324 research outputs found

    Experimental investigation of a simulated LOX injector flow field and other nonintrusive measurement efforts

    Get PDF
    Efforts to improve the characteristics of fuel-oxidizer mixing in liquid rocket combustors have lead to a swirl element design for a liquid oxygen injector which is being considered for use on the STME. For the design which is the subject of this investigation, the oxygen enters the injector element perpendicular to the injector axis and nearly tangent to the circular injector wall. This swirl element is at one end of a tube and the injector exit is at the other. This geometric configuration creates a plume in the shape of a conical sheet. This sheet is either primarily contiguous liquid or droplets depending on the pressure drop in the injector and the distance from the injector exit. Probe-based devices such as two-dimensional grid patternators have been used to investigate simulated LOX injector flow fields (Hulka). The primary work described herein is an effort to use optical techniques to investigate the plume of a swirl injector element. For this investigation, a high pressure (500 psig) cold flow test facility was constructed. Water was used as the LOX simulate and air pressure was used to drive the injector flow field. Laser-induced fluorescence (LIF) from dye seeded into the water was used to obtain quantitative measurements of the time-averaged water concentration distribution in the plume. Scattered laser light and LIF were used for time averaged plume visualization and scattered light from a strobe with a 1 microsecond pulse was used for time-resolved plume visualization. During the Summer Faculty Fellowship for which this report was developed, an additional effort, unrelated to the swirl injector investigation, was made to resolve fluctuations in the combustion product composition in the exhaust of a hybrid rocket motor. A brief description of this effort is included herein

    A Detailed Investigation of Staged Normal Injection into a Mach 2 Flow

    Get PDF
    A study of the staged injection of two jets of air behind a rearward facing step into a Mach 2 flow was performed using the SPARK 3-D Navier-Stokes code. Calculated mole fraction distributions were compared with an extensive set of planar mole fraction measurements made with a laser induced iodine fluorescence technique. A statistical measure, the standard deviation, was used to help assess agreement between calculation and experiment. Overall, good agreement was found between calculated and measured values. Generally, agreement was better in the far field of the injectors. The effect of grid resolution was investigated by calculating solutions on grids of 60,000, 200,000, and 450,000 points. Differences in the solutions on the two finer grids were small. However, the mole fraction distributions were distinguishable. The effect of turbulence modeling was investigated by employing three different algebraic models for the jet turbulence: the Baldwin-Lomax model, the Prandtl mixing length model, and the Eggers mixing length model. Overall, the Eggers mixing length model was found to be superior for this case. Finally, the effect of the jet exit conditions was examined. A recently proposed Mach number distribution at the jet exit was found to slightly improve agreement between measurement and calculation

    Surface film effects during cyclic deformation of dislocation-mobility-limited materials

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/30047/1/0000415.pd

    Demes:A standard format for demographic models

    Get PDF
    Understanding the demographic history of populations is a key goal in population genetics, and with improving methods and data, ever more complex models are being proposed and tested. Demographic models of current interest typically consist of a set of discrete populations, their sizes and growth rates, and continuous and pulse migrations between those populations over a number of epochs, which can require dozens of parameters to fully describe. There is currently no standard format to define such models, significantly hampering progress in the field. In particular, the important task of translating the model descriptions in published work into input suitable for population genetic simulators is labor intensive and error prone. We propose the Demes data model and file format, built on widely used technologies, to alleviate these issues. Demes provide a well-defined and unambiguous model of populations and their properties that is straightforward to implement in software, and a text file format that is designed for simplicity and clarity. We provide thoroughly tested implementations of Demes parsers in multiple languages including Python and C, and showcase initial support in several simulators and inference methods. An introduction to the file format and a detailed specification are available at https://popsim-consortium.github.io/demes-spec-docs/

    A Current Mode Detector Array for Gamma-Ray Asymmetry Measurements

    Full text link
    We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high cold neutron flux, control of systematic errors at the ppb level, and the use of current mode gamma-ray detection with vacuum photo diodes and low-noise solid-state preamplifiers. The average detector photoelectron yield was determined to be 1300 photoelectrons per MeV. The RMS width seen in the measurement is therefore dominated by the fluctuations in the number of gamma rays absorbed in the detector (counting statistics) rather than the intrinsic detector noise. The detectors were tested for noise performance, sensitivity to magnetic fields, pedestal stability and cosmic background. False asymmetries due to gain changes and electronic pickup in the detector system were measured to be consistent with zero to an accuracy of 10−910^{-9} in a few hours. We report on the design, operating criteria, and the results of measurements performed to test the detector array.Comment: 33 pages, 20 figures, 2 table

    Bayesian Best-Arm Identification for Selecting Influenza Mitigation Strategies

    Full text link
    Pandemic influenza has the epidemic potential to kill millions of people. While various preventive measures exist (i.a., vaccination and school closures), deciding on strategies that lead to their most effective and efficient use remains challenging. To this end, individual-based epidemiological models are essential to assist decision makers in determining the best strategy to curb epidemic spread. However, individual-based models are computationally intensive and it is therefore pivotal to identify the optimal strategy using a minimal amount of model evaluations. Additionally, as epidemiological modeling experiments need to be planned, a computational budget needs to be specified a priori. Consequently, we present a new sampling technique to optimize the evaluation of preventive strategies using fixed budget best-arm identification algorithms. We use epidemiological modeling theory to derive knowledge about the reward distribution which we exploit using Bayesian best-arm identification algorithms (i.e., Top-two Thompson sampling and BayesGap). We evaluate these algorithms in a realistic experimental setting and demonstrate that it is possible to identify the optimal strategy using only a limited number of model evaluations, i.e., 2-to-3 times faster compared to the uniform sampling method, the predominant technique used for epidemiological decision making in the literature. Finally, we contribute and evaluate a statistic for Top-two Thompson sampling to inform the decision makers about the confidence of an arm recommendation

    Symphysiotomy in Zimbabwe; Postoperative Outcome, Width of the Symphysis Joint, and Knowledge, Attitudes and Practice among Doctors and Midwives

    Get PDF
    BACKGROUND: Obstructed labour remains one of the leading causes of maternal and foetal death and morbidity in poorly resourced areas of the world, where the 24 hours availability of a caesarean section (CS) cannot be guaranteed, and the CS related mortality rate is still high. In these settings, reinstatement of symphysiotomy has been advocated. The objectives were, in1994; to study perioperative and long-term complications of symphysiotomy and compare them to those related to CS for similar indications, in 1996; to measure the symphyseal width after symphysiotomy and compare it to that after normal vaginal delivery, and, in 1998; to assess knowledge, attitudes and practice related to symphysiotomy among doctors and midwives in Zimbabwe. METHODS AND FINDINGS: Thirty-four women who had undergone symphysiotomy and 29 women who had undergone a CS for obstructed labour were interviewed. The symphyseal widths of 19 women with a previous symphysiotomy were compared to that of 92 women with previous normal vaginal deliveries, using ultrasound technique. Forty-one doctors and 39 midwives, in three central hospitals and seven district hospitals in Zimbabwe, were interviewed about symphysiotomy. None of the 34 women reported serious soft tissue injuries or infections post symphysiotomy. Long-term complications after symphysiotomy do not differ notably from those after CS for similar indications. The intra-articular width of the symphysis pubis is increased after a symphysiotomy. Seventy-nine of the 80 interviewed health care workers knew about symphysiotomy. One obstetrician had performed symphysiotomies. Two-thirds of the participants considered symphysiotomy an obsolete and second-class operation, but lifesaving and appropriate in remote areas of Zimbabwe. Ten of 13 midwives in remote areas wanted to carry out symphysiotomies themselves. CONCLUSIONS: No severe complications due to symphysiotomy were revealed in this study. The results suggest that a modest permanent enlargement of the pelvis post symphysiotomy (together with the absence of a scarred uterus) may facilitate subsequent vaginal delivery. Doctors and midwives working in district hospitals have a more positive attitude to symphysiotomies than the colleagues in central hospitals. Obstetricians (who would have to do the teaching), working in the large urban hospitals almost exclude symphysiotomy as an alternative management in Zimbabwe

    Polarized He-3 gas compression system using metastability-exchange optical pumping

    Get PDF
    Dense samples (10-100 bar cm) of nuclear spin polarized He-3 are utilized in high energy physics, neutron scattering, atomic physics, and magnetic resonance imaging. Metastability exchange optical pumping can rapidly produce high He-3 polarizations (≈ 80%) at low pressures (few mbar). We describe a polarized He-3 gas compressor system which accepts 0.26 bar l h(-1) of He-3 gas polarized to 70% by a 4 W neodymium doped lanthanum magnesium hexaluminate (Nd:LMA) laser and compresses it into a 5 bar cm target with final polarization of 55%. The spin relaxation rates of the system\u27s components have been measured using nuclear magnetic resonance and a model of the He-3 polarization loss based on the measured relaxation rates and the gas flow is in agreement with a He-3 polarization measurement using neutron transmission. © 2005 American Institute of Physics
    • …
    corecore