46 research outputs found

    A Real-Time Ball Detection Approach Using Convolutional Neural Networks

    Get PDF
    Ball detection is one of the most important tasks in the context of soccer-playing robots. The ball is a small moving object which can be blurred and occluded in many situations. Several neural network based methods with different architectures are proposed to deal with the ball detection. However, they are either neglecting to consider the computationally low resources of humanoid robots or highly depend on manually-tuned heuristic methods to extract the ball candidates. In this paper, we propose a new ball detection method for low-cost humanoid robots that can detect most soccer balls with a high accuracy rate of up to 97.17%. The proposed method is divided into two steps. First, some coarse regions that may contain a full ball are extracted using an iterative method employing an efficient integral image based feature. Then they are fed to a light-weight convolutional neural network to finalize the bounding box of a ball. We have evaluated the proposed approach using a comprehensive dataset and the experimental results show the efficiency of our method

    Pragmatic approach to nutrition in the ICU: Expert opinion regarding which calorie protein target

    Get PDF
    BACKGROUND & AIMS:Since the publications of the ESPEN guidelines on enteral and parenteral nutrition in ICU, numerous studies have added information to assist the nutritional management of critically ill patients regarding the recognition of the right population to feed, the energy-protein targeting, the route and the timing to start. METHODS: We reviewed and discussed the literature related to nutrition in the ICU from 2006 until October 2013. RESULTS: To identify safe, minimal and maximal amounts for the different nutrients and at the different stages of the acute illness is necessary. These amounts might be specific for different phases in the time course of the patient's illness. The best approach is to target the energy goal defined by indirect calorimetry. High protein intake (1.5 g/kg/d) is recommended during the early phase of the ICU stay, regardless of the simultaneous calorie intake. This recommendation can reduce catabolism. Later on, high protein intake remains recommended, likely combined with a sufficient amount of energy to avoid proteolysis. CONCLUSIONS: Pragmatic recommendations are proposed to practically optimize nutritional therapy based on recent publications. However, on some issues, there is insufficient evidence to make expert recommendations

    Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (CO<sub>PAC</sub>) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (CO<sub>AP</sub>) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using CO<sub>PAC </sub>as the method of reference.</p> <p>Methods</p> <p>We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. CO<sub>PAC </sub>measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while CO<sub>AP </sub>values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman.</p> <p>Results</p> <p>A total of 164 coupled measurements were obtained. Absolute values of CO<sub>PAC </sub>ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between CO<sub>PAC </sub>and CO<sub>AP </sub>for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between CO<sub>PAC </sub>and CO<sub>AP </sub>was 49.3%. The bias between percentage changes in CO<sub>PAC </sub>(ΔCO<sub>PAC</sub>) and percentage changes in CO<sub>AP </sub>(ΔCO<sub>AP</sub>) for consecutive measurements was -0.70% ± 32.28%. CO<sub>PAC </sub>and CO<sub>AP </sub>showed a Pearson correlation coefficient of 0.58 (<it>p </it>< 0.01), while the correlation coefficient between ΔCO<sub>PAC </sub>and ΔCO<sub>AP </sub>was 0.46 (<it>p </it>< 0.01).</p> <p>Conclusion</p> <p>Although the CO<sub>AP </sub>algorithm shows a minimal bias with CO<sub>PAC </sub>over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03) failed to demonstrate an acceptable accuracy in comparison to the clinical standard of cardiac output determination.</p

    Anxiety disorders in headache patients in a specialised clinic: prevalence and symptoms in comparison to patients in a general neurological clinic

    Get PDF
    Data from several studies indicate an association of headache with anxiety disorders. In this study, we assessed and differentiated anxiety disorders in 100 headache patients by using the PSWQ (Penn State Worry Questionnaire) screening tool for generalised anxiety disorder (GAD) and the ACQ (Agoraphobic Cognitions Questionnaire) and BSQ (Body Sensation Questionnaire) for panic disorder (PD). Control groups were constructed: (1) on the basis of epidemiological studies on PD and GAD in the general population and (2) by including neurological patients. 37.0% of headache patients had a GAD. 27% of headache patients met the score for PD in the BSQ, 4.0% in the ACQ. Significant results were obtained in comparison to the general population (p < 0.001) and with regard to GAD in comparison with a sample of neurological patients (p < 0.005). The BSQ significantly correlated with the number of medication days (p < 0.005). The results confirm the increased prevalence of GAD in headache patients. PD seems to increase the risk of medication overuse

    Information Display Protocol

    Get PDF
    Objective: Human Factors Engineers and air traffic control Subject Matter Experts (SMEs) from the Federal Aviation Administration (FAA) developed a protocol to support in decisions on how to present needed information on the en route controller\u2019s visual displays. The protocol provides guidance for determining the criticality of the information and uses this criticality to determine where and how the information should be displayed. Background: Human Factors Engineers and air traffic control SMEs developed and validated the protocol with current and upcoming FAA Next Generation Air Transportation System informational items and scenarios. Application: The model provides a systematic method for integrating the informational needs of controllers and supports the decision process for designing air traffic control displays
    corecore