266 research outputs found

    Recurrence of pericarditis after influenza vaccination: a case report and review of the literature

    Get PDF
    BACKGROUND: This case report describes a patient with pericarditis likely attributed to influenza vaccination (positive rechallenge), with a literature review. CASE PRESENTATION: A 87-year old patient developed pericarditis after influenza vaccination, with acute chest pain, without ECG abnormalities or increased cardiac enzyme levels. Echocardiogram showed moderate pericardial effusion. Recovery was obtained through steroids One year later, few days after re-immunization, the patient experienced the same symptoms and was admitted to hospital with diagnosis of recurrence of pericarditis with severe pericardial effusion, again treated with steroids. Other possible causes were ruled out and the cardiologist recommended against influenza vaccinations in the future; the patient did not experience recurrence of pericarditis in the following 6 years. Cases of pericarditis following influenza immunization in the literature were also reviewed. CONCLUSIONS: Pericarditis following immunization for influenza is very rarely reported in the literature. In a few cases, influenza vaccination seems likely responsible. We suggest considering recent immunization in patient's history as part of the differential diagnosis in elderly with chest pain

    A Historical Perspective of Cardiac Implantable Electronic Device Infection: How a Menace Can Drive Technological and Clinical Improvement

    Get PDF
    In recent decades there has been a relevant increase in the implantation rate of cardiac implantable electronic devices (CIEDs), albeit with relevant geographical inhomogeneities. Despite the positive impact on clinical outcomes, the possibility of major complications is not negligible, particularly with respect to CIED infections. CIED infections significantly affect morbidity and mortality, especially in instances of delayed diagnosis and appropriate treatment. In the present review, we will start to depict the factors underlying the development of CIED infection as well as the difficulties related to its diagnosis and treatment. We will explain the reasons underlying the need to focus on prophylaxis rather than treatment, in view of the poor outcomes despite improvements in lead extraction procedures. This will lead to the consideration of management of this complication in a hub-spoke manner, and to our analysis of the several technological and procedural improvements developed to minimize this complication. These include prolongation of CIED longevity, the development of leadless devices, and integrated prophylactic approaches. We will conclude with a discussion regarding new devices and strategies under development. This complete excursus will provide the reader with a new perspective on how a major complication can drive technological improvements

    Validation of a New and Straightforward Algorithm to Evaluate Signal Quality during ECG Monitoring with Wearable Devices Used in a Clinical Setting

    Get PDF
    Background: Wearable devices represent a new approach for monitoring key clinical parameters, such as ECG signals, for research and health purposes. These devices could outcompete medical devices in terms of affordability and use in out-clinic settings, allowing remote monitoring. The major limitation, especially when compared to implantable devices, is the presence of artifacts. Several authors reported a relevant percentage of recording time with poor/unusable traces for ECG, potentially hampering the use of these devices for this purpose. For this reason, it is of the utmost importance to develop a simple and inexpensive system enabling the user of the wearable devices to have immediate feedback on the quality of the acquired signal, allowing for real-time correction. Methods: A simple algorithm that can work in real time to verify the quality of the ECG signal (acceptable and unacceptable) was validated. Based on simple statistical parameters, the algorithm was blindly tested by comparison with ECG tracings previously classified by two expert cardiologists. Results: The classifications of 7200 10s-signal samples acquired on 20 patients with a commercial wearable ECG monitor were compared. The algorithm has an overall efficiency of approximately 95%, with a sensitivity of 94.7% and a specificity of 95.3%. Conclusions: The results demonstrate that even a simple algorithm can be used to classify signal coarseness, and this could allow real-time intervention by the subject or the technician

    The effects of gender on electrical therapies for the heart: physiology, epidemiology, and access to therapies: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC)

    Get PDF
    The difference between men and women is clear even just by looking at an electrocardiogram: females present higher resting heart rate, a shorter QRS complex length and greater corrected QT interval. The development of these differences from pubertal age onward suggests that sexual hormones play a key role, although their effect is far from being completely understood. Different incidences between sexes have been reported for many arrhythmias, both ventricular and supraventricular, and also for sudden cardiac death. Moreover, arrhythmias are an important issue during pregnancy, both for diagnosis and treatment. Interestingly, cardiovascular structural and electrophysiological remodelling promoted by exercise training enhances this 'gender effect'. Despite all these relevant issues, we lack gender specific recommendations in the current guidelines for electrical therapies for heart rhythm disorders and heart failure. Even more, we continue to see that fewer women are included in clinical trials and are less referred than men for these treatments

    Drug management of atrial fibrillation in light of guidelines and current evidence: an Italian Survey on behalf of Italian Association of Arrhythmology and Cardiac Pacing

    Get PDF
    AimAtrial fibrillation is a multifaceted disease requiring personalized treatment, in accordance with current ESC guidelines. Despite a wide range of literature, we still have various aspects dividing the opinion of the experts in rate control, rhythm control and thromboembolic prophylaxis. The aim of this survey was to provide a country-wide picture of current practice regarding atrial fibrillation pharmacological management according to a patient's characteristics.MethodsData were collected using an in-person survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing.ResultsWe collected data from 106 physicians, working in 72 Italian hospitals from 15 of 21 regions. Our work evidenced a high inhomogeneity in atrial fibrillation management regarding rhythm control, rate control and thromboembolic prophylaxis in both acute and chronic patients. This element was more pronounced in settings in which literature shows a lack of evidence and, consequently, the indications provided by the guidelines are weak or absent.ConclusionThis National survey evidenced a high inhomogeneity in current approaches adopted for atrial fibrillation management by a sample of Italian cardiologist experts in arrhythmia management. Further studies are needed to explore if these divergences are associated with different long-term outcomes

    Optimizing indices of atrial fibrillation susceptibility and burden to evaluate atrial fibrillation severity, risk and outcomes.

    Get PDF
    Atrial fibrillation (AF) has heterogeneous patterns of presentation concerning symptoms, duration of episodes, AF burden, and the tendency to progress towards the terminal step of permanent AF. AF is associated with a risk of stroke/thromboembolism traditionally considered dependent on patient-level risk factors rather than AF type, AF burden, or other characterizations. However, the time spent in AF appears related to an incremental risk of stroke, as suggested by the higher risk of stroke in patients with clinical AF vs. subclinical episodes and in patients with non-paroxysmal AF vs. paroxysmal AF. In patients with device-detected atrial tachyarrhythmias, AF burden is a dynamic process with potential transitions from a lower to a higher maximum daily arrhythmia burden, thus justifying monitoring its temporal evolution. In clinical terms, the appearance of the first episode of AF, the characterization of the arrhythmia in a specific AF type, the progression of AF, and the response to rhythm control therapies, as well as the clinical outcomes, are all conditioned by underlying heart disease, risk factors, and comorbidities. Improved understanding is needed on how to monitor and modulate the effect of factors that condition AF susceptibility and modulate AF-associated outcomes. The increasing use of wearables and apps in practice and clinical research may be useful to predict and quantify AF burden and assess AF susceptibility at the individual patient level. This may help us reveal why AF stops and starts again, or why AF episodes, or burden, cluster. Additionally, whether the distribution of burden is associated with variations in the propensity to thrombosis or other clinical adverse events. Combining the improved methods for data analysis, clinical and translational science could be the basis for the early identification of the subset of patients at risk of progressing to a longer duration/higher burden of AF and the associated adverse outcomes

    The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC)

    Get PDF
    Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects
    corecore