an independent risk factor for the development of pregnancy complications, such as preeclampsia. OBJECTIVE: The aim of this study is to evaluate maternal and neonatal outcomes of oocyte donation pregnancies in three large obstetric care units in Berlin, Germany. METHODS: We retrospectively analyzed all available medical data on oocyte donation pregnancies at Charité University hospital, Vivantes Hospital Friedrichshain, and Neukoelln in the German capital. RESULTS: We included 115 oocyte donation (OD) pregnancies in the present study. Our data are based on 62 singleton, 44 twin, 7 triplet, and 2 quadruplet oocyte donation pregnancies. According to our data, oocyte donation pregnancies are associated with a high risk of adverse maternal and fetal outcome, i.e., hypertension in pregnancy, preterm delivery, Cesarean section as mode of delivery, and increased peripartum hemorrhage. CONCLUSION: Although oocyte donation is prohibited by German law, many couples go abroad to seek reproductive measures using oocyte donation after former treatment options have failed. OD pregnancies are associated with a high risk of preeclampsia, C-section as mode of delivery, and peripartum hemorrhage. Detailed knowledge of the associated risks is of utmost importance to both the patient and the treating physician and midwife

    Comparison of electrohysterogram signal measured by surface electrodes with different designs: A computational study with dipole band and abdomen models

    Get PDF
    Non-invasive measurement of uterine activity using electrohysterogram (EHG) surface electrodes has been attempted to monitor uterine contraction. This study aimed to computationally compare the performance of acquiring EHG signals using monopolar electrode and three types of Laplacian concentric ring electrodes (bipolar, quasi-bipolar and tri-polar). With the implementation of dipole band model and abdomen model, the performances of four electrodes in terms of the local sensitivity were quantifed by potential attenuation. Furthermore, the efects of fat and muscle thickness on potential attenuation were evaluated using the bipolar and tri-polar electrodes with diferent radius. The results showed that all the four types of electrodes detected the simulated EHG signals with consistency. That the bipolar and tri-polar electrodes had greater attenuations than the others, and the shorter distance between the origin and location of dipole band at 20dB attenuation, indicating that they had relatively better local sensitivity. In addition, ANOVA analysis showed that, for all the electrodes with diferent outer ring radius, the efects of fat and muscle on potential attenuation were signifcant (all p<0.01). It is therefore concluded that the bipolar and tri-polar electrodes had higher local sensitivity than the others, indicating that they can be applied to detect EHG efectively

    Severe fetal growth restriction at 26-32 weeks: key messages from the TRUFFLE study.

    Get PDF
    The Trial of Randomized Umbilical and Fetal Flow in Europe (TRUFFLE) was a prospective, multicenter, unblinded, randomized trial that ran between 1 January 2005 and 1 October 2010 in 20 European centers1. It studied singleton pregnancies at 26–32weeks of gestation with a diagnosis of fetal growth restriction (FGR), defined as abdominal circumference95th percentile). In order to assess whether changes in the fetal ductus venosus (DV) Doppler waveform or short-term variation (STV) on cardiotocography (CTG) should be used as a trigger for delivery in these pregnancies, the 503 included women were randomly allocated to one of three ‘timing-of-delivery’ plans (with 1 : 1 : 1 randomization).</p

    Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode

    Full text link
    The conduction velocity and propagation patterns of Electrohysterogram (EHG) provide fundamental information about uterine electrophysiological condition. The accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations the aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare it with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences among channels in either duration or dominant frequency in the Fast Wave High frequency range were found. Nonetheless, the high pass filtering effect of the BC-EHG records resulted in lower frequency content within the range 0.1 to 0.2 Hz than the bipolar ones. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing uterine electrophysiological condition.The authors are grateful to the Obstetrics Unit of the Hospital Universitario La Fe de Valencia (Valencia, Spain), where the recording sessions were carried out. The work was supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC2010-16945), by the Universitat Politecnica de Valencia (PAID SP20120490) and Generalitat Valenciana (GV/2014/029) and by General Electric Healthcare.Ye Lin, Y.; Alberola Rubio, J.; Prats Boluda, G.; Perales Marin, AJ.; Desantes, D.; Garcia Casado, FJ. (2015). Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode. Annals of Biomedical Engineering. 43(4):968-976. https://doi.org/10.1007/s10439-014-1130-5S968976434Alberola-Rubio, J., G. Prats-Boluda, Y. Ye-Lin, J. Valero, A. Perales, and J. Garcia-Casado. Comparison of non-invasive electrohysterographic recording techniques for monitoring uterine dynamics. Med. Eng. Phys. 35(12):1736–1743, 2013.Besio, W. G., K. Koka, R. Aakula, and W. Dai. Tri-polar concentric ring electrode development for laplacian electroencephalography. IEEE Trans. Biomed. Eng. 53(5):926–933, 2006.Devasahayam, S. R. Signals and Systems in Biomedical Engineering. Berlin: Springer, 2013.Devedeux, D., C. Marque, S. Mansour, G. Germain, and J. Duchene. Uterine electromyography: a critical review. Am. J. Obstet. Gynecol. 169(6):1636–1653, 1993.Estrada, L., A. Torres, J. Garcia-Casado, G. Prats-Boluda, and R. Jane. Characterization of laplacian surface electromyographic signals during isometric contraction in biceps brachii. Conf. Proc. IEEE Eng Med. Biol. Soc. 2013:535–538, 2013.Euliano, T. Y., D. Marossero, M. T. Nguyen, N. R. Euliano, J. Principe, and R. K. Edwards. Spatiotemporal electrohysterography patterns in normal and arrested labor. Am. J. Obstet. Gynecol. 200(1):54–57, 2009.Farina, D., and C. Cescon. Concentric-ring electrode systems for noninvasive detection of single motor unit activity. IEEE Trans. Biomed. Eng. 48(11):1326–1334, 2001.Fele-Zorz, G., G. Kavsek, Z. Novak-Antolic, and F. Jager. A comparison of various linear and non-linear signal processing techniques to separate uterine EMG records of term and pre-term delivery groups. Med. Biol. Eng Comput. 46(9):911–922, 2008.Garfield, R. E., and W. L. Maner. Physiology and electrical activity of uterine contractions. Semin. Cell Dev. Biol. 18(3):289–295, 2007.Garfield, R. E., W. L. Maner, L. B. Mackay, D. Schlembach, and G. R. Saade. Comparing uterine electromyography activity of antepartum patients vs. term labor patients. Am. J. Obstet. Gynecol. 193(1):23–29, 2005.Garfield, R. E., H. Maul, L. Shi, W. Maner, C. Fittkow, G. Olsen, and G. R. Saade. Methods and devices for the management of term and preterm labor. Ann. N. Y. Acad. Sci. 943(1):203–224, 2001.Hassan, M., J. Terrien, C. Muszynski, A. Alexandersson, C. Marque, and B. Karlsson. Better pregnancy monitoring using nonlinear correlation analysis of external uterine electromyography. IEEE Trans. Biomed. Eng. 60(4):1160–1166, 2013.Kaufer, M., L. Rasquinha, and P. Tarjan. Optimization of multi-ring sensing electrode set, Conference proceedings of IEEE Engineering in Medicine and Biology Society, 1990, pp. 612–613.Koka, K., and W. G. Besio. Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes. J. Neurosci. Methods 165(2):216–222, 2007.Lu, C.-C., and P. P. Tarjan. Pasteless, active, concentric ring sensors for directly obtained laplacian cardiac electrograms. J. Med. Biol. Eng. 22(4):199–203, 2002.Lucovnik, M., W. L. Maner, L. R. Chambliss, R. Blumrick, J. Balducci, Z. Novak-Antolic, and R. E. Garfield. Noninvasive uterine electromyography for prediction of preterm delivery. Am. J. Obstet. Gynecol. 204(3):228.e1–228.e10, 2011.Maner, W. L., and R. E. Garfield. Identification of human term and preterm labor using artificial neural networks on uterine electromyography data. Ann. Biomed. Eng. 35(3):465–473, 2007.Maner, W. L., R. E. Garfield, H. Maul, G. Olson, and G. Saade. Predicting term and preterm delivery with transabdominal uterine electromyography. Obstet. Gynecol. 101(6):1254–1260, 2003.Marque, C., J. M. Duchene, S. Leclercq, G. S. Panczer, and J. Chaumont. Uterine EHG processing for obstetrical monitoring. IEEE Trans. Biomed. Eng. 33(12):1182–1187, 1986.Marque, C. K., J. Terrien, S. Rihana, and G. Germain. Preterm labour detection by use of a biophysical marker: the uterine electrical activity. BMC. Pregnancy Childbirth. 7(Suppl1):S5, 2007.Maul, H., W. L. Maner, G. Olson, G. R. Saade, and R. E. Garfield. Non-invasive transabdominal uterine electromyography correlates with the strength of intrauterine pressure and is predictive of labor and delivery. J. Matern. Fetal Neonatal Med. 15(5):297–301, 2004.Miles, A. M., M. Monga, and K. S. Richeson. Correlation of external and internal monitoring of uterine activity in a cohort of term patients. Am. J. Perinatol. 18(3):137–140, 2001.Prats-Boluda, G., J. Garcia-Casado, J. L. Martinez-de-Juan, and Y. Ye-Lin. Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals. Med. Eng. Phys. 33(4):446–455, 2010.Prats-Boluda, G., Y. Ye-Lin, E. Garcia-Breijo, J. Ibañez, and J. Garcia-Casado. Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings. Meas. Sci. Technol. 23(12):1–10, 2012.Rabotti, C., M. Mischi, S. G. Oei, and J. W. Bergmans. Noninvasive estimation of the electrohysterographic action-potential conduction velocity. IEEE Trans. Biomed. Eng. 57(9):2178–2187, 2010.Rabotti, C., S. G. Oei, H. J. van ‘t, and M. Mischi. Electrohysterographic propagation velocity for preterm delivery prediction. Am. J. Obstet. Gynecol. 205(6):e9–e10, 2011.Rooijakkers, M. J., S. Song, C. Rabotti, S. G. Oei, J. W. Bergmans, E. Cantatore, and M. Mischi. Influence of electrode placement on signal quality for ambulatory pregnancy monitoring. Comput. Math. Methods Med. 2014(1):960980, 2014.Schlembach, D., W. L. Maner, R. E. Garfield, and H. Maul. Monitoring the progress of pregnancy and labor using electromyography. Eur. J. Obstet. Gynecol. Reprod. Biol. 144(Suppl1):S33–S39, 2009.Sikora, J., A. Matonia, R. Czabanski, K. Horoba, J. Jezewski, and T. Kupka. Recognition of premature threatening labour symptoms from bioelectrical uterine activity signals. Arch. Perinatal Med. 17(2):97–103, 2011.Terrien, J., C. Marque, and B. Karlsson. Spectral characterization of human EHG frequency components based on the extraction and reconstruction of the ridges in the scalogram, Conference proceedings of IEEE Engineering in Medicine and Biology Society, 2007, pp. 1872–1875.Terrien, J., C. Marque, T. Steingrimsdottir, and B. Karlsson. Evaluation of adaptive filtering methods on a 16 electrode electrohysterogram recorded externally in labor, 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing, 2007, Vol. 16, pp. 135–138.U.S. Preventive Services Task Force. Guide to clinical preventive services: an assessment of the effectiveness of 169 interventions. Baltimore: Willams & Wilkins, 1989

    Phase-rectified signal averaging method to predict perinatal outcome in infants with very preterm fetal growth restriction- a secondary analysis of TRUFFLE-trial

    Get PDF
    BACKGROUND: Phase-rectified signal averaging, an innovative signal processing technique, can be used to investigate quasi-periodic oscillations in noisy, nonstationary signals that are obtained from fetal heart rate. Phase-rectified signal averaging is currently the best method to predict survival after myocardial infarction in adult cardiology. Application of this method to fetal medicine has established significantly better identification than with short-term variation by computerized cardiotocography of growth-restricted fetuses. OBJECTIVE: The aim of this study was to determine the longitudinal progression of phase-rectified signal averaging indices in severely growth-restricted human fetuses and the prognostic accuracy of the technique in relation to perinatal and neurologic outcome. STUDY DESIGN: Raw data from cardiotocography monitoring of 279 human fetuses were obtained from 8 centers that took part in the multicenter European “TRUFFLE” trial on optimal timing of delivery in fetal growth restriction. Average acceleration and deceleration capacities were calculated by phase-rectified signal averaging to establish progression from 5 days to 1 day before delivery and were compared with short-term variation progression. The receiver operating characteristic curves of average acceleration and deceleration capacities and short-term variation were calculated and compared between techniques for short- and intermediate-term outcome. RESULTS: Average acceleration and deceleration capacities and short-term variation showed a progressive decrease in their diagnostic indices of fetal health from the first examination 5 days before delivery to 1 day before delivery. However, this decrease was significant 3 days before delivery for average acceleration and deceleration capacities, but 2 days before delivery for short-term variation. Compared with analysis of changes in short-term variation, analysis of (delta) average acceleration and deceleration capacities better predicted values of Apgar scores <7 and antenatal death (area under the curve for prediction of antenatal death: delta average acceleration capacity, 0.62 [confidence interval, 0.19–1.0]; delta short-term variation, 0.54 [confidence interval, 0.13–0.97]; P=.006; area under the curve for prediction Apgar <7: average deceleration capacity <24 hours before delivery, 0.64 [confidence interval, 0.52–0.76]; short-term variation <24 hours before delivery, 0.53 [confidence interval, 0.40–0.65]; P=.015). Neither phase-rectified signal averaging indices nor short-term variation showed predictive power for developmental disability at 2 years of age (Bayley developmental quotient, <95 or <85). CONCLUSIONS: The phase-rectified signal averaging method seems to be at least as good as short-term variation to monitor progressive deterioration of severely growth-restricted fetuses. Our findings suggest that for short-term outcomes such as Apgar score, phase-rectified signal averaging indices could be an even better test than short-term variation. Overall, our findings confirm the possible value of prospective trials based on phase-rectified signal averaging indices of autonomic nervous system of severely growth-restricted fetuses

    Perinatal and 2-year neurodevelopmental outcome in late preterm fetal compromise: The TRUFFLE 2 randomised trial protocol

    Get PDF
    Introduction Following the detection of fetal growth restriction, there is no consensus about the criteria that should trigger delivery in the late preterm period. The consequences of inappropriate early or late delivery are potentially important yet practice varies widely around the world, with abnormal findings from fetal heart rate monitoring invariably leading to delivery. Indices derived from fetal cerebral Doppler examination may guide such decisions although there are few studies in this area. We propose a randomised, controlled trial to establish the optimum method of timing delivery between 32 weeks and 36 weeks 6 days of gestation. We hypothesise that delivery on evidence of cerebral blood flow redistribution reduces a composite of perinatal poor outcome, death and short-term hypoxia-related morbidity, with no worsening of neurodevelopmental outcome at 2 years. Methods and analysis Women with non-anomalous singleton pregnancies 32+0 to 36+6 weeks of gestation in whom the estimated fetal weight or abdominal circumference is &lt;10th percentile or has decreased by 50 percentiles since 18-32 weeks will be included for observational data collection. Participants will be randomised if cerebral blood flow redistribution is identified, based on umbilical to middle cerebral artery pulsatility index ratio values. Computerised cardiotocography (cCTG) must show normal fetal heart rate short term variation (≥4.5 msec) and absence of decelerations at randomisation. Randomisation will be 1:1 to immediate delivery or delayed delivery (based on cCTG abnormalities or other worsening fetal condition). The primary outcome is poor condition at birth and/or fetal or neonatal death and/or major neonatal morbidity, the secondary non-inferiority outcome is 2-year infant general health and neurodevelopmental outcome based on the Parent Report of Children's Abilities-Revised questionnaire. Ethics and dissemination The Study Coordination Centre has obtained approval from London-Riverside Research Ethics Committee (REC) and Health Regulatory Authority (HRA). Publication will be in line with NIHR Open Access policy. Trial registration number Main sponsor: Imperial College London, Reference: 19QC5491. Funders: NIHR HTA, Reference: 127 976. Study coordination centre: Imperial College Healthcare NHS Trust, Du Cane Road, London, W12 0HS with Centre for Trials Research, College of Biomedical &amp; Life Sciences, Cardiff University. IRAS Project ID: 266 400. REC reference: 20/LO/0031. ISRCTN registry: 76 016 200

    Comparison of placental growth factor and fetal flow Doppler ultrasonography to identify fetal adverse outcomes in women with hypertensive disorders of pregnancy: an observational study.

    Get PDF
    BACKGROUND: Hypertensive disorders of pregnancy and intrauterine growth restriction (IUGR) are leading causes of maternal and perinatal morbidity and mortality. Failure to detect intrauterine growth restriction in women at high risk has been highlighted as a significant avoidable cause of serious fetal outcome. In this observational study we compare fetal flow using Doppler ultrasonography with a new test for placental growth factor (PlGF) to predict fetal adverse events. METHODS: Eighty-nine women with hypertensive disorders of pregnancy (24 with chronic hypertension, 17 with gestational hypertension, 12 with HELLP syndrome, 19 with preeclampsia and 17 with superimposed preeclampsia) were enrolled. A single maternal blood sample to measure free PlGF (Alere Triage) taken before 35 weeks of pregnancy was compared to the last Doppler ultrasound measurement of fetal flow before delivery. PlGF was classified as normal (PlGF>/=100 pg/ml), low (12<PlGF<100) or very low (PlGF</=12 pg/ml). A positive test for abnormal fetal flow was defined as either signs of centralisation of the fetal circulation or diastolic block or reverse flow in the umbilical artery or descending aorta; this was a criterion for delivery. Fetal outcomes were intrauterine growth restriction and birth before 37 weeks of pregnancy. RESULTS: In total 61/89 women had a preterm birth and 22 infants had IUGR. Of those who delivered preterm, 20/20 women with abnormal fetal flow and 36/41 (87.8%) women with normal fetal flow had low or very low PlGF. Of those infants with IUGR, 22/22 had low or very low maternal PlGF and 10/22 had abnormal fetal flow. CONCLUSIONS: PlGF may provide useful information before 35th gestational week to identify fetuses requiring urgent delivery, and those at risk of later adverse outcomes not identified by fetal flow Doppler ultrasonography
    corecore