150 research outputs found
Molecular Dynamics Simulation of Spinodal Decomposition in Three-Dimensional Binary Fluids
Using large-scale molecular dynamics simulations of a two-component
Lennard-Jones model in three dimensions, we show that the late-time dynamics of
spinodal decomposition in concentrated binary fluids reaches a viscous scaling
regime with a growth exponent , in agreement with experiments and a
theoretical analysis for viscous growth.Comment: 4 pages, 3 figure
Long Range Hydration Effects in Electrolytic Free Suspended Black Films
The force law within free suspended black films made of negatively charged
Aerosol-OT (AOT) with added LiCl or CsCl is studied accurately using X-ray
reflectivity (ca. 1{\AA}). We find an electrolyte concentration threshold above
which a substantial additional repulsion is detected in the LiCl films, up to
distances of 100 {\AA}. We interpret this phenomenon as an augmentation of the
Debye screening length, due to the local screening of the condensed hydrophilic
counterions by the primary hydration shell.Comment: 4 pages, 4 figures, to be published Phys. Rev. Let
Spinodal Decomposition in Binary Gases
We carried out three-dimensional simulations, with about 1.4 million
particles, of phase segregation in a low density binary fluid mixture,
described mesoscopically by energy and momentum conserving Boltzmann-Vlasov
equations. Using a combination of Direct Simulation Monte Carlo(DSMC) for the
short range collisions and a version of Particle-In-Cell(PIC) evolution for the
smooth long range interaction, we found dynamical scaling after the ratio of
the interface thickness(whose shape is described approximately by a hyperbolic
tangent profile) to the domain size is less than ~0.1. The scaling length R(t)
grows at late times like t^alpha, with alpha=1 for critical quenches and
alpha=1/3 for off-critical ones. We also measured the variation of temperature,
total particle density and hydrodynamic velocity during the segregation
process.Comment: 11 pages, Revtex, 4 Postscript figures, submitted to PR
Organization of Block Copolymers using NanoImprint Lithography: Comparison of Theory and Experiments
We present NanoImprint lithography experiments and modeling of thin films of
block copolymers (BCP). The NanoImprint lithography is used to align
perpendicularly lamellar phases, over distances much larger than the natural
lamellar periodicity. The modeling relies on self-consistent field calculations
done in two- and three-dimensions. We get a good agreement with the NanoImprint
lithography setups. We find that, at thermodynamical equilibrium, the ordered
BCP lamellae are much better aligned than when the films are deposited on
uniform planar surfaces
Self-Consistent Field study of Polyelectrolyte Brushes
We formulate a self-consistent field theory for polyelectrolyte brushes in
the presence of counterions. We numerically solve the self-consistent field
equations and study the monomer density profile, the distribution of
counterions, and the total charge distribution. We study the scaling relations
for the brush height and compare them to the prediction of other theories. We
find a weak dependence of the brush height on the grafting density.We fit the
counterion distribution outside the brush by the Gouy-Chapman solution for a
virtual charged wall. We calculate the amount of counterions outside the brush
and find that it saturates as the charge of the polyelectrolytes increases
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC
2016 ESC on Acute and Chronic H
Cell tracking in cardiac repair: what to image and how to image
Stem cell therapies hold the great promise and interest for cardiac regeneration among scientists, clinicians and patients. However, advancement and distillation of a standard treatment regimen are not yet finalised. Into this breach step recent developments in the imaging biosciences. Thus far, these technical and protocol refinements have played a critical role not only in the evaluation of the recovery of cardiac function but also in providing important insights into the mechanism of action of stem cells. Molecular imaging, in its many forms, has rapidly become a necessary tool for the validation and optimisation of stem cell engrafting strategies in preclinical studies. These include a suite of radionuclide, magnetic resonance and optical imaging strategies to evaluate non-invasively the fate of transplanted cells. In this review, we highlight the state-of-the-art of the various imaging techniques for cardiac stem cell presenting the strengths and limitations of each approach, with a particular focus on clinical applicability
Molecular dynamics simulations of phase separation in the presence of surfactants
The dynamics of phase separation in two-dimensional binary mixtures diluted by surfactants is studied by means of molecular dynamics simulations. In contrast to pure binary systems, characterized by an algebraic time dependence of the average domain size, we find that systems containing surfactants exhibit nonalgebraic, slow dynamics. The average domain size eventually saturates at a value inversely proportional to the surfactant concentration. We also find that phase separation in systems with different surfactant concentrations follow a crossover scaling form. Finally, although these systems do not fully phase separate, we observe a dynamical scaling which is independent of the surfactant concentration. The results of these simulations are in general in agreement with previous Langevin simulations [Laradji, Guo, Grant, and Zuckermann, J. Phys. A 44, L629 (1991)] and a theory of Ostwald ripening [Yao and Laradji, Phys. Rev. E 47, 2695 (1993)]. © 1994 The American Physical Society
Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).
Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≥1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≤6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)
Improved risk stratification of patients with atrial fibrillation: an integrated GARFIELD-AF tool for the prediction of mortality, stroke and bleed in patients with and without anticoagulation.
OBJECTIVES: To provide an accurate, web-based tool for stratifying patients with atrial fibrillation to facilitate decisions on the potential benefits/risks of anticoagulation, based on mortality, stroke and bleeding risks. DESIGN: The new tool was developed, using stepwise regression, for all and then applied to lower risk patients. C-statistics were compared with CHA2DS2-VASc using 30-fold cross-validation to control for overfitting. External validation was undertaken in an independent dataset, Outcome Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). PARTICIPANTS: Data from 39 898 patients enrolled in the prospective GARFIELD-AF registry provided the basis for deriving and validating an integrated risk tool to predict stroke risk, mortality and bleeding risk. RESULTS: The discriminatory value of the GARFIELD-AF risk model was superior to CHA2DS2-VASc for patients with or without anticoagulation. C-statistics (95% CI) for all-cause mortality, ischaemic stroke/systemic embolism and haemorrhagic stroke/major bleeding (treated patients) were: 0.77 (0.76 to 0.78), 0.69 (0.67 to 0.71) and 0.66 (0.62 to 0.69), respectively, for the GARFIELD-AF risk models, and 0.66 (0.64-0.67), 0.64 (0.61-0.66) and 0.64 (0.61-0.68), respectively, for CHA2DS2-VASc (or HAS-BLED for bleeding). In very low to low risk patients (CHA2DS2-VASc 0 or 1 (men) and 1 or 2 (women)), the CHA2DS2-VASc and HAS-BLED (for bleeding) scores offered weak discriminatory value for mortality, stroke/systemic embolism and major bleeding. C-statistics for the GARFIELD-AF risk tool were 0.69 (0.64 to 0.75), 0.65 (0.56 to 0.73) and 0.60 (0.47 to 0.73) for each end point, respectively, versus 0.50 (0.45 to 0.55), 0.59 (0.50 to 0.67) and 0.55 (0.53 to 0.56) for CHA2DS2-VASc (or HAS-BLED for bleeding). Upon validation in the ORBIT-AF population, C-statistics showed that the GARFIELD-AF risk tool was effective for predicting 1-year all-cause mortality using the full and simplified model for all-cause mortality: C-statistics 0.75 (0.73 to 0.77) and 0.75 (0.73 to 0.77), respectively, and for predicting for any stroke or systemic embolism over 1 year, C-statistics 0.68 (0.62 to 0.74). CONCLUSIONS: Performance of the GARFIELD-AF risk tool was superior to CHA2DS2-VASc in predicting stroke and mortality and superior to HAS-BLED for bleeding, overall and in lower risk patients. The GARFIELD-AF tool has the potential for incorporation in routine electronic systems, and for the first time, permits simultaneous evaluation of ischaemic stroke, mortality and bleeding risks. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier for GARFIELD-AF (NCT01090362) and for ORBIT-AF (NCT01165710)
- …