9 research outputs found

    Methodology paper: a novel phantom setup for commissioning of scanned ion beam delivery and TPS

    Get PDF
    Background: Commissioning of treatment planning systems (TPS) and beam delivery for scanned light ion beams is an important quality assurance task. This requires measurement of large sets of high quality dosimetric data in anthropomorphic phantoms to benchmark the TPS and dose delivery under realistic conditions. Method: A novel measurement setup is described, which allows for an efficient collection of a large set of accurate dose data in complex phantom geometries. This setup allows dose measurements based on a set of 24 small volume ionization chambers calibrated in dose to water and mounted in a holder, which can be freely positioned in a water phantom with various phantoms mounted in front of the water tank. The phantoms can be scanned in a CT and a CT-based treatment planning can be performed for a direct benchmark of the dose calculation algorithm in various situations. Results: The system has been used for acceptance testing in scanned light ion beam therapy at Heidelberg Ion Beam Therapy Center for scanned proton and carbon ion beams. It demonstrated to be useful to collect large amounts of high quality data for comparison with the TPS calculation using various phantom geometries. Conclusion: The setup is an efficient tool for commissioning and verification of treatment planning systems. It is especially suited for dynamic beam delivery, as many data points can be obtained during a single plan delivery, but can be adapted also for other dynamic therapies, like rotational IMRT

    Improvements in the Fragmentation Model of SHIELD-HIT08

    No full text

    Nuclear physics in particle therapy: a review

    No full text

    Rivaroxaban or aspirin for patent foramen ovale and embolic stroke of undetermined source: a prespecified subgroup analysis from the NAVIGATE ESUS trial

    No full text
    Background: Patent foramen ovale (PFO) is a contributor to embolic stroke of undetermined source (ESUS). Subgroup analyses from previous studies suggest that anticoagulation could reduce recurrent stroke compared with antiplatelet therapy. We hypothesised that anticoagulant treatment with rivaroxaban, an oral factor Xa inhibitor, would reduce the risk of recurrent ischaemic stroke compared with aspirin among patients with PFO enrolled in the NAVIGATE ESUS trial. Methods: NAVIGATE ESUS was a double-blinded, randomised, phase 3 trial done at 459 centres in 31 countries that assessed the efficacy and safety of rivaroxaban versus aspirin for secondary stroke prevention in patients with ESUS. For this prespecified subgroup analysis, cohorts with and without PFO were defined on the basis of transthoracic echocardiography (TTE) and transoesophageal echocardiography (TOE). The primary efficacy outcome was time to recurrent ischaemic stroke between treatment groups. The primary safety outcome was major bleeding, according to the criteria of the International Society of Thrombosis and Haemostasis. The primary analyses were based on the intention-to-treat population. Additionally, we did a systematic review and random-effects meta-analysis of studies in which patients with cryptogenic stroke and PFO were randomly assigned to receive anticoagulant or antiplatelet therapy. Findings: Between Dec 23, 2014, and Sept 20, 2017, 7213 participants were enrolled and assigned to receive rivaroxaban (n=3609) or aspirin (n=3604). Patients were followed up for a mean of 11 months because of early trial termination. PFO was reported as present in 534 (7·4%) patients on the basis of either TTE or TOE. Patients with PFO assigned to receive aspirin had a recurrent ischaemic stroke rate of 4·8 events per 100 person-years compared with 2·6 events per 100 person-years in those treated with rivaroxaban. Among patients with known PFO, there was insufficient evidence to support a difference in risk of recurrent ischaemic stroke between rivaroxaban and aspirin (hazard ratio [HR] 0·54; 95% CI 0·22–1·36), and the risk was similar for those without known PFO (1·06; 0·84–1·33; pinteraction=0·18). The risks of major bleeding with rivaroxaban versus aspirin were similar in patients with PFO detected (HR 2·05; 95% CI 0·51–8·18) and in those without PFO detected (HR 2·82; 95% CI 1·69–4·70; pinteraction=0·68). The random-effects meta-analysis combined data from NAVIGATE ESUS with data from two previous trials (PICSS and CLOSE) and yielded a summary odds ratio of 0·48 (95% CI 0·24–0·96; p=0·04) for ischaemic stroke in favour of anticoagulation, without evidence of heterogeneity. Interpretation: Among patients with ESUS who have PFO, anticoagulation might reduce the risk of recurrent stroke by about half, although substantial imprecision remains. Dedicated trials of anticoagulation versus antiplatelet therapy or PFO closure, or both, are warranted. Funding: Bayer and Janssen

    Rivaroxaban or aspirin for patent foramen ovale and embolic stroke of undetermined source: a prespecified subgroup analysis from the NAVIGATE ESUS trial

    No full text
    corecore