328 research outputs found

    "Smoking gun" signatures of topological milestones in trivial materials by measurement fine-tuning and data postselection

    Full text link
    Exploring the topology of electronic bands is a way to realize new states of matter with possible implications for information technology. Because bands cannot always be observed directly, a central question is how to tell that a topological regime has been achieved. Experiments are often guided by a prediction of a unique signal or a pattern, called "the smoking gun". Examples include peaks in conductivity, microwave resonances, and shifts in interference fringes. However, many condensed matter experiments are performed on relatively small, micron or nanometer-scale, specimens. These structures are in the so-called mesoscopic regime, between atomic and macroscopic physics, where phenomenology is particularly rich. In this paper, we demonstrate that the trivial effects of quantum confinement, quantum interference and charge dynamics in nanostructures can reproduce accepted smoking gun signatures of triplet supercurrents, Majorana modes, topological Josephson junctions and fractionalized particles. The examples we use correspond to milestones of topological quantum computing: qubit spectroscopy, fusion and braiding. None of the samples we use are in the topological regime. The smoking gun patterns are achieved by fine-tuning during data acquisition and by subsequent data selection to pick non-representative examples out of a fluid multitude of similar patterns that do not generally fit the "smoking gun" designation. Building on this insight, we discuss ways that experimentalists can rigorously delineate between topological and non-topological effects, and the effects of fine-tuning by deeper analysis of larger volumes of data.Comment: Data are available through Zenodo at DOI: 10.5281/zenodo.834930

    Radiomics-Based Assessment of Primary Sjögren's Syndrome From Salivary Gland Ultrasonography Images

    Get PDF
    Salivary gland ultrasonography (SGUS) has shown good potential in the diagnosis of primary Sjögren's syndrome (pSS). However, a series of international studies have reported needs for improvements of the existing pSS scoring procedures in terms of inter/intra observer reliability before being established as standardized diagnostic tools. The present study aims to solve this problem by employing radiomics features and artificial intelligence (AI) algorithms to make the pSS scoring more objective and faster compared to human expert scoring. The assessment of AI algorithms was performed on a two-centric cohort, which included 600 SGUS images (150 patients) annotated using the original SGUS scoring system proposed in 1992 for pSS. For each image, we extracted 907 histogram-based and descriptive statistics features from segmented salivary glands. Optimal feature subsets were found using the genetic algorithm based wrapper approach. Among the considered algorithms (seven classifiers and five regressors), the best preforming was the multilayer perceptron (MLP) classifier (κ = 0.7). The MLP over-performed average score achieved by the clinicians (κ = 0.67) by the considerable margin, whereas its reliability was on the level of human intra-observer variability (κ = 0.71). The presented findings indicate that the continuously increasing HarmonicSS cohort will enable further advancements in AI-based pSS scoring methods by SGUS. In turn, this may establish SGUS as an effective noninvasive pSS diagnostic tool, with the final goal to supplement current diagnostic tests

    Unintentional high density p-type modulation doping of a GaAs/AlAs core-multi-shell nanowire

    Get PDF
    Achieving significant doping in GaAs/AlAs core/shell nanowires (NWs) is of considerable technological importance but remains a challenge due to the amphoteric behavior of the dopant atoms. Here we show that placing a narrow GaAs quantum well in the AlAs shell effectively getters residual carbon acceptors leading to an \emph{unintentional} p-type doping. Magneto-optical studies of such a GaAs/AlAs core multi-shell NW reveal quantum confined emission. Theoretical calculations of NW electronic structure confirm quantum confinement of carriers at the core/shell interface due to the presence of ionized carbon acceptors in the 1~nm GaAs layer in the shell. Micro-photoluminescence in high magnetic field shows a clear signature of avoided crossings of the n=0n=0 Landau level emission line with the n=2n=2 Landau level TO phonon replica. The coupling is caused by the resonant hole-phonon interaction, which points to a large 2D hole density in the structure.Comment: just published in Nano Letters (http://pubs.acs.org/doi/full/10.1021/nl500818k

    Planar Josephson Junctions Templated by Nanowire Shadowing

    Full text link
    More and more materials, with a growing variety of properties, are built into electronic devices. This is motivated both by increased device performance and by the studies of materials themselves. An important type of device is a Josephson junction based on the proximity effect between a quantum material and a superconductor, useful for fundamental research as well as for quantum and other technologies. When both junction contacts are placed on the same surface, such as a two-dimensional material, the junction is called ``planar". One outstanding challenge is that not all materials are amenable to the standard planar junction fabrication. The device quality, rather than the intrinsic characteristics, may be defining the results. Here, we introduce a technique in which nanowires are placed on the surface and act as a shadow mask for the superconductor. The advantages are that the smallest dimension is determined by the nanowire diameter and does not require lithography, and that the junction is not exposed to chemicals such as etchants. We demonstrate this method with an InAs quantum well, using two superconductors - Al and Sn, and two semiconductor nanowires - InAs and InSb. The junctions exhibit critical current levels consistent with transparent interfaces and uniform width. We show that the template nanowire can be operated as a self-aligned electrostatic gate. Beyond single junctions, we create SQUIDs with two gate-tunable junctions. We suggest that our method can be used for a large variety of quantum materials including van der Waals layers, topological insulators, Weyl semimetals and future materials for which proximity effect devices is a promising research avenue.Comment: Written using The Block Method. Data on Zenodo DOI: https://doi.org/10.5281/zenodo.641608

    Role of serum S100B and PET-CT in follow-up of patients with cutaneous melanoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Increased level of serum S100B can serve as a marker of metastatic spread in patients with cutaneous melanoma (CM). In patients with elevated S100 B and/or clinical signs of disease progression PET-CT scan is a valuable tool for discovering metastases and planning treatment.</p> <p>The aims of this study were to determine whether regular measurements of serum S100B are a useful tool for discovering patients with CM metastases and to evaluate the diagnostic value of PET-CT during the follow-up.</p> <p>Methods</p> <p>From September 2007 to February 2010, 115 CM patients included in regular follow up at the Institute of Oncology Ljubljana were appointed to PET-CT. There were 82 (71.3%) patients with clinical signs of disease progression and 33 (28.7%) asymptomatic patients with two subsequent elevated values of S100B. Sensitivity, specificity, positive and negative predictive value (PPV, NPV) of S100B and PET-CT were calculated using standard procedures.</p> <p>Results</p> <p>Disease progression was confirmed in 81.7% of patients (in 86.5% of patients with clinical signs of disease progression and in 69.7% of asymptomatic patients with elevated S100B). Sensitivity, specificity, PPV and NPV of S100B was 33.8%, 90.9%, 96.0% and 17.5% in patients with clinical signs of disease progression. In 20.0% of patients increased serum S100B was the only sign of disease progression. Sensitivity and PPV of S100 in this group of patients were 100.0% and 69.7%.</p> <p>With PET-CT disease progression was diagnosed in 84.2% of symptomatic patients and in 72.7% of asymptomatic patients with elevated S100B. The sensitivity, specificity, PPV and NPV of PET-CT for symptomatic patients was 98.5%, 90.9%, 98.5% and 90.9% and 100%, 90.0%, 95.8% and 100% for asymptomatic patients with elevated S100.</p> <p>Conclusions</p> <p>Measurements of serum S100B during regular follow-up of patients with CM are a useful tool for discovering disease progression in asymptomatic patients. The value of its use increases if measurements are followed by extended whole body PET-CT.</p

    Generic nano-imprint process for fabrication of nanowire arrays

    Full text link
    A generic process has been developed to grow nearly defect free arrays of (heterostructured) InP and GaP nanowires. Soft nanoimprint lithography has been used to pattern gold particle arrays on full 2 inch substrates. After lift-off organic residues remain on the surface, which induce the growth of additional undesired nanowires. We show that cleaning of the samples before growth with piranha solution in combination with a thermal anneal at 550 C for InP and 700 C for GaP results in uniform nanowire arrays with 1% variation in nanowire length, and without undesired extra nanowires. Our chemical cleaning procedure is applicable to other lithographic techniques such as e-beam lithography, and therefore represents a generic process.Comment: 12 pages, 4 figures, 2 table
    corecore