1,477 research outputs found

    The extraordinary evolutionary history of the reticuloendotheliosis viruses

    Get PDF
    The reticuloendotheliosis viruses (REVs) comprise several closely related amphotropic retroviruses isolated from birds. These viruses exhibit several highly unusual characteristics that have not so far been adequately explained, including their extremely close relationship to mammalian retroviruses, and their presence as endogenous sequences within the genomes of certain large DNA viruses. We present evidence for an iatrogenic origin of REVs that accounts for these phenomena. Firstly, we identify endogenous retroviral fossils in mammalian genomes that share a unique recombinant structure with REVs—unequivocally demonstrating that REVs derive directly from mammalian retroviruses. Secondly, through sequencing of archived REV isolates, we confirm that contaminated Plasmodium lophurae stocks have been the source of multiple REV outbreaks in experimentally infected birds. Finally, we show that both phylogenetic and historical evidence support a scenario wherein REVs originated as mammalian retroviruses that were accidentally introduced into avian hosts in the late 1930s, during experimental studies of P. lophurae, and subsequently integrated into the fowlpox virus (FWPV) and gallid herpesvirus type 2 (GHV-2) genomes, generating recombinant DNA viruses that now circulate in wild birds and poultry. Our findings provide a novel perspective on the origin and evolution of REV, and indicate that horizontal gene transfer between virus families can expand the impact of iatrogenic transmission events

    Neurobehavioral consequences of chronic intrauterine opioid exposure in infants and preschool children: a systematic review and meta-analysis

    Get PDF
    <b>Background</b><p></p> It is assumed within the accumulated literature that children born of pregnant opioid dependent mothers have impaired neurobehavioral function as a consequence of chronic intrauterine opioid use.<p></p> <b>Methods</b><p></p> Quantitative and systematic review of the literature on the consequences of chronic maternal opioid use during pregnancy on neurobehavioral function of children was conducted using the Meta-analysis of Observational Studies in Epidemiology (MOOSE) and the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. We searched Cinahl, EMBASE, PsychINFO and MEDLINE between the periods of January 1995 to January 2012.<p></p> <b>Results</b><p></p> There were only 5 studies out of the 200 identified that quantitatively reported on neurobehavioral function of children after maternal opioid use during pregnancy. All 5 were case control studies with the number of exposed subjects within the studies ranging from 33–143 and 45–85 for the controls. This meta-analysis showed no significant impairments, at a non-conservative significance level of p < 0.05, for cognitive, psychomotor or observed behavioural outcomes for chronic intra-uterine exposed infants and pre-school children compared to non-exposed infants and children. However, all domains suggested a trend to poor outcomes in infants/children of opioid using mothers. The magnitude of all possible effects was small according to Cohen’s benchmark criteria.<p></p> <b>Conclusions</b><p></p> Chronic intra-uterine opioid exposed infants and pre-school children experienced no significant impairment in neurobehavioral outcomes when compared to non-exposed peers, although in all domains there was a trend to poorer outcomes. The findings of this review are limited by the small number of studies analysed, the heterogenous populations and small numbers within the individual studies. Longitudinal studies are needed to determine if any neuropsychological impairments appear after the age of 5 years and to help investigate further the role of environmental risk factors on the effect of ‘core’ phenotypes

    Adaptation to motor-visual and motor-auditory temporal lags transfer across modalities

    Get PDF
    Previous research has shown that the timing of a sensor-motor event is recalibrated after a brief exposure to a delayed feedback of a voluntary action (Stetson et al. 2006). Here, we examined whether it is the sensory or motor event that is shifted in time. We compared lag adaption for action-feedback in visuo-motor pairs and audio-motor pairs using an adaptation-test paradigm. Participants were exposed to a constant lag (50 or 150 ms) between their voluntary action (finger tap) and its sensory feedback (flash or tone pip) during an adaptation period (~3 min). Immediately after that, they performed a temporal order judgment (TOJ) task about the tap-feedback test stimulus pairings. The modality of the feedback stimulus was either the same as the adapted one (within-modal) or different (cross-modal). The results showed that the point of subjective simultaneity (PSS) was uniformly shifted in the direction of the exposed lag within and across modalities (motor-visual, motor-auditory). This suggests that the TRE of sensor-motor events is mainly caused by a shift in the motor component

    Methods for specifying the target difference in a randomised controlled trial : the Difference ELicitation in TriAls (DELTA) systematic review

    Get PDF
    Peer reviewedPublisher PD

    CMB Telescopes and Optical Systems

    Full text link
    The cosmic microwave background radiation (CMB) is now firmly established as a fundamental and essential probe of the geometry, constituents, and birth of the Universe. The CMB is a potent observable because it can be measured with precision and accuracy. Just as importantly, theoretical models of the Universe can predict the characteristics of the CMB to high accuracy, and those predictions can be directly compared to observations. There are multiple aspects associated with making a precise measurement. In this review, we focus on optical components for the instrumentation used to measure the CMB polarization and temperature anisotropy. We begin with an overview of general considerations for CMB observations and discuss common concepts used in the community. We next consider a variety of alternatives available for a designer of a CMB telescope. Our discussion is guided by the ground and balloon-based instruments that have been implemented over the years. In the same vein, we compare the arc-minute resolution Atacama Cosmology Telescope (ACT) and the South Pole Telescope (SPT). CMB interferometers are presented briefly. We conclude with a comparison of the four CMB satellites, Relikt, COBE, WMAP, and Planck, to demonstrate a remarkable evolution in design, sensitivity, resolution, and complexity over the past thirty years.Comment: To appear in: Planets, Stars and Stellar Systems (PSSS), Volume 1: Telescopes and Instrumentatio
    corecore