35 research outputs found

    Intra- and inter-brand color differences of denture teeth under different illuminations

    Get PDF
    Debonding, staining and wear are usually the reasons for denture teeth replacement by new ones from same or different brands. Objective: This study investigates the possible differences in color of denture teeth of the same or different brands under different illuminations, since their metameric behavior in color under specific illumination may become unacceptable. Methodology: For the purpose of this study, 10 denture teeth (#11), shade A3, of 4 different brands were selected (Creopal/KlemaDental Pro, Executive/DeguDent, Cosmo HXL/DeguDent, Ivostar/Ivoclar-Vivadent). Teeth stabilized in white silicone mold and the CIELAB color coordinates of their labial surface under 3 different illumination lights (D65, F2, A) were recorded, using a portable colorimeter (FRU/WR-18, Wave Inc). ΔE*ab values of all possible pairs of teeth of the same brand (n=45) or pair combinations of different brands (n=100) under each illumination light, in a dry and wet state were calculated. Data were analyzed statistically using 3-way ANOVA, Friedman’s and Wilcoxon’s tests at a significance level of α=0.05. Results: The results showed that brand type affected significantly L*, a* and b* coordinates (p<0.0001), illumination a* and b* coordinates (p<0.0001), but none of them was affected by the hydration state of teeth (p>0.05). Intra-brand color differences ranged between 0.21-0.78ΔΕ* units with significant differences among brands (p<0.0001), among illumination lights (p<0.0001) and between hydration states (p=0.0001). Inter-brand differences ranged between 2.29-6.29ΔΕ* units with significant differences among pairs of brands (p<0.0001), illumination lights (p<0.0001) and hydration states (p<0.0001). Conclusions: Differences were found between and within brands under D65 illumination which increased under F2 or A illumination affected by brand type and hydration status. Executive was the most stable brand than the others under different illuminations or wet states and for this reason its difference from other brands is the lowest. In clinical practice, there should be no blending of teeth of different brands but if we must, we should select those that are more stable under different illuminations

    Long-term microwaving of denture base materials: effects on dimensional, color and translucency stability

    Get PDF
    While the combined effect of microwave irradiation with cleansing solutions on denture base materials has been investigated, the effects of only using microwave irradiation and, more importantly, in a long-term basis, was not studied yet. Objective: The purpose of this study was to evaluate the effect of a long-term repeated microwaving on the dimensional, color and translucency stability of acrylic and polyamide denture base materials. Material and Methods: Thirty two specimens (32 mm x 10 mm x 2.5 mm) from polyamide (Valplast) and PMMA (Vertex Rapid Simplified) denture base materials were made. Eight specimens from each material were immersed in distilled water (control) and 8 were subjected to microwave exposure at 450 W for 3 minutes for a period simulating 224 days of daily disinfection. Linear dimension, color change (ΔE*) and translucency parameter (TP) were measured at baseline and after certain intervals up to 224 cycles of immersion, using a digital calliper and a portable colorimeter. The results were analysed using two-way repeated measures ANOVA to estimate possible differences among predetermined cycles and material type. Regression analysis was also performed to estimate the trend of changes with time. Statistical evaluations performed at a significance level of 5%. Results: Data analysis showed significant changes in length at baseline with an increasing number of cycles (p<0.05) and a significant interaction of cycle-material (p<0.001). The ΔΕ* parameter was significantly higher with a higher number of cycles (p<0.001), but it did not vary between materials (p>0.05). TP decreased similarly in both materials following microwave action but in a significantly higher level for Valplast (p<0.001). Conclusions: The results indicated that long-term repeated microwaving affects linear dimensional, color and translucency changes of both materials. Differences between PMMA and polyamide material were noted only in dimension and translucency changes

    Diversity of site-specific microbes of occlusal and proximal lesions in severe- early childhood caries (S-ECC)

    Get PDF
    Background: Severe-early childhood caries (S-ECC) a global problem of significant concern, commonly manifest on the occlusal, and proximal surfaces of affected teeth. Despite the major ecological differences between these two niches the compositional differences, if any, in the microbiota of such lesions is unknown. Methods: Deep-dentine caries samples from asymptomatic primary molars of children with S-ECC (n 19) belonging to caries-code 5/6, (ICDAS classification) were evaluated. Employing two primer pools, we amplified and compared the bacterial 16S rRNA gene sequences of the seven hypervariable regions (V2—V4 and V6—V9) using NGS-based assay. Results: Bray-Curtisevaluation indicated that occlusal lesions (OL) had a more homogeneous community than the proximal lesions (PL) with significant compositional differences at the species level (p = 0.01; R- 0.513). Together, the occlusal and proximal niches harbored 263 species, of which 202 (76.8%) species were common to both, while 49 (18.6%) and 12 (4.6%) disparate species were exclusively isolated from the proximal and occlusal niches, respectively. The most commonl genera at both niches included Streptococcus, Prevotella, and Lactobacillus. S. mutans was predominant in PL (p ≤ 0.05), and Atopobium parvulum (p = 0.01) was predominant in OL. Conclusions: Distinct differences exist between the caries microbiota of occlusal and proximal caries in S-ECC

    Natural and recombinant equine chorionic gonadotropins past and future in animal reproductive technology

    Get PDF
    Equine Chorionic Gonadotropin (eCG) previously named Pregnant Mare Serum Gonadotropin (PMSG) has been widely used since the 40s in animal reproduction control. It is extracted from the blood of pregnant mares between days 40 and 120 of gestation. Animal welfare organizations have voiced concerns against mares bleeding conditions. There is currently no effective substitute for the natural PMSG. In this review, we summarize the basic knowledge of the structure and biology of eCG, and the research on recombinant eCG production in the past five years

    Meningitis patients with Angiostrongylus cantonensis may present without eosinophilia in the cerebrospinal fluid in northern Vietnam.

    Get PDF
    BACKGROUND: Eosinophilic meningitis (EM) is a rare clinical syndrome caused by both infectious and noninfectious diseases. In tropical pacific countries, Angiostrongylus cantonensis is the most common cause. However, the EM definition varies in the literature, and its relation to parasitic meningitis (PM) remains unclear. METHODOLOGY/PRINCIPAL FINDINGS: Adult and adolescent patients of 13 years old or above with suspected central nervous system (CNS) infections with abnormal CSF findings were prospectively enrolled at a tertiary referral hospital in Hanoi, Vietnam from June 2012 to May 2014. Patients with EM or suspected PM (EM/PM) were defined by the presence of either ≥10% eosinophils or an absolute eosinophil cell counts of ≥10/mm3 in the CSF or blood eosinophilia (>16% of WBCs) without CSF eosinophils. In total 679 patients were enrolled: 7 (1.03%) had ≥10% CSF eosinophilia, 20 (2.95%) had ≥10/mm3 CSF eosinophilia, and 7 (1.03%) had >16% blood eosinophilia. The patients with ≥10% CSF eosinophilia were significantly younger (p = 0.017), had a lower body temperature (p = 0.036) than patients with ≥10/mm3 CSF eosinophilia among whom bacterial pathogens were detected in 72.2% (13/18) of those who were tested by culture and/or PCR. In contrast, the characteristics of the patients with >16% blood eosinophilia resembled those of patients with ≥10% CSF eosinophilia. We further conducted serological tests and real-time PCR to identify A. cantonensis. Serology or real-time PCR was positive in 3 (42.8%) patients with ≥10% CSF eosinophilia and 6 (85.7%) patients with >16% blood eosinophilia without CSF eosinophils but none of patients with ≥10/mm3 CSF eosinophilia. CONCLUSIONS: The etiology of PM in northern Vietnam is A. cantonensis. The eosinophil percentage is a more reliable predictor of parasitic EM than absolute eosinophil count in the CSF. Patients with PM may present with a high percentage of eosinophils in the peripheral blood but not in the CSF

    Challenges in diagnosing scrub typhus among hospitalized patients with undifferentiated fever at a national tertiary hospital in northern Vietnam

    Get PDF
    BACKGROUND: Scrub typhus (ST) is a leading cause of non-malarial febrile illness in Southeast Asia, but evidence of its true disease burden is limited because of difficulties of making the clinical diagnosis and lack of adequate diagnostic tests. To describe the epidemiology and clinical characteristics of ST, we conducted an observational study using multiple diagnostic assays at a national tertiary hospital in Hanoi, Vietnam. METHODOLOGY/PRINCIPAL FINDINGS: We enrolled 1,127 patients hospitalized with documented fever between June 2012 and May 2013. Overall, 33 (2.9%) patients were diagnosed with ST by PCR and/or screening of ELISA for immunoglobulin M (IgM) with confirmatory tests: 14 (42.4%) were confirmed by indirect immunoperoxidase assay (IIP), and 19 (57.6%) were by IIP and PCR. Living by farming, conjunctival injection, eschar, aspartate aminotransferase elevation, and alanine aminotransferase elevation were significantly associated with ST cases (adjusted odds ratios (aORs): 2.8, 3.07, 48.8, 3.51, and 4.13, respectively), and having a comorbidity and neutrophilia were significantly less common in ST cases (aORs: 0.29 and 0.27, respectively). The majority of the ST cases were not clinically diagnosed with rickettsiosis (72.7%). Dominant IIP reactions against a single antigen were identified in 15 ST cases, whereas indistinguishably high reactions against multiple antigens were seen in 11 ST cases. The most frequently observed dominant IIP reaction was against Karp antigen (eight cases) followed by Gilliam (four cases). The highest diagnostic accuracy of IgM ELISA in acute samples was 78%. In a phylogenetic analysis of the 56-kDa type-specific antigen gene, the majority (14 cases) were located in the Karp-related branch followed by the Gilliam-related (two cases), Kato-related (two cases), and TA763-related clades (one case). CONCLUSIONS/SIGNIFICANCE: Both the clinical and laboratory diagnoses of ST remain challenging at a tertiary hospital. Implementation of both serological and nucleic acid amplification assays covering endemic O. tsutsugamushi strains is essential

    The baseline characteristics and interim analyses of the high-risk sentinel cohort of the Vietnam Initiative on Zoonotic InfectiONS (VIZIONS)

    Get PDF
    The Vietnam Initiative for Zoonotic Infections (VIZIONS) includes community-based 'high-risk sentinel cohort' (HRSC) studies investigating individuals at risk of zoonotic infection due to occupational or residential exposure to animals. A total of 852 HRSC members were recruited between March 2013 and August 2014 from three provinces (Ha Noi, Dak Lak, and Dong Thap). The most numerous group (72.8%) corresponded to individuals living on farms, followed by slaughterers (16.3%) and animal health workers (8.5%). Nasal/pharyngeal and rectal swabs were collected from HRSC members at recruitment and after notifying illness. Exposure to exotic animals (including wild pigs, porcupine, monkey, civet, bamboo rat and bat) was highest for the Dak Lak cohort (53.7%), followed by Ha Noi (13.7%) and Dong Thap (4.0%). A total of 26.8% of individuals reported consumption of raw blood over the previous year; 33.6% slaughterers reported no use of protective equipment at work. Over 686 person-years of observation, 213 episodes of suspect infectious disease were notified, equivalent of 0.35 reports per person-year. Responsive samples were collected from animals in the farm cohort. There was noticeable time and space clustering of disease episodes suggesting that the VIZIONS set up is also suitable for the formal epidemiological investigation of disease outbreaks

    An Outbreak of Severe Infections with Community-Acquired MRSA Carrying the Panton-Valentine Leukocidin Following Vaccination

    Get PDF
    Background: Infections with community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA) are emerging worldwide. We investigated an outbreak of severe CA-MRSA infections in children following out-patient vaccination. Methods and Findings: We carried out a field investigation after adverse events following immunization (AEFI) were reported. We reviewed the clinical data from all cases. S. aureus recovered from skin infections and from nasal and throat swabs were analyzed by pulse-field gel electrophoresis, multi locus sequence typing, PCR and microarray. In May 2006, nine children presented with AEFI, ranging from fatal toxic shock syndrome, necrotizing soft tissue infection, purulent abscesses, to fever with rash. All had received a vaccination injection in different health centres in one District of Ho Chi Minh City. Eight children had been vaccinated by the same health care worker (HCW). Deficiencies in vaccine quality, storage practices, or preparation and delivery were not found. Infection control practices were insufficient. CA-MRSA was cultured in four children and from nasal and throat swabs from the HCW. Strains from children and HCW were indistinguishable. All carried the Panton-Valentine leukocidine (PVL), the staphylococcal enterotoxin B gene, the gene complex for staphylococcal-cassette-chromosome mec type V, and were sequence type 59. Strain HCM3A is epidemiologically unrelated to a strain of ST59 prevalent in the USA, althoughthey belong to the same lineage. Conclusions. We describe an outbreak of infections with CA-MRSA in children, transmitted by an asymptomatic colonized HCW during immunization injection. Consistent adherence to injection practice guidelines is needed to prevent CA-MRSA transmission in both in- and outpatient settings

    Safety and efficacy of fluoxetine on functional outcome after acute stroke (AFFINITY): a randomised, double-blind, placebo-controlled trial

    Get PDF
    Background Trials of fluoxetine for recovery after stroke report conflicting results. The Assessment oF FluoxetINe In sTroke recoverY (AFFINITY) trial aimed to show if daily oral fluoxetine for 6 months after stroke improves functional outcome in an ethnically diverse population. Methods AFFINITY was a randomised, parallel-group, double-blind, placebo-controlled trial done in 43 hospital stroke units in Australia (n=29), New Zealand (four), and Vietnam (ten). Eligible patients were adults (aged ≥18 years) with a clinical diagnosis of acute stroke in the previous 2–15 days, brain imaging consistent with ischaemic or haemorrhagic stroke, and a persisting neurological deficit that produced a modified Rankin Scale (mRS) score of 1 or more. Patients were randomly assigned 1:1 via a web-based system using a minimisation algorithm to once daily, oral fluoxetine 20 mg capsules or matching placebo for 6 months. Patients, carers, investigators, and outcome assessors were masked to the treatment allocation. The primary outcome was functional status, measured by the mRS, at 6 months. The primary analysis was an ordinal logistic regression of the mRS at 6 months, adjusted for minimisation variables. Primary and safety analyses were done according to the patient's treatment allocation. The trial is registered with the Australian New Zealand Clinical Trials Registry, ACTRN12611000774921. Findings Between Jan 11, 2013, and June 30, 2019, 1280 patients were recruited in Australia (n=532), New Zealand (n=42), and Vietnam (n=706), of whom 642 were randomly assigned to fluoxetine and 638 were randomly assigned to placebo. Mean duration of trial treatment was 167 days (SD 48·1). At 6 months, mRS data were available in 624 (97%) patients in the fluoxetine group and 632 (99%) in the placebo group. The distribution of mRS categories was similar in the fluoxetine and placebo groups (adjusted common odds ratio 0·94, 95% CI 0·76–1·15; p=0·53). Compared with patients in the placebo group, patients in the fluoxetine group had more falls (20 [3%] vs seven [1%]; p=0·018), bone fractures (19 [3%] vs six [1%]; p=0·014), and epileptic seizures (ten [2%] vs two [<1%]; p=0·038) at 6 months. Interpretation Oral fluoxetine 20 mg daily for 6 months after acute stroke did not improve functional outcome and increased the risk of falls, bone fractures, and epileptic seizures. These results do not support the use of fluoxetine to improve functional outcome after stroke
    corecore