769 research outputs found

    Amino acids in samples of surface sea water

    Get PDF
    Both paper and ion exchange chromatographic techniques have been used to identify and make a partial quantitative estimate of amino acids in surface water samples collected in four subtropical regions. The most abundant of the 18 amino acids identified were aspartic acid, threonine, serine, glutamic acid, alanine, valine, isoleucine, and leucine. In general, basic amino acids, possibly except for lysine, seem to be in low concentration. The amino acid composition of hydrolysates of proteinaceous material in sea water varies in the samples. These differences may be important in the ecology of marine organisms

    A cross sectional study of water quality from dental unit water lines in dental practices in the West of Scotland

    Get PDF
    OBJECTIVE: To determine the microbiological quality of water from dental units in a general practice setting and current practice for disinfection of units. DESIGN: A cross-sectional study of the water quality from 40 dental units in 39 general practices and a questionnaire of the disinfection protocols used in those practices. SETTING: NHS practices in primarydental care. SUBJECTS: Thirty-nine general practices from the West of Scotland. METHODS: Water samples were collected on two separate occasions from dental units and analysed for microbiological quality by the total viable count (TVC) method. Water specimens were collected from the triple syringe, high speed outlet, cup filler and surgery tap. Each participating practitioner was asked to complete a questionnaire. Results Microbial contamination was highest from the high speed outlet followed by the triple syringe and cup filler. On average, the TVC counts from the high speed water lines at 37 degrees C and for the high speed lines, triple syringe and cup filler at 22 degrees C were significantly higher than that from the control tap water specimens. The study included units from 11 different manufacturers with ages ranging from under one year to over eight years. The age of the dental unit analysed did not appear to influence the level of microbial contamination. Five of the practices surveyed used disinfectants to clean the dental units but these had no significant effect on the microbiological quality of the water. The majority of dental units (25 out of 40) were never flushed with water between patients. A number of different non-sterile irrigants were used for surgical procedures. CONCLUSION: The microbiological quality of water from dental units in general dental practice is poor compared with that from drinking water sources. Suitable sterile irrigants should be used for surgical procedures in dental practice. Further work is required for pragmatic decontamination regimens of dental unit water lines in a general dental practice setting

    Evaluation of the efficacy of Alpron disinfectant for dental unit water lines

    Get PDF
    AIMS: To assess the efficacy of a disinfectant, Alpron, for controlling microbial contamination within dental unit water lines. METHODS: The microbiological quality of water emerging from the triple syringe, high speed handpiece, cup filler and surgery hand wash basin from six dental units was assessed for microbiological total viable counts at 22 degrees C and 37 degrees C before and after treatment with Alpron solutions. RESULTS: The study found that the use of Alpron disinfectant solutions could reduce microbial counts in dental unit water lines to similar levels for drinking water. This effect was maintained in all units for up to six weeks following one course of treatment. In four out of six units the low microbial counts were maintained for 13 weeks. CONCLUSIONS: Disinfectants may have a short term role to play in controlling microbial contamination of dental unit water lines to drinking water quality. However, in the longer term attention must be paid to redesigning dental units to discourage the build up of microbial biofilms

    Kinematics and helicity evolution of a loop-like eruptive prominence

    Full text link
    We aim at investigating the morphology, kinematic and helicity evolution of a loop-like prominence during its eruption. We use multi-instrument observations from AIA/SDO, EUVI/STEREO and LASCO/SoHO. The kinematic, morphological, geometrical, and helicity evolution of a loop-like eruptive prominence are studied in the context of the magnetic flux rope model of solar prominences. The prominence eruption evolved as a height expanding twisted loop with both legs anchored in the chromosphere of a plage area. The eruption process consists of a prominence activation, acceleration, and a phase of constant velocity. The prominence body was composed of left-hand (counter-clockwise) twisted threads around the main prominence axis. The twist during the eruption was estimated at 6pi (3 turns). The prominence reached a maximum height of 526 Mm before contracting to its primary location and partially reformed in the same place two days after the eruption. This ejection, however, triggered a CME seen in LASCO C2. The prominence was located in the northern periphery of the CME magnetic field configuration and, therefore, the background magnetic field was asymmetric with respect to the filament position. The physical conditions of the falling plasma blobs were analysed with respect to the prominence kinematics. The same sign of the prominence body twist and writhe, as well as the amount of twisting above the critical value of 2pi after the activation phase indicate that possibly conditions for kink instability were present. No signature of magnetic reconnection was observed anywhere in the prominence body and its surroundings. The filament/prominence descent following the eruption and its partial reformation at the same place two days later suggest a confined type of eruption. The asymmetric background magnetic field possibly played an important role in the failed eruption.Comment: 9 pages, 8 figures, in press in A&

    Patient-reported measurement of time to diagnosis in cancer: development of the Cancer Symptom Interval Measure (C-SIM) and randomised controlled trial of method of delivery

    Get PDF
    Background: The duration between first symptom and a cancer diagnosis is important because, if shortened, may lead to earlier stage diagnosis and improved cancer outcomes. We have previously developed a tool to measure this duration in newly-diagnosed patients. In this two-phase study, we aimed further improve our tool and to conduct a trial comparing levels of anxiety between two modes of delivery: self-completed versus researcher-administered. Methods: In phase 1, ten patients completed the modified tool and participated in cognitive debrief interviews. In phase 2, we undertook a Randomised Controlled Trial (RCT) of the revised tool (Cancer Symptom Interval Measure (C-SIM)) in three hospitals for 11 different cancers. Respondents were invited to provide either exact or estimated dates of first noticing symptoms and presenting them to primary care. The primary outcome was anxiety related to delivery mode, with completeness of recording as a secondary outcome. Dates from a subset of patients were compared with GP records. Results: After analysis of phase 1 interviews, the wording and format were improved. In phase 2, 201 patients were randomised (93 self-complete and 108 researcher-complete). Anxiety scores were significantly lower in the researcher-completed group, with a mean rank of 83.5; compared with the self-completed group, with a mean rank of 104.0 (Mann-Whitney U = 3152, p = 0.007). Completeness of data was significantly better in the researcher-completed group, with no statistically significant difference in time taken to complete the tool between the two groups. When comparing the dates in the patient questionnaires with those in the GP records, there was evidence in the records of a consultation on the same date or within a proscribed time window for 32/37 (86%) consultations; for estimated dates there was evidence for 23/37 consultations (62%). Conclusions: We have developed and tested a tool for collecting patient-reported data relating to appraisal intervals, help-seeking intervals, and diagnostic intervals in the cancer diagnostic pathway for 11 separate cancers, and provided evidence of its acceptability, feasibility and validity. This is a useful tool to use in descriptive and epidemiological studies of cancer diagnostic journeys, and causes less anxiety if administered by a researcher

    Measurements of Differential Reflectivity in Snowstorms and Warm Season Stratiform Systems

    Get PDF
    The organized behavior of differential radar reflectivity (ZDR) is documented in the cold regions of a wide variety of stratiform precipitation types occurring in both winter and summer. The radar targets and attendant cloud microphysical conditions are interpreted within the context of measurements of ice crystal types in laboratory diffusion chambers in which humidity and temperature are both stringently controlled. The overriding operational interest here is in the identification of regions prone to icing hazards with long horizontal paths. Two predominant regimes are identified: category A, which is typified by moderate reflectivity (from 10 to 30 dBZ) and modest +ZDR values (from 0 to +3 dB) in which both supercooled water and dendritic ice crystals (and oriented aggregates of ice crystals) are present at a mean temperature of −13°C, and category B, which is typified by small reflectivity (from −10 to +10 dBZ) and the largest +ZDR values (from +3 to +7 dB), in which supercooled water is dilute or absent and both flat-plate and dendritic crystals are likely. The predominant positive values for ZDR in many case studies suggest that the role of an electric field on ice particle orientation is small in comparison with gravity. The absence of robust +ZDR signatures in the trailing stratiform regions of vigorous summer squall lines may be due both to the infusion of noncrystalline ice particles (i.e., graupel and rimed aggregates) from the leading deep convection and to the effects of the stronger electric fields expected in these situations. These polarimetric measurements and their interpretations underscore the need for the accurate calibration of ZDR.United States. Federal Aviation Administration (Air Force Contract FA8721-05-C-0002

    Fifteen years of clinical liver transplantation

    Get PDF
    Liver transplantation in humans was first attempted more than 15 yr ago. The 1-yr survival has slowly improved until it has now reached about 50%. In our experience, 46 patients have lived for at least 1 yr, with the longest survival being 9 yr. The high acute mortality in early trials was due in many cases to technical and management errors and to the use of damaged organs. With elimination of such factors, survival increased. Further improvements will depend upon better immunosuppression. Orthotopic liver transplantation (liver replacement) is the preferred operation in most cases, but placement of an extra liver (auxiliary transplantation) may have a role under special circumstances. © 1979
    • …
    corecore