54 research outputs found

    Reproductive Intentions and Outcomes among Women on Antiretroviral Therapy in Rural Uganda: A Prospective Cohort Study

    Get PDF
    Background: Antiretroviral therapy (ART) may influence the biological, social and behavioral determinants of pregnancy in HIV-infected women. However, there are limited longitudinal data on the reproductive intentions and outcomes among women on ART in Africa. Methodology /Principal Findings: Using a prospective cohort design, we analyzed trends in desire for children and predictors of pregnancy among a cohort of 733 HIV-infected women in rural Uganda who initiated ART between May 2003 and May 2004 and were followed up in their homes until June 2006. Women answered in-depth social and behavioral questionnaires administered every quarter in year 1 after initiating ART, and every 6 to 12 months thereafter. Use of family planning methods was assessed at 18 and 24 months after starting ART. We tested for non-constant pregnancy incidence by using a shape parameter test from the Weibull distribution. We modeled repeated measurements of all variables related to the women’s desire for children over time using a generalized estimating equation (GEE) extension to the logistic regression model. Risk factors for pregnancy were examined using Cox proportional hazards model. 711 women eligible for the study were followed-up for a median time of 2.4 years after starting ART. During this time, less than 7 % of women reported wanting more children at any time point yet 120 (16.9%) women experienced 140 pregnancies and pregnancy incidence increased from 3.46 per 100 women-years (WY) in the first quarter to 9.5 per 100 WY at 24 months (p,0.0001). This wa

    SHANK3 conformation regulates direct actin binding and crosstalk with Rap1 signaling

    Get PDF
    Actin-rich cellular protrusions direct versatile biological processes from cancer cell invasion to dendritic spine development. The stability, morphology, and specific biological functions of these protrusions are regulated by crosstalk between three main signaling axes: integrins, actin regulators, and small guanosine triphosphatases (GTPases). SHANK3 is a multifunctional scaffold protein, interacting with several actin-binding proteins and a well-established autism risk gene. Recently, SHANK3 was demonstrated to sequester integrin-activating small GTPases Rap1 and R-Ras to inhibit integrin activity via its Shank/ProSAP N-terminal (SPN) domain. Here, we demonstrate that, in addition to scaffolding actin regulators and actin-binding proteins, SHANK3 interacts directly with actin through its SPN domain. Molecular simulations and targeted mutagenesis of the SPN-ankyrin repeat region (ARR) interface reveal that actin binding is inhibited by an intramolecular closed conformation of SHANK3, where the adjacent ARR domain covers the actin-binding interface of the SPN domain. Actin and Rap1 compete with each other for binding to SHANK3, and mutation of SHANK3, resulting in reduced actin binding, augments inhibition of Rap1-mediated integrin activity. This dynamic crosstalk has functional implications for cell morphology and integrin activity in cancer cells. In addition, SHANK3-actin interaction regulates dendritic spine morphology in neurons and autism-linked phenotypes in vivo

    Balancing collective responsibility, individual opportunities and risks: a qualitative study on how police officers reason around volunteering in an HIV vaccine trial in Dar es Salaam, Tanzania

    Get PDF
    Results from HIV vaccine trials on potential volunteers will contribute to global efforts to develop an HIV vaccine. The purpose of this study among police officers in Dar es Salaam, Tanzania, was to explore the underlying reasons that induce people to enrol in an HIV vaccine trial.\ud We conducted discussions with eight focus groups, containing a total of 66 police officers. The information collected was analyzed using interpretive description. The results showed that participants were motivated to participate in the trial by altruism, and that the participants experienced some concerns about their participation. They stated that altruism in the fight against HIV infection was the main reason for enrolling in the trial. However, young participants were seriously concerned about a possible loss of close relationships if they enrolled in the HIV vaccine trial. Both men and women feared the effect of the trial on their reproductive biology, and they feared interference with pregnancy norms. They were unsure about risks such as the risks of acquiring HIV infection and of suffering physical harm, and they were unsure of the intentions of the researchers conducting the trial. Further, enrolling in the trial required medical examination, and this led some participants to fear that unknown diseases would be revealed. Other participants, however, saw an opportunity to obtain free health services.\ud We have shown that specific fears are important concerns when recruiting volunteers to an HIV vaccine trial. More knowledge is needed to determine participants' views and to ensure that they understand the conduct of the trial and the reasons it is being carried out

    Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

    Get PDF
    The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam

    Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

    Get PDF
    During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m2^{2} of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 1015^{15} neq_{eq}/cm2^{2}. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker

    Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

    Get PDF
    The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip

    Pragmatic markers in Hungarian: Some introductory remarks

    Full text link

    Prospective observational cohort study of the association between antiplatelet therapy, bleeding and thrombosis in patients with coronary stents undergoing noncardiac surgery

    Get PDF
    Background: The perioperative management of antiplatelet therapy in noncardiac surgery patients who have undergone previous percutaneous coronary intervention (PCI) remains a dilemma. Continuing dual antiplatelet therapy (DAPT) may carry a risk of bleeding, while stopping antiplatelet therapy may increase the risk of perioperative major adverse cardiovascular events (MACE). Methods: Occurrence of Bleeding and Thrombosis during Antiplatelet Therapy In Non-Cardiac Surgery (OBTAIN) was an international prospective multicentre cohort study of perioperative antiplatelet treatment, MACE, and serious bleeding in noncardiac surgery. The incidences of MACE and bleeding were compared in patients receiving DAPT, monotherapy, and no antiplatelet therapy before surgery. Unadjusted risk ratios were calculated taking monotherapy as the baseline. The adjusted risks of bleeding and MACE were compared in patients receiving monotherapy and DAPT using propensity score matching. Results: A total of 917 patients were recruited and 847 were eligible for inclusion. Ninety-six patients received no antiplatelet therapy, 526 received monotherapy with aspirin, and 225 received DAPT. Thirty-two patients suffered MACE and 22 had bleeding. The unadjusted risk ratio for MACE in patients receiving DAPT compared with monotherapy was 1.9 (0.93–3.88), P=0.08. There was no difference in MACE between no antiplatelet treatment and monotherapy 1.03 (0.31–3.46), P=0.96. Bleeding was more frequent with DAPT 6.55 (2.3–17.96) P=0.0002. In a propensity matched analysis of 177 patients who received DAPT and 177 monotherapy patients, the risk ratio for MACE with DAPT was 1.83 (0.69–4.85), P=0.32. The risk of bleeding was significantly greater in the DAPT group 4.00 (1.15–13.93), P=0.031. Conclusions: OBTAIN showed an increased risk of bleeding with DAPT and found no evidence for protective effects of DAPT from perioperative MACE in patients who have undergone previous PCI
    corecore