644 research outputs found

    Prognostic implications of left ventricular global longitudinal strain in heart failure patients with narrow QRS complex treated with cardiac resynchronization therapy: a subanalysis of the randomized EchoCRT trial

    Get PDF
    Aim: Left ventricular (LV) global longitudinal strain (GLS) reflects LV systolic function and correlates inversely with the extent of LV myocardial scar and fibrosis. The present subanalysis of the Echocardiography Guided CRT trial investigated the prognostic value of LV GLS in patients with narrow QRS complex. Methods and results: Left ventricular (LV) global longitudinal strain (GLS) was measured on the apical 2-, 4- and 3-chamber views using speckle tracking analysis. Measurement of baseline LV GLS was feasible in 755 patients (374 with cardiac resynchronization therapy (CRT)-ON and 381 with CRT-OFF). The median value of LV GLS in the overall population was 7.9%, interquartile range 6.2–10.1%. After a mean follow-up period of 19.4 months, 95 patients in the CRT-OFF group and 111 in the CRT-ON group reached the combined primary endpoint of all-cause mortality and heart failure hospitalization. Each 1% absolute unit decrease in LV GLS was independently associated with 11% increase in the risk to reach the primary endpoint (Hazard ratio 1.11; 95% confidence interval 95% 1.04–1.17, P < 0.001), after adjusting for ischaemic cardiomyopathy and randomization treatment among other clinically relevant variables. When categorizing patients according to quartiles of LV GLS, the primary endpoint occurred more frequently in patients in the lowest quartile (<6.2%) treated with CRT-ON vs. CRT-OFF (45.6% vs. 28.7%, P = 0.009) whereas, no differences were observed in patients with LV GLS ≥6.2% treated with CRT-OFF vs. CRT-ON (23.7% vs. 24.5%, respectively; P  = 0.62). Conclusion: Low LV GLS is associated with poor outcome in heart failure patients with QRS width <130 ms, independent of randomization to CRT or not. Importantly, in the group of patients with the lowest LV GLS quartile, CRT may have a detrimental effect on clinical outcomes

    Incident venous thromboembolic events in the Prospective Study of Pravastatin in the Elderly at Risk (PROSPER)

    Get PDF
    <p>Background: Venous thromboembolic events (VTE), including deep venous thrombosis and pulmonary embolism, are common in older age. It has been suggested that statins might reduce the risk of VTE however positive results from studies of middle aged subjects may not be generalisable to elderly people. We aimed to determine the effect of pravastatin on incident VTE in older people; we also studied the impact of clinical and plasma risk variables.</p> <p>Methods: This study was an analysis of incident VTE using data from the Prospective Study of Pravastatin in the Elderly at Risk (PROSPER), a randomized, double-blind, placebo-controlled trial of pravastatin in men and women aged 70-82. Mean follow-up was 3.2 years. Risk for VTE was examined in non-warfarin treated pravastatin (n = 2834) and placebo (n = 2865) patients using a Cox's proportional hazard model, and the impact of other risk factors assessed in a multivariate forward stepwise regression analysis. Baseline clinical characteristics, blood biochemistry and hematology variables, plasma levels of lipids and lipoproteins, and plasma markers of inflammation and adiposity were compared. Plasma markers of thrombosis and hemostasis were assessed in a nested case (n = 48) control (n = 93) study where the cohort was those participants, not on warfarin, for whom data were available.</p> <p>Results: There were 28 definite cases (1.0%) of incident VTE in the pravastatin group recipients and 20 cases (0.70%) in placebo recipients. Pravastatin did not reduce VTE in PROSPER compared to placebo [unadjusted hazard ratio (95% confidence interval) 1.42 (0.80, 2.52) p = 0.23]. Higher body mass index (BMI) [1.09 (1.02, 1.15) p = 0.0075], country [Scotland vs Netherlands 4.26 (1.00, 18.21) p = 0.050 and Ireland vs Netherlands 6.16 (1.46, 26.00) p = 0.013], lower systolic blood pressure [1.35 (1.03, 1.75) p = 0.027] and lower baseline Mini Mental State Examination (MMSE) score [1.19 (1.01, 1.41) p = 0.034] were associated with an increased risk of VTE, however only BMI, country and systolic blood pressure remained significant on multivariate analysis. In a nested case control study of definite VTE, plasma Factor VIII levels were associated with VTE [1.52 (1.01, 2.28), p = 0.044]. However no other measure of thrombosis and haemostasis was associated with increased risk of VTE.</p> <p>Conclusions: Pravastatin does not prevent VTE in elderly people at risk of vascular disease. Blood markers of haemostasis and inflammation are not strongly predictive of VTE in older age however BMI, country and lower systolic blood pressure are independently associated with VTE risk.</p&gt

    The effect of QRS duration on cardiac resynchronization therapy in patients with a narrow QRS complex: a subgroup analysis of the EchoCRT trial

    Get PDF
    Aims In EchoCRT, a randomized trial evaluating the effect of cardiac resynchronization therapy (CRT) in patients with a QRS duration of <130 ms and echocardiographic evidence of left ventricular dyssynchrony, the primary outcome occurred more frequently in the CRT when compared with the control group. According to current heart failure guidelines, CRT is recommended in patients with a QRS duration of ≥120 ms. However, there is some ambiguity from clinical trial data regarding the benefit of patients with a QRS duration of 120-130 ms. Methods and results The main EchoCRT trial was prematurely terminated due to futility. For the current subgroup analysis we compared data for CRT-ON vs. -OFF in patients with QRS < 120 (n = 661) and QRS 120-130 ms (n = 139). On uni- and multivariable analyses, no significant interaction was observed between the two groups and randomized treatment for the primary or any of the secondary endpoints. On multivariable analysis, a higher risk for the primary endpoint was observed in patients with a QRS duration of 120-130 ms randomized to CRT-ON vs. CRT-OFF (hazard ratio 2.18, 95% CI 1.02-4.65; P = 0.044). However, no statistically significant interaction, compared with patients with QRS < 120 ms randomized to CRT-ON vs. CRT-OFF, was noted (P-interaction = 0.160). Conclusions In this pre-specified subgroup analysis of EchoCRT, no benefit of CRT was evident in patients with a QRS duration of 120-130 ms. These data further question the usefulness of CRT in this patient populatio

    Evaluating implicit feedback models using searcher simulations

    Get PDF
    In this article we describe an evaluation of relevance feedback (RF) algorithms using searcher simulations. Since these algorithms select additional terms for query modification based on inferences made from searcher interaction, not on relevance information searchers explicitly provide (as in traditional RF), we refer to them as implicit feedback models. We introduce six different models that base their decisions on the interactions of searchers and use different approaches to rank query modification terms. The aim of this article is to determine which of these models should be used to assist searchers in the systems we develop. To evaluate these models we used searcher simulations that afforded us more control over the experimental conditions than experiments with human subjects and allowed complex interaction to be modeled without the need for costly human experimentation. The simulation-based evaluation methodology measures how well the models learn the distribution of terms across relevant documents (i.e., learn what information is relevant) and how well they improve search effectiveness (i.e., create effective search queries). Our findings show that an implicit feedback model based on Jeffrey's rule of conditioning outperformed other models under investigation

    Authentication of Antibiotics Using Portable Near-Infrared Spectroscopy and Multivariate Data Analysis

    Get PDF
    Counterfeit medicines represent a global public health threat warranting the development of accurate, rapid, and nondestructive methods for their identification. Portable near-infrared (NIR) spectroscopy offers this advantage. This work sheds light on the potential of combining NIR spectroscopy with principal component analysis (PCA) and soft independent modelling of class analogy (SIMCA) for authenticating branded and generic antibiotics. A total of 23 antibiotics were measured “nondestructively” using a portable NIR spectrometer. The antibiotics corresponded to six different active pharmaceutical ingredients being: amoxicillin trihydrate and clavulanic acid, azithromycin dihydrate, ciprofloxacin hydrochloride, doxycycline hydrochloride, and ofloxacin. NIR spectra were exported into Matlab R2018b where data analysis was applied. The results showed that the NIR spectra of the medicines showed characteristic features that corresponded to the main excipient(s). When combined with PCA, NIR spectroscopy could distinguish between branded and generic medicines and could classify medicines according to their manufacturing sources. The PCA scores showed the distinct clusters corresponding to each group of antibiotics, whereas the loadings indicated which spectral features were significant. SIMCA provided more accurate classification over PCA for all antibiotics except ciprofloxacin which products shared many overlapping excipients. In summary, the findings of the study demonstrated the feasibility of portable NIR as an initial method for screening antibiotics

    Cardiac resynchronization therapy in patients with heart failure and narrow QRS complexes

    Get PDF
    Background: Cross correlation analysis (CCA) using tissue Doppler imaging has been shown to be associated with outcome after cardiac resynchronization therapy (CRT) in patients with heart failure (HF) with wide QRS. However, its significance in patients with narrow QRS treated with CRT is unknown. Objectives: The aim of the current study was to investigate the association of mechanical activation delay by CCA with study outcome in patients with HF enrolled in the EchoCRT trial. Methods: Baseline CCA could be performed from tissue Doppler imaging in the apical views in 807 of 809 (99.7%) enrolled patients, and 6-month follow-up could be performed in 610 of 635 (96%) patients with available echocardiograms. Patients with a pre-specified maximal activation delay ≥35 ms were considered to have significant delay. The study outcome was HF hospitalization or death. Results: Of 807 patients, 375 (46%) did not have delayed mechanical activation at baseline by CCA. Patients without delayed mechanical activation who were randomized to CRT-On compared with CRT-Off had an increased risk of poor outcome (hazard ratio: 1.70; 95% confidence interval: 1.13 to 2.55; p = 0.01) with a significant interaction term (p = 0.04) between delayed mechanical activation and device randomization for the endpoint. Among patients with paired baseline and follow-up data with no events before 6-month follow-up (n = 541), new-onset delayed mechanical activation in the CRT-On group showed a significant increase in unfavorable events (hazard ratio: 3.73; 95% confidence interval: 1.15 to 12.14; p = 0.03). Conclusions: In the EchoCRT population, absence of delayed mechanical activation by CCA was significantly associated with poor outcomes, possibly due to the onset of new delayed mechanical activation with CRT pacing. (Echocardiography Guided Cardiac Resynchronization Therapy [EchoCRT] Trial; NCT00683696)

    Bose-Einstein Correlations of Three Charged Pions in Hadronic Z^0 Decays

    Get PDF
    Bose-Einstein Correlations (BEC) of three identical charged pions were studied in 4 x 10^6 hadronic Z^0 decays recorded with the OPAL detector at LEP. The genuine three-pion correlations, corrected for the Coulomb effect, were separated from the known two-pion correlations by a new subtraction procedure. A significant genuine three-pion BEC enhancement near threshold was observed having an emitter source radius of r_3 = 0.580 +/- 0.004 (stat.) +/- 0.029 (syst.) fm and a strength of \lambda_3 = 0.504 +/- 0.010 (stat.) +/- 0.041 (syst.). The Coulomb correction was found to increase the \lambda_3 value by \~9% and to reduce r_3 by ~6%. The measured \lambda_3 corresponds to a value of 0.707 +/- 0.014 (stat.) +/- 0.078 (syst.) when one takes into account the three-pion sample purity. A relation between the two-pion and the three-pion source parameters is discussed.Comment: 19 pages, LaTeX, 5 eps figures included, accepted by Eur. Phys. J.

    Pilot randomized trial of therapeutic hypothermia with serial cranial ultrasound and 18-22 month follow-up for neonatal encephalopathy in a low resource hospital setting in Uganda: study protocol

    Get PDF
    Background: There is now convincing evidence that in industrialized countries therapeutic hypothermia for perinatal asphyxial encephalopathy increases survival with normal neurological function. However, the greatest burden of perinatal asphyxia falls in low and mid-resource settings where it is unclear whether therapeutic hypothermia is safe and effective.Aims: Under the UCL Uganda Women's Health Initiative, a pilot randomized controlled trial in infants with perinatal asphyxia was set up in the special care baby unit in Mulago Hospital, a large public hospital with similar to 20,000 births in Kampala, Uganda to determine:(i) The feasibility of achieving consent, neurological assessment, randomization and whole body cooling to a core temperature 33-34 degrees C using water bottles(ii) The temperature profile of encephalopathic infants with standard care(iii) The pattern, severity and evolution of brain tissue injury as seen on cranial ultrasound and relation with outcome(iv) The feasibility of neurodevelopmental follow-up at 18-22 months of ageMethods/Design: Ethical approval was obtained from Makerere University and Mulago Hospital. All infants were in-born. Parental consent for entry into the trial was obtained. Thirty-six infants were randomized either to standard care plus cooling (target rectal temperature of 33-34 degrees C for 72 hrs, started within 3 h of birth) or standard care alone. All other aspects of management were the same. Cooling was performed using water bottles filled with tepid tap water (25 degrees C). Rectal, axillary, ambient and surface water bottle temperatures were monitored continuously for the first 80 h. Encephalopathy scoring was performed on days 1-4, a structured, scorable neurological examination and head circumference were performed on days 7 and 17. Cranial ultrasound was performed on days 1, 3 and 7 and scored. Griffiths developmental quotient, head circumference, neurological examination and assessment of gross motor function were obtained at 18-22 months.Discussion: We will highlight differences in neonatal care and infrastructure that need to be taken into account when considering a large safety and efficacy RCT of therapeutic hypothermia in low and mid resource settings in the future

    Quantum state preparation and macroscopic entanglement in gravitational-wave detectors

    Full text link
    Long-baseline laser-interferometer gravitational-wave detectors are operating at a factor of 10 (in amplitude) above the standard quantum limit (SQL) within a broad frequency band. Such a low classical noise budget has already allowed the creation of a controlled 2.7 kg macroscopic oscillator with an effective eigenfrequency of 150 Hz and an occupation number of 200. This result, along with the prospect for further improvements, heralds the new possibility of experimentally probing macroscopic quantum mechanics (MQM) - quantum mechanical behavior of objects in the realm of everyday experience - using gravitational-wave detectors. In this paper, we provide the mathematical foundation for the first step of a MQM experiment: the preparation of a macroscopic test mass into a nearly minimum-Heisenberg-limited Gaussian quantum state, which is possible if the interferometer's classical noise beats the SQL in a broad frequency band. Our formalism, based on Wiener filtering, allows a straightforward conversion from the classical noise budget of a laser interferometer, in terms of noise spectra, into the strategy for quantum state preparation, and the quality of the prepared state. Using this formalism, we consider how Gaussian entanglement can be built among two macroscopic test masses, and the performance of the planned Advanced LIGO interferometers in quantum-state preparation
    corecore