101 research outputs found
High-resolution MCP-TimePix3 imaging/timing detector for antimatter physics
We present a hybrid imaging/timing detector for force sensitive inertial measurements designed for measurements on positronium, the metastable bound state of an electron and a positron, but also suitable for applications involving other low intensity, low energy beams of neutral (antimatter)-atoms, such as antihydrogen. The performance of the prototype detector was evaluated with a tunable low energy positron beam, resulting in a spatial resolution of approximate t
Development of a detector for inertial sensing of positronium at AEgIS (CERN)
The primary goal of the AEgIS collaboration at CERN is to measure the gravitational acceleration on neutral antimatter. Positronium (Ps), the bound state of an electron and a positron, is a suitable candidate for a force-sensitive inertial measurement by means of deflectometry/interferometry. In order to conduct such an experiment, the impact position and time of arrival of Ps atoms at the detector must be detected simultaneously. The detection of a low-velocity Ps beam with a spatial resolution of (88 ± 5) μm was previously demonstrated [1]. Based on the methodology employed in [1] and [2], a hybrid imaging/timing detector with increased spatial resolution of about 10 μm was developed. The performance of a prototype was tested with a positron beam. The concept of the detector and first results are presented
Control system for ion Penning traps at the AEgIS experiment at CERN
The AEgIS experiment located at the Antiproton Decelerator at CERN aims to measure the gravitational fall of a cold antihydrogen pulsed beam. The precise observation of the antiatoms in the Earth gravitational field requires a controlled production and manipulation of antihydrogen. The neutral antimatter is obtained via a charge exchange reaction between a cold plasma of antiprotons from ELENA decelerator and a pulse of Rydberg positronium atoms. The current custom electronics designed to operate the 5 and 1 T Penning traps are going to be replaced by a control system based on the ARTIQ & Sinara open hardware and software ecosystem. This solution is present in many atomic, molecular and optical physics experiments and devices such as quantum computers. We report the status of the implementation as well as the main features of the new control system
Positronium laser cooling via the - transition with a broadband laser pulse
We report on laser cooling of a large fraction of positronium (Ps) in
free-flight by strongly saturating the - transition with a
broadband, long-pulsed 243 nm alexandrite laser. The ground state Ps cloud is
produced in a magnetic and electric field-free environment. We observe two
different laser-induced effects. The first effect is an increase in the number
of atoms in the ground state after the time Ps has spent in the long-lived
states. The second effect is the one-dimensional Doppler cooling of Ps,
reducing the cloud's temperature from 380(20) K to 170(20) K. We demonstrate a
58(9) % increase in the coldest fraction of the Ps ensemble.Comment: 6 pages, 5 figure
Velocity-selected production of 2S3 metastable positronium
Positronium in the 2 3 S metastable state exhibits a low electrical polarizability and a long lifetime (1140 ns), making it a promising candidate for interferometry experiments with a neutral matter-antimatter system. In the present work, 2 3 S positronium is produced, in the absence of an electric field, via spontaneous radiative decay from the 3 3 P level populated with a 205-nm UV laser pulse. Thanks to the short temporal length of the pulse, 1.5 ns full width at half maximum, different velocity populations of a positronium cloud emitted from a nanochanneled positron-positronium converter were selected by delaying the excitation pulse with respect to the production instant. 2 3 S positronium atoms with velocity tuned between 7
7 10 4 ms 121 and 10
7 10 4 ms 121 were thus produced. Depending on the selected velocity, a 2 3 S production efficiency ranging from 3c0.8% to 3c1.7%, with respect to the total amount of emitted positronium, was obtained. The observed results give a branching ratio for the 3 3 P-2 3 S spontaneous decay of (9.7 \ub1 2.7)%. The present velocity selection technique could allow one to produce an almost monochromatic beam of 3c1
7 10 3 2 3 S atoms with a velocity spread of <10 4 ms 121 and an angular divergence of 3c50 mrad
Hybrid imaging and timing ps laser excitation diagnostics for pulsed antihydrogen production
open48siIn this work we present a hybrid detection method providing simultaneous imaging and timing information suitable for fully monitoring positronium (Ps) formation, its laser excitation, and its spatial propagation for the first trials of pulsed antihydrogen (H) production through a charge-exchange reaction with trapped antiprotons (p). This combined method, based on the synchronous acquisition of an EJ-200 scintillation detector and a microchannel plate (MCP) detector with a dual readout (phosphor screen image and electrical pick-up signal), allows all relevant events in the experiment to be accurately determined in time while allowing high resolution images of e+ from Ps laser photodissociations to be acquired. The timing calibration process of the two detectors discussed in details as well as the future perspectives opened by this method.openCaravita R.; Antonello M.; Belov A.; Bonomi G.; Brusa R.S.; Caccia M.; Camper A.; Castelli F.; Comparat D.; Consolati G.; Demetrio A.; Di Noto L.; Doser M.; Fani M.; Ferragut R.; Gerber S.; Giammarchi M.; Gligorova A.; Gloggler L.T.; Guatieri F.; Haider S.; Hinterberger A.; Khalidova O.; Krasnicky D.; Lagomarsino V.; Malbrunot C.; Mariazzi S.; Matveev V.; Muller S.R.; Nebbia G.; Nedelec P.; Oberthaler M.; Oswald E.; Pagano D.; Penasa L.; Petracek V.; Prelz F.; Rienacker B.; Rohne O.M.; Rotondi A.; Sandaker H.; Santoro R.; Testera G.; Tietje I.; Toso V.; Wolz T.; Zimmer C.; Zurlo N.Caravita, R.; Antonello, M.; Belov, A.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Camper, A.; Castelli, F.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Fani, M.; Ferragut, R.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Gloggler, L. T.; Guatieri, F.; Haider, S.; Hinterberger, A.; Khalidova, O.; Krasnicky, D.; Lagomarsino, V.; Malbrunot, C.; Mariazzi, S.; Matveev, V.; Muller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Oswald, E.; Pagano, D.; Penasa, L.; Petracek, V.; Prelz, F.; Rienacker, B.; Rohne, O. M.; Rotondi, A.; Sandaker, H.; Santoro, R.; Testera, G.; Tietje, I.; Toso, V.; Wolz, T.; Zimmer, C.; Zurlo, N
The AEgIS experiment at CERN: Measuring antihydrogen free-fall in earth's gravitational field to test WEP with antimatter
The AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment is designed with the objective to test the weak equivalence principle with antimatter by studying the free fall of antihydrogen in the Earth's gravitational field. A pulsed cold beam of antihydrogen will be produced by charge exchange between cold Ps excited in Rydberg state and cold antiprotons. Finally the free fall will be measured by a classical moir\ue9 deflectometer. The apparatus being assembled at the Antiproton Decelerator at CERN will be described, then the advancements of the experiment will be reported: positrons and antiprotons trapping measurements, Ps two-step excitation and a test-measurement of antiprotons deflection with a small scale moir\ue9 deflectometer
AEg̅IS latest results
The validity of the Weak Equivalence Principle (WEP) as predicted by General Relativity has been tested up to astounding precision using ordinary matter. The lack hitherto of a stable source of a probe being at the same time electrically neutral, cold and stable enough to be measured has prevented highaccuracy testing of the WEP on anti-matter. The AEg̅IS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment located at CERN's AD (Antiproton Decelerator) facility aims at producing such a probe in the form of a pulsed beam of cold anti-hydrogen, and at measuring by means of a moiré deflectometer the gravitational force that Earth's mass exerts on it. Low temperature and abundance of the H̅ are paramount to attain a high precision measurement. A technique employing a charge-exchange reaction between antiprotons coming from the AD and excited positronium atoms is being developed at AEg̅IS and will be presented hereafter, alongside an overview of the experimental apparatus and the current status of the experimen
Gravity and antimatter: The AEgIS experiment at CERN
open62siFrom the experimental point of view, very little is known about the gravitational interaction between matter and antimatter. In particular, the Weak Equivalence Principle, which is of paramount importance for the General Relativity, has not yet been directly probed with antimatter. The main goal of the AEgIS experiment at CERN is to perform a direct measurement of the gravitational force on antimatter. The idea is to measure the vertical displacement of a beam of cold antihydrogen atoms, traveling in the gravitational field of the Earth, by the means of a moiré deflectometer. An overview of the physics goals of the experiment, of its apparatus and of the first results is presented.openPagano D.; Aghion S.; Amsler C.; Bonomi G.; Brusa R.S.; Caccia M.; Caravita R.; Castelli F.; Cerchiari G.; Comparat D.; Consolati G.; Demetrio A.; Noto L.D.; Doser M.; Evans A.; Fani M.; Ferragut R.; Fesel J.; Fontana A.; Gerber S.; Giammarchi M.; Gligorova A.; Guatieri F.; Haider S.; Hinterberger A.; Holmestad H.; Kellerbauer A.; Khalidova O.; Krasnicky D.; Lagomarsino V.; Lansonneur P.; Lebrun P.; Malbrunot C.; Mariazzi S.; Marton J.; Matveev V.; Mazzotta Z.; Muller S.R.; Nebbia G.; Nedelec P.; Oberthaler M.; Pacifico N.; Penasa L.; Petracek V.; Prelz F.; Prevedelli M.; Ravelli L.; Rienaecker B.; Robert J.; Rohne O.M.; Rotondi A.; Sandaker H.; Santoro R.; Smestad L.; Sorrentino F.; Testera G.; Tietje I.C.; Widmann E.; Yzombard P.; Zimmer C.; Zmeskal J.; Zurlo N.Pagano, D.; Aghion, S.; Amsler, C.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Noto, L. D.; Doser, M.; Evans, A.; Fani, M.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Khalidova, O.; Krasnicky, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Marton, J.; Matveev, V.; Mazzotta, Z.; Muller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Penasa, L.; Petracek, V.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Rienaecker, B.; Robert, J.; Rohne, O. M.; Rotondi, A.; Sandaker, H.; Santoro, R.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N
- …