The International Urban Energy Balance Comparison Project: Initial Results from Phase 2.
Many urban land surface schemes have been developed, incorporating different assumptions about the features of, and processes occurring at, the surface. Here, the first results from Phase 2 of an international comparison are presented. Evaluation is based on analysis of the last 12 months of a 15 month dataset. In general, the schemes have best overall capability to model net all-wave radiation. The models that perform well for one flux do not necessarily perform well for other fluxes. Generally there is better performance for net all wave radiation than sensible heat flux. The degree of complexity included in the models is outlined, and impacts on model performance are discussed in terms of the data made available to modellers at four successive stages
The International Urban Energy Balance Models Comparison Project: First Results from Phase 1
A large number of urban surface energy balance models now exist with different assumptions about the
important features of the surface and exchange processes that need to be incorporated. To date, no com-
parison of these models has been conducted; in contrast, models for natural surfaces have been compared
extensively as part of the Project for Intercomparison of Land-surface Parameterization Schemes. Here, the
methods and first results from an extensive international comparison of 33 models are presented. The aim of
the comparison overall is to understand the complexity required to model energy and water exchanges in
urban areas. The degree of complexity included in the models is outlined and impacts on model performance
are discussed. During the comparison there have been significant developments in the models with resulting
improvements in performance (root-mean-square error falling by up to two-thirds). Evaluation is based on a
dataset containing net all-wave radiation, sensible heat, and latent heat flux observations for an industrial area in
Vancouver, British Columbia, Canada. The aim of the comparison is twofold: to identify those modeling ap-
proaches that minimize the errors in the simulated fluxes of the urban energy balance and to determine the
degree of model complexity required for accurate simulations. There is evidence that some classes of models
perform better for individual fluxes but no model performs best or worst for all fluxes. In general, the simpler
models perform as well as the more complex models based on all statistical measures. Generally the schemes
have best overall capability to model net all-wave radiation and least capability to model latent heat flux
Recommended from our members
Key conclusions of the first international urban land surface model comparison project
he first international urban land surface model comparison was designed to identify three aspects of the urban surface-atmosphere interactions: (1) the dominant physical processes, (2) the level of complexity required to model these, and 3) the parameter requirements for such a model. Offline simulations from 32 land surface schemes, with varying complexity, contributed to the comparison. Model results were analysed within a framework of physical classifications and over four stages. The results show that the following are important urban processes; (i) multiple reflections of shortwave radiation within street canyons, (ii) reduction in the amount of visible sky from within the canyon, which impacts on the net long-wave radiation, iii) the contrast in surface temperatures between building roofs and street canyons, and (iv) evaporation from vegetation. Models that use an appropriate bulk albedo based on multiple solar reflections, represent building roof surfaces separately from street canyons and include a representation of vegetation demonstrate more skill, but require parameter information on the albedo, height of the buildings relative to the width of the streets (height to width ratio), the fraction of building roofs compared to street canyons from a plan view (plan area fraction) and the fraction of the surface that is vegetated. These results, whilst based on a single site and less than 18 months of data, have implications for the future design of urban land surface models, the data that need to be measured in urban observational campaigns, and what needs to be included in initiatives for regional and global parameter databases
Recommended from our members
Investigation of the impact of anthropogenic heat flux within an urban land surface model and PILPS-urban
Results from the first international urban model comparison experiment (PILPS-Urban) suggested that models which neglected the anthropogenic heat flux within the surface energy balance performed at least as well as models that include the source term, but this could not be explained. The analyses undertaken show that the results from PILPS-Urban were masked by the signal from including vegetation, which was identified in PILPS-Urban as being important. Including the anthropogenic heat flux does give improved performance, but the benefit is small for the site studied given the relatively small magnitude of this flux relative to other terms in the surface energy balance. However, there is no further benefit from including temporal variations in the flux at this site. The importance is expected to increase at sites with a larger anthropogenic heat flux and greater temporal variations
Recommended from our members
Modelling the partitioning of turbulent fluxes at urban sites with varying vegetation cover
Inclusion of vegetation is critical for urban land surface models (ULSM) to represent reasonably the turbulent sensible and latent heat flux densities in an urban environment. Here the Joint UK Land Environment Simulator (JULES), an ULSM, is used to simulate the Bowen ratio at a number of urban and rural sites with vegetation cover varying between 1% and 98%. The results show that JULES is able to represent the observed Bowen ratios, but only when the additional anthropogenic water supplied into the urban ecosystem is considered. The impact of the external water use (irrigation, street cleaning), for example, on the surface energy flux partitioning can be as substantial as that of the anthropogenic heat flux on the sensible and latent heat fluxes. The Bowen ratio varies from 1-2 when the plan area vegetation fraction is between 30% and 70%. However, when the vegetation fraction is less than 20%, the Bowen ratios increase substantially (2-10) and have greater sensitivity to assumptions about external water use. As there are few long term observational sites with vegetation cover less than 30%, there is a clear need for more measurement studies in such environments
Recommended from our members
Evaluation of the urban tile in MOSES using surface energy balance observations
The UK Met Office has introduced a new scheme for its urban tile in MOSES 2.2
(Met Office Surface Exchange Scheme version 2.2), which is currently implemented within
the operational Met Office weather forecasting model. Here, the performance of the urban
tile is evaluated in two urban areas: the historic core of downtown Mexico City and a light
industrial site in Vancouver, Canada. The sites differ in terms of building structures and
mean building heights. In both cases vegetation cover is less than 5%. The evaluation is
based on surface energy balance flux measurements conducted at approximately the blend-
ing height, which is the location where the surface scheme passes flux data into the atmo-
spheric model. At both sites, MOSES 2.2 correctly simulates the net radiation, but there are
discrepancies in the partitioning of turbulent and storage heat fluxes between predicted and
observed values. Of the turbulent fluxes, latent heat fluxes were underpredicted by about one
order of magnitude. Multiple model runs revealed MOSES 2.2 to be sensitive to changes in
the canopy heat storage and in the ratio between the aerodynamic roughness length and that
for heat transfer (temperature). Model performance was optimum with heat capacity values
smaller than those generally considered for these sites. The results suggest that the current
scheme is probably too simple, and that improvements may be obtained by increasing the
complexity of the model
Recommended from our members
An urban parameterization for a global climate model. Part I: Formulation and evaluation for two cities
Urbanization, the expansion of built-up areas, is an important yet less-studied aspect of land use/land cover change in climate science. To date, most global climate models used to evaluate effects of land use/land cover change on climate do not include an urban parameterization. Here, the authors describe the formulation and evaluation of a parameterization of urban areas that is incorporated into the Community Land Model, the land surface component of the Community Climate System Model. The model is designed to be simple enough to be compatible with structural and computational constraints of a land surface model coupled to a global climate model yet complex enough to explore physically based processes known to be important in determining urban climatology. The city representation is based upon the “urban canyon” concept, which consists of roofs, sunlit and shaded walls, and canyon floor. The canyon floor is divided into pervious (e.g., residential lawns, parks) and impervious (e.g., roads, parking lots, sidewalks) fractions. Trapping of longwave radiation by canyon surfaces and solar radiation absorption and reflection is determined by accounting for multiple reflections. Separate energy balances and surface temperatures are determined for each canyon facet. A one-dimensional heat conduction equation is solved numerically for a 10-layer column to determine conduction fluxes into and out of canyon surfaces. Model performance is evaluated against measured fluxes and temperatures from two urban sites. Results indicate the model does a reasonable job of simulating the energy balance of cities
Recommended from our members
Interpretation of particle number size distributions measured across an urban area during the FASTER campaign
Abstract. Particle number size distributions have been measured simultaneously by scanning mobility particle sizers (SMPSs) at five sites in central London for a 1 month campaign in January–February 2017. These measurements were accompanied by condensation particle counters (CPCs) to measure total particle number count at four of the sites and Aethalometersmeasuringblackcarbon(BC)atfivesites.The spatialdistributionandinter-relationshipsoftheparticlesize distribution and SMPS total number counts with CPC total number counts and black carbon measurements have been analysed in detail as well as variations in the size distributions. One site (Marylebone Road) was in a street canyon with heavy traffic, one site (Westminster University) was on a rooftop adjacent to the Marylebone Road sampler, and a further sampler was located at Regent’s University within a major park to the north of Marylebone Road. A fourth sampler was located nearby at 160m above ground level on the BT tower and a fifth sampler was located 4km to the west of the main sampling region at North Kensington. Consistent with earlier studies it was found that the mode in the size distribution had shifted to smaller sizes at the Regent’s University (park) site, the mean particle shrinkage rate being 0.04nms−1 with slightly lower values at low wind speeds and some larger values at higher wind speeds. There was evidence of complete evaporation of the semi-volatile nucleation mode under certain conditions at the elevated BT Tower site. While the SMPS total count and black carbon showed typical traffic-dominated diurnal profiles, the
CPC count data typically peaked during night-time as did CPC/SMPS and CPC/BC ratios. This is thought to be due to the presence of high concentrations of small particles (2.5–15nm diameter) probably arising from condensational growth from traffic emissions during the cooler night-time conditions. Such behaviour was most marked at the Regent’s University and Westminster University sites and less so at Marylebone Road, while at the elevated BT Tower site the ratio of particle number(CPC) to black carbon peaked during the morning rush hour and not at night-time, unlike the other sites. An elevation in nucleation mode particles associated with winds from the west and WSW sector was concluded to result from emissions from London Heathrow Airport, despite a distance of 22km from the central London sites
Recommended from our members
A low-cost wireless temperature sensor: evaluation for use in environmental applications
With a wide range of applications benefiting from dense network air temperature observations but with limitations of costs, existing siting guidelines and risk of damage to sensors, new methods are required to gain a high resolution understanding of the spatio-temporal patterns of urban meteorological phenomena such as the urban heat island or precision farming needs. With the launch of a new generation of low cost sensors it is possible to deploy a network to monitor air temperature at finer spatial resolutions. Here we investigate the Aginova Sentinel Micro (ASM) sensor with a bespoke radiation shield (together < US$150) which can provide secure near-real-time air temperature data to a server utilising existing (or user deployed) Wireless Fidelity (Wi-Fi) networks. This makes it ideally suited for deployment where wireless communications readily exist, notably urban areas. Assessment of the performance of the ASM relative to traceable standards in a water bath and atmospheric chamber show it to have good measurement accuracy with mean errors < ± 0.22 °C between -25 and 30 °C, with a time constant in ambient air of 110 ± 15 s. Subsequent field tests of it within the bespoke shield also had excellent performance (root-mean-square error = 0.13 °C) over a range of meteorological conditions relative to a traceable operational UK Met Office platinum resistance thermometer. These results indicate that the ASM and bespoke shield are more than fit-for-purpose for dense network deployment in urban areas at relatively low cost compared to existing observation techniques
Recommended from our members
Development of the Surface Urban Energy and Water balance Scheme (SUEWS) for cold climate cities
The Surface Urban Energy and Water Balance Scheme (SUEWS) is developed to include snow. The processes addressed include accumulation of snow on the different urban surface types: snow albedo and density aging, snow melting and re-freezing of meltwater. Individual model parameters are assessed and independently evaluated using long-term observations in the two cold climate cities of Helsinki and Montreal. Eddy covariance sensible and latent heat fluxes and snow depth observations are available for two sites in Montreal and one in Helsinki. Surface runoff from two catchments (24 and 45 ha) in Helsinki and snow properties (albedo and density) from two sites in Montreal are also analysed. As multiple observation sites with different land-cover characteristics are available in both cities, model development is conducted independent of evaluation.
The developed model simulates snowmelt related runoff well (within 19% and 3% for the two catchments in Helsinki when there is snow on the ground), with the springtime peak estimated correctly. However, the observed runoff peaks tend to be smoother than the simulated ones, likely due to the water holding capacity of the catchments and the missing time lag between the catchment and the observation point in the model. For all three sites the model simulates the timing of the snow accumulation and melt events well, but underestimates the total snow depth by 18–20% in Helsinki and 29–33% in Montreal. The model is able to reproduce the diurnal pattern of net radiation and turbulent fluxes of sensible and latent heat during cold snow, melting snow and snow-free periods. The largest model uncertainties are related to the timing of the melting period and the parameterization of the snowmelt. The results show that the enhanced model can simulate correctly the exchange of energy and water in cold climate cities at sites with varying surface cover
- …