287 research outputs found

    A superconducting transformer system for high current cable testing

    Full text link
    This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples

    A proof-of-concept Bitter-like HTS electromagnet fabricated from a silver-infiltrated (RE)BCO ceramic bulk

    Get PDF
    A novel concept for a compact high-field magnet coil is introduced. This is based on stacking slit annular discs cut from bulk rare-earth barium cuprate ((RE)BCO) ceramic in a Bitter-like architecture. Finite-element modelling shows that a small 20 turn stack (with a total coil volume of <20 cm3) is capable of generating a central bore magnetic field of >2 T at 77 K and >20 T at 30 K. Unlike resistive Bitter magnets, the high-temperature superconducting (HTS) Bitter stack exhibits significant non-linear field behaviour during current ramping, caused by current filling proceeding from the inner radius outwards in each HTS layer. Practical proof-of-concept for this architecture was then demonstrated through fabricating an uninsulated four-turn prototype coil stack and operating this at 77 K. A maximum central field of 0.382 T was measured at 1.2 kA, with an accompanying 6.1 W of internal heat dissipation within the coil. Strong magnetic hysteresis behaviour was observed within the prototype coil, with ≈30% of the maximum central field still remaining trapped 45 min after the current had been removed. The coil was thermally stable during a 15 min hold at 1 kA, and survived thermal cycling to room temperature without noticeable deterioration in performance. A final test-to-destruction of the coil showed that the limiting weak point in the stack was growth-sector boundaries present in the original (RE)BCO bulk

    Genome wide analysis of gene expression changes in skin from patients with type 2 diabetes

    Get PDF
    Non-healing chronic ulcers are a serious complication of diabetes and are a major healthcare problem. While a host of treatments have been explored to heal or prevent these ulcers from forming, these treatments have not been found to be consistently effective in clinical trials. An understanding of the changes in gene expression in the skin of diabetic patients may provide insight into the processes and mechanisms that precede the formation of non-healing ulcers. In this study, we investigated genome wide changes in gene expression in skin between patients with type 2 diabetes and non-diabetic patients using next generation sequencing. We compared the gene expression in skin samples taken from 27 patients (13 with type 2 diabetes and 14 non-diabetic). This information may be useful in identifying the causal factors and potential therapeutic targets for the prevention and treatment of diabetic related diseases

    Sensitive Spectroscopic Detection of Large and Denatured Protein Aggregates in Solution by Use of the Fluorescent Dye Nile Red

    Get PDF
    The fluorescent dye Nile red was used as a probe for the sensitive detection of large, denatured aggregates of the model protein β-galactosidase (E. coli) in solution. Aggregates were formed by irreversible heat denaturation of β-galactosidase below and above the protein’s unfolding temperature of 57.4°C, and the presence of aggregates in heated solutions was confirmed by static light scattering. Interaction of Nile red with β-galactosidase aggregates led to a shift of the emission maximum (λmax) from 660 to 611 nm, and to an increase of fluorescence intensity. Time-resolved fluorescence and fluorescence correlation spectroscopy (FCS) measurements showed that Nile red detected large aggregates with hydrodynamic radii around 130 nm. By steady-state fluorescence measurements, it was possible to detect 1 nM of denatured and aggregated β-galactosidase in solution. The comparison with size exclusion chromatography (SEC) showed that native β-galactosidase and small aggregates thereof had no substantial effect on the fluorescence of Nile red. Large aggregates were not detected by SEC, because they were excluded from the column. The results with β-galactosidase demonstrate the potential of Nile red for developing complementary analytical methods that overcome the size limitations of SEC, and can detect the formation of large protein aggregates at early stages

    Generation of subject-specific, dynamic, multisegment ankle and foot models to improve orthotic design: a feasibility study

    Get PDF
    ABSTRACT: BACKGROUND: Currently, custom foot and ankle orthosis prescription and design tend to be based on traditional techniques, which can result in devices which vary greatly between clinicians and repeat prescription. The use of computational models of the foot may give further insight in the biomechanical effects of these devices and allow a more standardised approach to be taken to their design, however due to the complexity of the foot the models must be highly detailed and dynamic. METHODS: Functional and anatomical datasets will be collected in a multicentre study from 10 healthy participants and 15 patients requiring orthotic devices. The patient group will include individuals with metarsalgia, flexible flat foot and drop foot. Each participant will undergo a clinical foot function assessment, 3D surface scans of the foot under different loading conditions, and detailed gait analysis including kinematic, kinetic, muscle activity and plantar pressure measurements in both barefoot and shod conditions. Following this each participant will undergo computed tomography (CT) imaging of their foot and ankle under a range of loads and positions while plantar pressures are recorded. A further subgroup of participants will undergo magnetic resonance imaging (MRI) of the foot and ankle. Imaging data will be segmented to derive the size of bones and orientation of the joint axes. Insertion points of muscles and ligaments will be determined from the MRI and CT-scans and soft tissue material properties computed from the loaded CT data in combination with the plantar pressure measurements. Gait analysis data will be used to drive the models and in combination with the 3D surface scans for scaling purposes. Predicted plantar pressures and muscle activation patterns predicted from the models will be compared to determine the validity of the models. DISCUSSION: This protocol will lead to the generation of unique datasets which will be used to develop linked inverse dynamic and forward dynamic biomechanical foot models. These models may be beneficial in predicting the effect of and thus improving the efficacy of orthotic devices for the foot and ankle

    An interlaboratory study of TEX86 and BIT analysis using high-performance liquid chromatography–mass spectrometry

    Get PDF
    Author Posting. © American Geophysical Union, 2009. This article is posted here by permission of American Geophysical Union for personal use, not for redistribution. The definitive version was published in Geochemistry Geophysics Geosystems 10 (2009): Q03012, doi:10.1029/2008GC002221.Recently, two new proxies based on the distribution of glycerol dialkyl glycerol tetraethers (GDGTs) were proposed, i.e., the TEX86 proxy for sea surface temperature reconstructions and the BIT index for reconstructing soil organic matter input to the ocean. In this study, fifteen laboratories participated in a round robin study of two sediment extracts with a range of TEX86 and BIT values to test the analytical reproducibility and repeatability in analyzing these proxies. For TEX86 the repeatability, indicating intra-laboratory variation, was 0.028 and 0.017 for the two sediment extracts or ±1–2°C when translated to temperature. The reproducibility, indicating among-laboratory variation, of TEX86 measurements was substantially higher, i.e., 0.050 and 0.067 or ±3–4°C when translated to temperature. The latter values are higher than those obtained in round robin studies of Mg/Ca and U37 k′ paleothermometers, suggesting the need to primarily improve compatibility between labs. The repeatability of BIT measurements for the sediment with substantial amounts of soil organic matter input was relatively small, 0.029, but reproducibility was large, 0.410. This large variance could not be attributed to specific equipment used or a particular data treatment. We suggest that this may be caused by the large difference in the molecular weight in the GDGTs used in the BIT index, i.e., crenarchaeol versus the branched GDGTs. Potentially, this difference gives rise to variable responses in the different mass spectrometers used. Calibration using authentic standards is needed to establish compatibility between labs performing BIT measurements
    corecore