136 research outputs found

    In vivo Imaging of Bile Accumulation and Biliary Infarction after Common Bile Duct Ligation in Rats

    Get PDF
    Obstructive cholestasis is caused by mechanical constriction or occlusion leading to reduced bile flow. Serious complications such as jaundice and even death may follow. Little is known about the initial phase of cholestasis and its consequences for the hepatic microarchitecture. This in vivo study aimed to characterize the nature and kinetics of developing obstructive cholestasis and focused on areas with biliary stasis and infarction by visualizing the autofluorescence of bile acids using intravital microscopy of the liver over a period of 30 h after bile duct ligation in rats. The innovation resided in performing fluorescence microscopy without applying fluorescent dyes. In animals subjected to obstructive cholestasis, the most significant changes observed in vivo were the concomitant appearance of (1) areas with bile accumulation increasing in size (6 h: 0.163 ± 0.043, 18 h: 0.180 ± 0.086, 30 h: 0.483 ± 0.176 mm2/field) and (2) areas with biliary infarction (6 h: 0.011 ± 0.006, 18 h: 0.010 ± 0.004, 30 h: 0.010 ± 0.050 mm2/field) as well as (3) a relation between the formation of hepatic lesions and enzyme activity in serum. The sequential in vivo analysis presented herein is a new method for the in vivo visualization of the very early changes in the hepatic parenchyma caused by obstructive cholestasis

    Practice of skin protection and skin care among German surgeons and influence on the efficacy of surgical hand disinfection and surgical glove perforation

    Get PDF
    Background: Surgical hand rub and healthy skin are basic requirements to prevent surgical site infections. Nevertheless, there is little knowledge about the current practice of skin protection and/or skin care products (SP/SC) using among surgeons as well as a lack of data pertaining to the influence of SP/SC on the antimicrobial efficacy of surgical hand rub. Methods: A 10 weeks-survey among German surgeons as well as an experimental crossover study involving 26 participants were conducted. The immediate and sustainable efficacy (IE/SE) of surgical hand rub and participants’ hand moisture were measured after an 8-day usage of SP/SC, as well as the influence on micro-perforations on surgical gloves. Results: The questionnaire was available to 16,000 German surgeons. Thereof, 1,771 surgeons accessed the questionnaire, representing a total participation rate of 11%. As 19% (n = 338) of questionnaires were incomplete, a total of 1,433 completed questionnaires were available for further analysis. More than 75% of the participants stated not to use any SP/SC, yet, almost 50% suffered from skin irritation or discomfort. Only 5% used SP/SC at the beginning of their shift. 10% refused to use SP/SC because of concerns that SP/SC may reduce the antimicrobial efficacy of surgical hand rub. After usage of SP/SC over 8-days, skin moisture was significantly higher (P < 0.001), whereas no significant influence on the antimicrobial efficacy of surgical hand rub was observed (IE: P = 0.135; SP: P = 0.681). Micro-perforations were detected in 8/52 surgical gloves (15%), with no statistical significant difference between SP/SC users (n = 2/26; 8%) and non-users (n = 6/26; 23%; P = 0.249). Conclusions: Following the results of this largest questionnaire base survey among German surgeons on skin care, there is a need to educate and inform surgeons on the correct application and the concept of SP/SC strategies. In the present study, the combination of selected SP/SC products and one alcohol-based hand rub formulation did not show a negative interaction with surgical hand rub or surgical glove perforation. However, it is advisable to ascertain the compatibility of SP/SC products with the used hand disinfectant prior to purchase

    Antibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use

    Get PDF
    Background: A surgical glove will protect surgeons and patients only if the glove’s integrity remains intact. However, several studies have demonstrated that undetected micro-perforations of surgical gloves are common. Because of the possibility of surgical glove puncture, an antimicrobial surgical glove was developed. The aim of this laboratory based experimental study was to assess the antibacterial efficacy of the interior chlorhexidine-gluconate (CHG)-coat of an antimicrobial synthetic polyisoprene surgical glove by using a standardized microbiological challenge. Methods: Sixteen healthy adult participants donned one antimicrobial surgical glove and one non-antimicrobial surgical glove randomly allocated to their dominant and non-dominant hand following a crossover design. During a 2-h wear time, participants performed standardized finger and hand movements. Thereafter, the interior surface of excised fingers of the removed gloves was challenged with 8.00 log10 cfu/mL S. aureus (ATCC 6538) or K. pneumoniae (ATCC 4352), respectively. The main outcome measure was the viable mean log10 cfu counts of the two glove groups after 5 min contact with the interior glove’s surface. Results: When comparing an antimicrobial glove against an untreated reference glove after 2-h simulated use wear-time, a mean reduction factor of 6.24 log10 (S. aureus) and 6.22 log10 (K. pneumoniae) was achieved after 5 min contact. Conclusion: These results demonstrate that wearing antibacterial gloves on hands does not negatively impact their antibacterial activity after 2-h of wear. This may have a potential benefit for patient safety in case of glove puncture during surgical procedures

    Hydroxylases regulate intestinal fibrosis through the suppression of ERK mediated TGF-β1 signaling

    Get PDF
    Fibrosis is a complication of chronic inflammatory disorders such as inflammatory bowel disease (IBD), a condition which has limited therapeutic options and often requires surgical intervention. Pharmacologic inhibition of oxygen-sensing prolyl hydroxylases (PHD), which confer oxygen-sensitivity upon the hypoxia inducible factor (HIF) pathway, has recently been shown to have therapeutic potential in colitis, although the mechanisms involved remain unclear. Here, we investigated the impact of hydroxylase inhibition on inflammation-driven fibrosis in a murine colitis model. Mice exposed to dextran sodium sulfate followed by period of recovery developed intestinal fibrosis characterized by alterations in the pattern of collagen deposition and infiltration of activated fibroblasts. Treatment with the hydroxylase inhibitor dimethyloxalylglycine (DMOG) ameliorated fibrosis. TGF-β1 is a key regulator of fibrosis which acts through the activation of fibroblasts. Hydroxylase inhibition reduced TGF-β1-induced expression of fibrotic markers in cultured fibroblasts suggesting a direct role for hydroxylases in TGF-β1 signalling. This was at least in part due to inhibition of non-canonical activation of extracellular signal-regulated kinase (ERK) signalling. In summary, pharmacologic hydroxylase inhibition ameliorates intestinal fibrosis, through suppression of TGF-β1-dependent ERK activation in fibroblasts. We hypothesize that in addition to previously reported immunosupressive effects, hydroxylase inhibitors independently suppress pro-fibrotic pathway

    Hand antisepsis without decreasing efficacy by shortening the rub-in time of alcohol-based handrubs to 15 seconds

    Get PDF
    BackgroundA previous study among neonatal intensive care unit (NICU) nurses showed that the antibacterial efficacy of alcohol-based handrubs (ABHR) can be achieved in 15 s instead of 30 s with a significant increase in the frequency of hand antisepsis. This study aimed to examine 15-s vs 30-s antisepsis performance by measuring microbial load on fingertips and compliance among nurses in a low-risk gynaecological ward.MethodsAn independent trained observer monitored the frequency and compliance with hand antisepsis during shifts in a crossover design. Fingertips including thumbs were rinsed in soy broth before hand rubbing at the beginning of a shift and then hourly to determine the bacterial load. Performance activity was assigned to the contamination class of the Fulkerson scale. Immediately before the lunch break, volunteers cleaned their hands for a randomly determined application time of 15 or 30 s.ResultsExamination of bacterial load on fingertips revealed no difference between 15 vs 30 s application time. Controlled hand antisepsis before the lunch break also showed no difference in efficacy for either test series. Participants rubbing for 15 s were more likely to perform hand antisepsis compared with those rubbing for 30 s ( P=0.2). The compliance increased from 54.7% to 69.5% in the 15-s trial.DiscussionShortening the duration for hand antisepsis did not decrease efficacy. Shortening the application time to 15 s should be considered within the critical components of a successful multimodal intervention strategy to improve hand-hygiene compliance in clinical practice

    Bacterial migration through punctured surgical gloves under real surgical conditions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions.</p> <p>Methods</p> <p>An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab.</p> <p>Results</p> <p>In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves) were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes). Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25%) punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98) of outer gloves and in 1% (1/96) of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers), the calculated migration was 50% (n = 5). The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes.</p> <p>Conclusions</p> <p>This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.</p

    Management des zirkumportalen Pankreas: eine Herausforderung in der Pankreaschirurgie

    No full text
    • …