121 research outputs found
Recommended from our members
Mapping solar irradiance within Schrödinger Basin for future robotic sample return missions
The US National Research Council (NRC) identified eight scientific concepts and thirty-five prioritized investigations to be addressed with continued lunar exploration. These objectives are broadly consistent with those identified throughout the international community. the majority of these objectives require sample return from the Moon. Schrödinger basin has been highlighted as a particularly attractive location to find suitable samples
Fluorescence Efficiency and Visible Re-emission Spectrum of Tetraphenyl Butadiene Films at Extreme Ultraviolet Wavelengths
A large number of current and future experiments in neutrino and dark matter
detection use the scintillation light from noble elements as a mechanism for
measuring energy deposition. The scintillation light from these elements is
produced in the extreme ultraviolet (EUV) range, from 60 - 200 nm. Currently,
the most practical technique for observing light at these wavelengths is to
surround the scintillation volume with a thin film of Tetraphenyl Butadiene
(TPB) to act as a fluor. The TPB film absorbs EUV photons and reemits visible
photons, detectable with a variety of commercial photosensors. Here we present
a measurement of the re-emission spectrum of TPB films when illuminated with
128, 160, 175, and 250 nm light. We also measure the fluorescence efficiency as
a function of incident wavelength from 120 to 250 nm.Comment: 15 pages, 9 figures, Submitted to Nuclear Instruments and Methods in
Physics Research Section A: Accelerators, Spectrometers, Detectors and
Associated Equipmen
Recommended from our members
Laboratory Measurements of Fe XXIV L-Shell Line Emission
Recent ASCA spectra exhibit discrepancies with the relative line intensities of various Fe XXIII and XXIV L-shell emission lines predicted by standard plasma emission codes. To address this issue, we have carried out a series of high-resolution, broadband measurements of Fe XXIV line emission using an electron beam ion trap facility. X-ray lines produced in the trap are detected and resolved using Bragg crystal spectrometers. We report measurements of 3 → 2 and 4 → 2 transitions, which result primarily from electron impact excitation. Overall, good agreement is found with distorted wave calculations
Recommended from our members
Laboratory Measurements of Fe XXIV L-Shell Line Emission
Recent ASCA spectra exhibit discrepancies with the relative line intensities of various Fe XXIII and XXIV L-shell emission lines predicted by standard plasma emission codes. To address this issue, we have carried out a series of high-resolution, broadband measurements of Fe XXIV line emission using an electron beam ion trap facility. X-ray lines produced in the trap are detected and resolved using Bragg crystal spectrometers. We report measurements of 33 2 and 43 2 transitions, which result primarily from electron impact excitation. Overall, good agreement is found with distorted wave calculations
Momentum-resolved resonant inelastic soft X-ray scattering (qRIXS) endstation at the ALS
A momentum resolved resonant inelastic X-ray scattering (qRIXS) experimental station with continuously rotatable spectrometers and parallel detection is designed to operate at different beamlines at synchrotron and free electron laser (FEL) facilities. This endstation, currently located at the Advanced Light Source (ALS), has five emission ports on the experimental chamber for mounting the high-throughput modular soft X-ray spectrometers (MXS) [24]. Coupled to the rotation from the supporting hexapod, the scattered X-rays from 27.5° (forward scattering) to 152.5° (backward scattering) relative to the incident photon beam can be recorded, enabling the momentum-resolved RIXS spectroscopy. The components of this endstation are described in details, and the preliminary RIXS measurements on highly oriented pyrolytic graphite (HOPG) reveal the low energy vibronic excitations from the strong electron-phonon coupling at C K edge around σ* band. The grating upgrade option to enhance the performance at low photon energies is presented and the potential of this spectroscopy is discussed in summary
Near-Edge X-ray Absorption Fine Structure Study of Ion-beam-induced Phase Transformation in Gd2(Ti1-yZry)2O7
The structural and electronic properties of Gd2(Ti1−yZry)2O7 (y=0–1) pyrochlores following a 2.0-MeV Au2+ ion-beam irradiation (~5.0 X 1014 Au2+/cm2) have been investigated by Ti 2p and O 1s near-edge x-ray absorption fine structure (NEXAFS). The irradiation of Gd2(Ti1−yZry)2O7 leads to the phase transformation from the ordered pyrochlore structure (Fd3m) to the defect fluorite structure (Fm3m) regardless of Zr concentration. Irradiated Gd2(Ti1−yZry)2O7 with y≤0.5 are amorphous, although significant short-range order is present. Contrasting to this behavior, compositions with y≥0.75 retain crystallinity in the defect fluorite structure following irradiation. The local structures of Zr4+ in the irradiated Gd2(Ti1−yZry)2O7 with y≥0.75 determined by NEXAFS are the same as in the cubic fluorite-structured yttria-stabilized zirconia (Y–ZrO2), thereby providing conclusive evidence for the phase transformation. The TiO6 octahedra present in Gd2(Ti1−yZry)2O7 are completely modified by ion-beam irradiation to TiOx polyhedra, and the Ti coordination is increased to eight with longer Ti–O bond distances. The similarity between cation sites and the degree of disorder in Gd2Zr2O7 facilitate the rearrangement and relaxation of Gd, Zr, and O ions/defects. This inhibits amorphization during the ion-beam-induced phase transition to the radiation-resistant defect fluorite structure, which is in contrast to the ordered Gd2Ti2O7
Depth-Resolved Composition and Electronic Structure of Buried Layers and Interfaces in a LaNiO/SrTiO Superlattice from Soft- and Hard- X-ray Standing-Wave Angle-Resolved Photoemission
LaNiO (LNO) is an intriguing member of the rare-earth nickelates in
exhibiting a metal-insulator transition for a critical film thickness of about
4 unit cells [Son et al., Appl. Phys. Lett. 96, 062114 (2010)]; however, such
thin films also show a transition to a metallic state in superlattices with
SrTiO (STO) [Son et al., Appl. Phys. Lett. 97, 202109 (2010)]. In order to
better understand this transition, we have studied a strained LNO/STO
superlattice with 10 repeats of [4 unit-cell LNO/3 unit-cell STO] grown on an
(LaAlO)(SrAlTaO) substrate using soft x-ray
standing-wave-excited angle-resolved photoemission (SWARPES), together with
soft- and hard- x-ray photoemission measurements of core levels and
densities-of-states valence spectra. The experimental results are compared with
state-of-the-art density functional theory (DFT) calculations of band
structures and densities of states. Using core-level rocking curves and x-ray
optical modeling to assess the position of the standing wave, SWARPES
measurements are carried out for various incidence angles and used to determine
interface-specific changes in momentum-resolved electronic structure. We
further show that the momentum-resolved behavior of the Ni 3d eg and t2g states
near the Fermi level, as well as those at the bottom of the valence bands, is
very similar to recently published SWARPES results for a related
LaSrMnO/SrTiO superlattice that was studied using the
same technique (Gray et al., Europhysics Letters 104, 17004 (2013)), which
further validates this experimental approach and our conclusions. Our
conclusions are also supported in several ways by comparison to DFT
calculations for the parent materials and the superlattice, including
layer-resolved density-of-states results
Carbon contamination topography analysis of EUV masks
The impact of carbon contamination on extreme ultraviolet (EUV) masks is significant due to throughput loss and potential effects on imaging performance. Current carbon contamination research primarily focuses on the lifetime of the multilayer surfaces, determined by reflectivity loss and reduced throughput in EUV exposure tools. However, contamination on patterned EUV masks can cause additional effects on absorbing features and the printed images, as well as impacting the efficiency of cleaning process. In this work, several different techniques were used to determine possible contamination topography. Lithographic simulations were also performed and the results compared with the experimental data
Performance of actinic EUVL mask imaging using a zoneplate microscope
The SEMATECH Berkeley Actinic Inspection Tool (AIT) is a dual-mode, scanning and imaging extreme-ultraviolet (EUV) microscope designed for pre-commercial EUV mask research. Dramatic improvements in image quality have been made by the replacement of several critical optical elements, and the introduction of scanning illumination to improve uniformity and contrast. We report high quality actinic EUV mask imaging with resolutions as low as 100-nm half-pitch, (20-nm, 5x wafer equivalent size), and an assessment of the imaging performance based on several metrics. Modulation transfer function (MTF) measurements show high contrast imaging for features sizes close to the diffraction-limit. An investigation of the illumination coherence shows that AIT imaging is much more coherent than previously anticipated, with {sigma} below 0.2. Flare measurements with several line-widths show a flare contribution on the order of 2-3% relative intensity in dark regions above the 1.3% absorber reflectivity on the test mask used for these experiments. Astigmatism coupled with focal plane tilt are the dominant aberrations we have observed. The AIT routinely records 250-350 high-quality images in numerous through-focus series per 8-hour shift. Typical exposure times range from 0.5 seconds during alignment, to approximately 20 seconds for high-resolution images
Performance Characteristics of Beamline 6.3.1 from 200 eV to 2000 eV at the Advanced Light Source
Bend magnet beamline 6.3.1 at the Advanced Light Source operates from 200 eV to 2000 eV, primarily used for x-ray absorption fine structure investigations. The beamline optics consist of a compact, entrance-slitless, Hettrick-Underwood type variable-line-spacing plane-grating monochromator and refocusing mirrors to provide a 25 μm × 500 μm spot at the focal point in the reflectometer end station. Wavelength is scanned by the simple rotation of the grating and illuminates a fixed exit slit. The LabView based beamline control and data acquisition computer code has been implemented to provide a convenient interface to the user. The dedicated end station is a reflectometer that is isolated from the beamline by a differential ion pump. The reflectometer can position samples to within 4 μm with an angular position of 0.002°, has total electron and fluorescence yield detectors, and pumps down in about 30 minutes. External end stations can be mounted downstream of the reflectometer as well. The versatility and simplicity of beamline 6.3.1 have made it useful for a wide range of applications such as the characterization of optical components, reflective coatings, and the investigation of a diverse range of materials in both the solid state and in solution
- …