269 research outputs found

    A validated stability-indicating HPLC method for determination of varenicline in its bulk and tablets

    Get PDF
    A simple, sensitive and accurate stability-indicating HPLC method has been developed and validated for determination of varenicline (VRC) in its bulk form and pharmaceutical tablets. Chromatographic separation was achieved on a Zorbax Eclipse XDB-C8 column (150 mm × 4.6 mm i.d., particle size 5 μm, maintained at ambient temperature) by a mobile phase consisted of acetonitrile and 50 mM potassium dihydrogen phosphate buffer (10:90, v/v) with apparent pH of 3.5 ± 0.1 and a flow rate of 1.0 ml/min. The detection wavelength was set at 235 nm. VRC was subjected to different accelerated stress conditions. The degradation products, when any, were well resolved from the pure drug with significantly different retention time values. The method was linear (r = 0.9998) at a concentration range of 2 - 14 μg/ml. The limit of detection and limit of quantitation were 0.38 and 1.11 μg/ml, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 2%. The accuracy of the method was proved; the mean recovery of VRC was 100.10 ± 1.08%. The proposed method has high throughput as the analysis involved short run-time (~ 6 min). The method met the ICH/FDA regulatory requirements. The proposed method was successfully applied for the determination of VRC in bulk and tablets with acceptable accuracy and precisions; the label claim percentages were 99.65 ± 0.32%. The results demonstrated that the method would have a great value when applied in quality control and stability studies for VRC

    Patients' preferences for subcutaneous trastuzumab versus conventional intravenous infusion for the adjuvant treatment of HER2-positive early breast cancer: final analysis of 488 patients in the international, randomized, two-cohort PrefHer study

    Get PDF
    BACKGROUND: Patients with HER2-positive early breast cancer (EBC) preferred subcutaneous (SC) trastuzumab, delivered via single-use injection device (SID), over the intravenous (IV) formulation (Cohort 1 of the PrefHer study: NCT01401166). Here we report patient preference, healthcare professional satisfaction, and safety data pooled from Cohort 1 and also Cohort 2, where SC trastuzumab was delivered via hand-held syringe. PATIENTS AND METHODS: Patients were randomized to receive 4 adjuvant cycles of 600 mg fixed-dose SC trastuzumab followed by 4 cycles of standard IV trastuzumab, or vice versa. The primary endpoint was overall preference proportions for SC or IV, assessed by patient interviews in the evaluable ITT population. RESULTS: A total of 245 patients were randomized to receive SC followed by IV and 243 received IV followed by SC (evaluable ITT populations: 235 and 232 patients, respectively). SC was preferred by 415/467 (88.9%; 95% CI, 85.7-91.6; P<.0001; two-sided test against null hypothesis of 65% SC preference); 45/467 preferred IV (9.6%; 7-13); 7/467 indicated no preference (1.5%; 1-3). Clinician-reported adverse events occurred in 292/479 (61.0%) and 245/478 (51.3%) patients during the pooled SC and IV periods, respectively (P<.05; 2x2 chi2); 16 patients (3.3%) in each period experienced grade 3 events; none were grade 4/5. CONCLUSION: PrefHer revealed compelling and consistent patient preferences for SC over IV trastuzumab, regardless of SID or hand-held syringe delivery. SC was well tolerated and safety was consistent with previous reports, including the HannaH study (NCT00950300). No new safety signals were identified compared to the known IV profile in EBC. PrefHer and HannaH confirm that SC trastuzumab is a validated and preferred option over IV for improving patients' care in HER2-positive breast cancer

    Pivotal Evaluation of the Accuracy of a Biomarker Used for Classification or Prediction: Standards for Study Design

    Get PDF
    Research methods for biomarker evaluation lag behind those for evaluating therapeutic treatments. Although a phased approach to development of biomarkers exists and guidelines are available for reporting study results, a coherent and comprehensive set of guidelines for study design has not been delineated. We describe a nested case–control study design that involves prospective collection of specimens before outcome ascertainment from a study cohort that is relevant to the clinical application. The biomarker is assayed in a blinded fashion on specimens from randomly selected case patients and control subjects in the study cohort. We separately describe aspects of the design that relate to the clinical context, biomarker performance criteria, the biomarker test, and study size. The design can be applied to studies of biomarkers intended for use in disease diagnosis, screening, or prognosis. Common biases that pervade the biomarker research literature would be eliminated if these rigorous standards were followed

    The IDvIP Trial: A two-centre randomised double-blind controlled trial comparing intramuscular diamorphine and intramuscular pethidine for labour analgesia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Intramuscular pethidine is routinely used throughout the UK for labour analgesia. Studies have suggested that pethidine provides little pain relief in labour and has a number of side effects affecting mother and neonate. It can cause nausea, vomiting and dysphoria in mothers and can cause reduced fetal heart rate variability and accelerations. Neonatal effects include respiratory depression and impaired feeding. There are few large studies comparing the relative side effects and efficacy of different opioids in labour. A small trial comparing intramuscular pethidine with diamorphine, showed diamorphine to have some benefits over pethidine when used for labour analgesia but the study did not investigate the adverse effects of either opioid.</p> <p>Methods</p> <p>The Intramuscular Diamorphine versus Intramuscular Pethidine (IDvIP) trial is a randomised double-blind two centre controlled trial comparing intramuscular diamorphine and pethidine regarding their analgesic efficacy in labour and their side effects in mother, fetus and neonate. Information about the trial will be provided to women in the antenatal period or in early labour. Consent and recruitment to the trial will be obtained when the mother requests opioid analgesia. The sample size requirement is 406 women with data on primary outcomes. The maternal primary outcomes are pain relief during the first 3 hours after trial analgesia and specifically pain relief after 60 minutes. The neonatal primary outcomes are need for resuscitation and Apgar Score <7 at 1 minute. The secondary outcomes are an additional measure of pain relief, maternal sedation, nausea and vomiting, maternal oxygen saturation, satisfaction with analgesia, whether method of analgesia would be used again, use of Entonox, umbilical arterial and venous pH, fetal heart rate, meconium staining, time from delivery to first breath, Apgar scores at 5 mins, naloxone requirement, transfer to neonatal intensive care unit, neonatal haemoglobin oxygen saturation at 30, 60, 90, and 120 mins after delivery, and neonatal sedation and feeding behaviour during first 2 hours.</p> <p>Discussion</p> <p>If the trial demonstrates that diamorphine provides better analgesia with fewer side effects in mother and neonate this could lead to a change in national practice and result in diamorphine becoming the preferred intramuscular opioid for analgesia in labour.</p> <p>Trial Registration</p> <p><a href="http://www.controlled-trials.com/ISRCTN14898678">ISRCTN14898678</a></p> <p>Eudra No: 2006-003250-18, REC Reference No: 06/Q1702/95, MHRA Authorisation No: 1443/0001/001-0001, NIHR UKCRN reference 6895, RfPB grant PB-PG-0407-13170_IR5</p

    Accounting for centre-effects in multicentre trials with a binary outcome - when, why, and how?

    Get PDF
    BACKGROUND: It is often desirable to account for centre-effects in the analysis of multicentre randomised trials, however it is unclear which analysis methods are best in trials with a binary outcome. METHODS: We compared the performance of four methods of analysis (fixed-effects models, random-effects models, generalised estimating equations (GEE), and Mantel-Haenszel) using a re-analysis of a previously reported randomised trial (MIST2) and a large simulation study. RESULTS: The re-analysis of MIST2 found that fixed-effects and Mantel-Haenszel led to many patients being dropped from the analysis due to over-stratification (up to 69% dropped for Mantel-Haenszel, and up to 33% dropped for fixed-effects). Conversely, random-effects and GEE included all patients in the analysis, however GEE did not reach convergence. Estimated treatment effects and p-values were highly variable across different analysis methods. The simulation study found that most methods of analysis performed well with a small number of centres. With a large number of centres, fixed-effects led to biased estimates and inflated type I error rates in many situations, and Mantel-Haenszel lost power compared to other analysis methods in some situations. Conversely, both random-effects and GEE gave nominal type I error rates and good power across all scenarios, and were usually as good as or better than either fixed-effects or Mantel-Haenszel. However, this was only true for GEEs with non-robust standard errors (SEs); using a robust ‘sandwich’ estimator led to inflated type I error rates across most scenarios. CONCLUSIONS: With a small number of centres, we recommend the use of fixed-effects, random-effects, or GEE with non-robust SEs. Random-effects and GEE with non-robust SEs should be used with a moderate or large number of centres

    Assaying Total Carotenoids in Flours of Corn and Sweetpotato by Laser Photoacoustic Spectroscopy

    Get PDF
    This study describes the application of the laser photoacoustic spectroscopy (PAS) for quantification of total carotenoids (TC) in corn flours and sweetpotato flours. Overall, thirty-three different corn flours and nine sweetpotato flours were investigated. All PAS measurements were performed at room temperature using 488-nm argon laser radiation for excitation and mechanical modulation of 9 and 30 Hz. The measurements were repeated within a run and within several days or months. The UV–Vis spectrophotometry was used as the reference method. The concentration range that allows for the reliable analysis of TC spans a region from 1 to 40 mg kg−1 for corn flours and from 9 to 40 mg kg−1 for sweetpotato flours. In the case of sweetpotato flours, the quantification may extend even to 240 mg kg−1 TC. The estimated detection limit values for TC in corn and sweetpotato flours were 0.1 and 0.3 mg kg−1, respectively. The computed repeatability (n = 3–12) and intermediate precision (n = 6–28) RSD values at 9 and 30 Hz are comparable: 0.1–17.1% and 5.3–14.7% for corn flours as compared with 1.4–9.1% and 4.2–23.0% for sweetpotato flours. Our results show that PAS can be successfully used as a new analytical tool to simply and rapidly screen the flours for their nutritional potential based on the total carotenoid concentration

    Development and validation of stability indicating method for determination of sertraline following ICH guidlines and its determination in pharmaceuticals and biological fluids

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sertraline is a well known antidepressant drug which belongs to a class called selective serotonin reuptake inhibitor. Most published methods do not enable studying the stability of this drug in different stress conditions.</p> <p>Results</p> <p>Two new methods were developed for the determination of sertraline (SER). Both methods are based on coupling with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in borate buffer of pH 7.8 and measuring the reaction product spectrophotometrically at 395 nm (Method I) or spectrofluorimetrically at 530 nm upon excitation at 480 nm (Method II). The response-concentration plots were rectilinear over the range 2-24 μg/mL and 0.25-5 μg/mL for methods I and II respectively with LOD of 0.18 μg/mL and 0.07 μg/mL, and LOQ of 0.56 μg/mL and 0.21 μg/mL for methods I and II, respectively.</p> <p>Conclusion</p> <p>Both methods were applied to the analysis of commercial tablets and the results were in good agreement with those obtained using a reference method. The fluorimetric method was further applied to the in vivo determination of SER in human plasma. A proposal of the reaction pathway was presented. The spectrophotometric method was extended to stability study of SER. The drug was exposed to alkaline, acidic, oxidative and photolytic degradation according to ICH guidelines. Moreover, the method was utilized to investigate the kinetics of oxidative degradation of the drug. The apparent first order rate constant and t<sub>1/2 </sub>of the degradation reaction were determined.</p

    3D inkjet printing of tablets exploiting bespoke complex geometries for controlled and tuneable drug release

    Get PDF
    A hot melt 3D inkjet printing method with the potential to manufacture formulations in complex and adaptable geometries for the controlled loading and release of medicines is presented. This first use of a precisely controlled solvent free inkjet printing to produce drug loaded solid dosage forms is demonstrated using a naturally derived FDA approved material (beeswax) as the drug carrier and fenofibrate as the drug. Tablets with bespoke geometries (honeycomb architecture) were fabricated. The honeycomb architecture was modified by control of the honeycomb cell size, and hence surface area to enable control of drug release profiles without the need to alter the formulation. Analysis of the formed tablets showed the drug to be evenly distributed within the beeswax at the bulk scale with evidence of some localization at the micron scale. An analytical model utilizing a Fickian description of diffusion was developed to allow the prediction of drug release. A comparison of experimental and predicted drug release data revealed that in addition to surface area, other factors such as the cell diameter in the case of the honeycomb geometry and material wettability must be considered in practical dosage form design. This information when combined with the range of achievable geometries could allow the bespoke production of optimized personalised medicines for a variety of delivery vehicles in addition to tablets, such as medical devices for example
    corecore