86 research outputs found

    Sub- and above barrier fusion of loosely bound 6^6Li with 28^{28}Si

    Full text link
    Fusion excitation functions are measured for the system 6^6Li+28^{28}Si using the characteristic γ\gamma-ray method, encompassing both the sub-barrier and above barrier regions, viz., ElabE_{lab}= 7-24 MeV. Two separate experiments were performed, one for the above barrier region (ElabE_{lab}= 11-24 MeV) and another for the below barrier region (ElabE_{lab}= 7-10 MeV). The results were compared with our previously measured fusion cross section for the 7^7Li+28^{28}Si system. We observed enhancement of fusion cross section at sub-barrier regions for both 6^6Li and 7^7Li, but yield was substantially larger for 6^6Li. However, for well above barrier regions, similar type of suppression was identified for both the systems.Comment: 8 pages, 6 figures, as accepted for publication in Eur.Phys.J.

    Microscopic model analyses of proton scattering from 12C, 20Ne, 24Mg, 28Si and 40Ca

    Full text link
    Differential cross sections and analyzing powers for elastic scattering from, and for inelastic proton scattering to a set of 21+2^+_1 states in, 12{}^{12}C, 20{}^{20}Ne, 24{}^{24}Mg, 28{}^{28}Si and 40{}^{40}Ca, and for a set of energies between 35 to 250 MeV, have been analyzed. A gg-folding model has been used to determine optical potentials and a microscopic distorted wave approximation taken to analyze the inelastic data. The effective nucleon-nucleon interactions used to specify the optical potentials have also been used as the transition operators in the inelastic scattering processes. Shell and large space Hartree-Fock models of structure have been used to describe the nuclear states.Comment: 27 pages, 18 figure

    Quantum cascade laser frequency stabilisation at the sub-Hz level

    Full text link
    Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species

    Quantum cascade laser based hybrid dual comb spectrometer

    Get PDF
    Four-wave-mixing-based quantum cascade laser frequency combs (QCL-FC) are a powerful photonic tool, driving a recent revolution in major molecular fingerprint regions, i.e. mid- and far-infrared domains. Their compact and frequency-agile design, together with their high optical power and spectral purity, promise to deliver an all-in-one source for the most challenging spectroscopic applications. Here, we demonstrate a metrological-grade hybrid dual comb spectrometer, combining the advantages of a THz QCL-FC with the accuracy and absolute frequency referencing provided by a free-standing, optically-rectified THz frequency comb. A proof-of-principle application to methanol molecular transitions is presented. The multi-heterodyne molecular spectra retrieved provide state-of-the-art results in line-center determination, achieving the same precision as currently available molecular databases. The devised setup provides a solid platform for a new generation of THz spectrometers, paving the way to more refined and sophisticated systems exploiting full phase control of QCL-FCs, or Doppler-free spectroscopic schemes

    Fully Phase Stabilized Quantum Cascade Laser Frequency Comb

    Get PDF
    The road towards the realization of quantum cascade laser (QCL) frequency combs [1,2] has undoubtedly attracted ubiquitous attention from the scientific community. These devices promise to deliver an all-in-one (i.e. a single, miniature, active device) frequency comb synthesizer in a range as wide as the QCL spectral coverage itself (from about 4 microns to the THz range), with the unique possibility to tailor their spectral emission by band structure engineering. For these reasons, vigorous efforts have been spent to characterize the emission of four-wave-mixing (FWM) multi-frequency QCLs, aiming to seize their comb-like mode-locked operation [3–6]

    Laser spectroscopy for breath analysis : towards clinical implementation

    Get PDF
    Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays. This review presents an update of the current status of optical methods, using near and mid-infrared sources, for clinical breath gas analysis over the last decade and describes recent technological developments and their applications. The review includes: tunable diode laser absorption spectroscopy, cavity ring-down spectroscopy, integrated cavity output spectroscopy, cavity-enhanced absorption spectroscopy, photoacoustic spectroscopy, quartz-enhanced photoacoustic spectroscopy, and optical frequency comb spectroscopy. A SWOT analysis (strengths, weaknesses, opportunities, and threats) is presented that describes the laser-based techniques within the clinical framework of breath research and their appealing features for clinical use.Peer reviewe
    corecore