2,521 research outputs found

    Multi-strange baryon measurements at LHC energies, with the ALICE experiment

    Full text link
    The status of the charged multi-strange baryon analysis (Xi-, anti-Xi+, Omega-, anti-Omega+) at LHC energies is presented. This report is based on the results obtained with ALICE (A Large Ion Collider Experiment), profiting from the characteristic cascade-decay topology. A special attention is drawn to the early pp data-taking period (2009-2010) and subsequently, on the uncorrected pT-spectra extracted at mid-rapidity for centre of mass energies of 0.9 TeV and 7 TeV.Comment: 4 pages, 5 figures, Hot Quarks 2010 proceedings, La Londe Les Maures, France, June 2010 (to be published in Journal of Physics: Conference Series

    Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes

    Get PDF
    Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stopping power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeteris applied for reconstruction of the tracks and energies of individual high energy protons. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.Comment: 21 pages, 8 figure

    Constraining the magnitude of the Chiral Magnetic Effect with Event Shape Engineering in Pb-Pb collisions at sNN\sqrt{s_{\rm NN}} = 2.76$ TeV

    Full text link
    In ultrarelativistic heavy-ion collisions, the event-by-event variation of the elliptic flow v2v_2 reflects fluctuations in the shape of the initial state of the system. This allows to select events with the same centrality but different initial geometry. This selection technique, Event Shape Engineering, has been used in the analysis of charge-dependent two- and three-particle correlations in Pb-Pb collisions at sNN=2.76\sqrt{s_{_{\rm NN}}} =2.76 TeV. The two-particle correlator cos(φαφβ)\langle \cos(\varphi_\alpha - \varphi_\beta) \rangle, calculated for different combinations of charges α\alpha and β\beta, is almost independent of v2v_2 (for a given centrality), while the three-particle correlator cos(φα+φβ2Ψ2)\langle \cos(\varphi_\alpha + \varphi_\beta - 2\Psi_2) \rangle scales almost linearly both with the event v2v_2 and charged-particle pseudorapidity density. The charge dependence of the three-particle correlator is often interpreted as evidence for the Chiral Magnetic Effect (CME), a parity violating effect of the strong interaction. However, its measured dependence on v2v_2 points to a large non-CME contribution to the correlator. Comparing the results with Monte Carlo calculations including a magnetic field due to the spectators, the upper limit of the CME signal contribution to the three-particle correlator in the 10-50% centrality interval is found to be 26-33% at 95% confidence level.Comment: 20 pages, 6 captioned figures, 1 tables, authors from page 15, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/382

    Energy dependence of exclusive J/ψJ/\psi photoproduction off protons in ultra-peripheral p-Pb collisions at sNN\sqrt{s_{\rm{NN}}} = 5.02 TeV

    Full text link
    The ALICE Collaboration has measured the energy dependence of exclusive photoproduction of J/ψJ/\psi vector mesons off proton targets in ultra-peripheral p-Pb collisions at a centre-of-mass energy per nucleon pair sNN=5.02\sqrt{s_{\rm NN}} = 5.02 TeV. The e+^+e^- and μ+μ\mu^+\mu^- decay channels are used to measure the cross section as a function of the rapidity of the J/ψJ/\psi in the range 2.5<y<2.7-2.5 < y < 2.7, corresponding to an energy in the γ\gammap centre-of-mass in the interval 40<Wγp<55040 < W_{\gamma\mathrm{p}}<550 GeV. The measurements, which are consistent with a power law dependence of the exclusive J/ψJ/\psi photoproduction cross section, are compared to previous results from HERA and the LHC and to several theoretical models. They are found to be compatible with previous measurements.Comment: 25 pages, 3 captioned figures, 3 tables, authors from page 19, published version, figures at http://alice-publications.web.cern.ch/node/455

    Measurement of the production of charm jets tagged with D0^{0} mesons in pp collisions at s\sqrt{s}= 7 TeV

    Full text link
    The production of charm jets in proton-proton collisions at a center-of-mass energy of s=7\sqrt{s}=7 TeV was measured with the ALICE detector at the CERN Large Hadron Collider. The measurement is based on a data sample corresponding to a total integrated luminosity of 6.236.23 nb1{\rm nb}^{-1}, collected using a minimum-bias trigger. Charm jets are identified by the presence of a D0^0 meson among their constituents. The D0^0 mesons are reconstructed from their hadronic decay D0^0\rightarrowKπ+^{-}\pi^{+}. The D0^0-meson tagged jets are reconstructed using tracks of charged particles (track-based jets) with the anti-kTk_{\mathrm{T}} algorithm in the jet transverse momentum range 5<pT,jetch<305<p_{\rm{T,jet}}^{\mathrm{ch}}<30 GeV/c{\rm GeV/}c and pseudorapidity ηjet<0.5|\eta_{\rm jet}|<0.5. The fraction of charged jets containing a D0^0-meson increases with pT,jetchp_{\rm{T,jet}}^{\rm{ch}} from 0.042±0.004(stat)±0.006(syst)0.042 \pm 0.004\, \mathrm{(stat)} \pm 0.006\, \mathrm{(syst)} to 0.080±0.009(stat)±0.008(syst)0.080 \pm 0.009\, \rm{(stat)} \pm 0.008\, \rm{(syst)}. The distribution of D0^0-meson tagged jets as a function of the jet momentum fraction carried by the D0^0 meson in the direction of the jet axis (zchz_{||}^{\mathrm{ch}}) is reported for two ranges of jet transverse momenta, 5<pT,jetch<155<p_{\rm{T,jet}}^{\rm{ch}}<15 GeV/c{\rm GeV/}c and 15<pT,jetch<3015<p_{\rm{T,jet}}^{\rm{ch}}<30 GeV/c{\rm GeV/}c in the intervals 0.2<zch<1.00.2<z_{||}^{\rm{ch}}<1.0 and 0.4<zch<1.00.4<z_{||}^{\rm{ch}}<1.0, respectively. The data are compared with results from Monte Carlo event generators (PYTHIA 6, PYTHIA 8 and Herwig 7) and with a Next-to-Leading-Order perturbative Quantum Chromodynamics calculation, obtained with the POWHEG method and interfaced with PYTHIA 6 for the generation of the parton shower, fragmentation, hadronisation and underlying event.Comment: 29 pages, 8 captioned figures, 3 tables, authors from page 24, published version, figures at http://alice-publications.web.cern.ch/node/525

    Software environment for controlling and re-configuration of Xilinx Virtex FPGAs – TWEPP-07

    Get PDF
    The Time Projection Chamber is one of the detectors of the ALICE experiment, that is currently being commissioned at the Large Hadron Collider at CERN. The Detector Control System is used for control and monitoring of the system. For the TPC Front-End Electronics (FEE) the control node is a Readout Control Unit that communicates to higher layers via Ethernet, using the standard framework DIM. The Readout Control Unit is equipped with commercial SRAM based FPGAs that will experience errors due to the radiation environment they are operating in. This article will present the implemented hardware solution for error correction and will focus on the software environment for configuration and controlling of the system – TWEPP-07

    The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

    Get PDF
    The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.Comment: 55 pages, 82 figure
    corecore