507 research outputs found
Clinical, genetic, neurophysiological and functional study of new mutations in episodic ataxia type 1.
Heterozygous mutations in KCNA1 cause episodic ataxia type 1 (EA1), an ion channel disorder characterised by brief paroxysms of cerebellar dysfunction and persistent neuromyotonia. This paper describes four previously unreported families with EA1, with the aim of understanding the phenotypic spectrum associated with different mutations
Using an e-Health Intervention to Reduce Prolonged Sitting in UK Office Workers: A Randomised Acceptability and Feasibility Study
Low-cost workplace interventions are required to reduce prolonged sitting in office workers as this may improve employees’ health and well-being. This study aimed to assess the acceptability and feasibility of an e-health intervention to reduce prolonged sitting among sedentary UK-based office workers. Secondary aims were to describe preliminary changes in employee health, mood and work productivity after using an e-health intervention. Healthy, university office workers (n = 14) completed this study. An 8 week randomised crossover design was used, consisting of two trials: Intervention (computer-based prompts) and Control. Eligibility and retention rates were recorded to assess the feasibility of the trial and interviews were conducted following the intervention to explore its acceptability. Sitting, standing and stepping were objectively assessed prior to and during week 8 of each trial. Before and after each trial, measurements of vascular function, cerebrovascular function, mood and work productivity were obtained. This study had eligibility and retention rates of 54.5% and 77.8%, respectively. Participants expressed a lack of autonomy and disruption to their workflow when using the e-health intervention, raising concerns over its acceptability and long-term implementation. Preliminary data indicate that the intervention may improve the patterning of activity accrued during work hours, with increases in the number of standing and stepping bouts completed, in addition to improving vascular function. This e-health intervention is feasible to deliver in a cohort of university office workers. However, adaptations to its implementation, such as personalised settings, are needed to increase acceptability before larger trials can be conducted
Dual mobility versus conventional total hip arthroplasty in femoral neck fractures (DISTINCT): protocol for a registry-nested, open-label, cluster-randomised crossover trial
Introduction Hip fractures treated with total hip arthroplasty (THA) are at high risk of prosthesis instability, and dislocation is the most common indication for revision surgery. This study aims to determine whether dual mobility THA implants reduce the risk of dislocation compared with conventional THA in patients with hip fracture suitable to be treated with THA. Methods and analysis This is a cluster-randomised, crossover, open-label trial nested within the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). The clusters will comprise hospitals that perform at least 12 THAs for hip fracture per annum. All adults age ≥50 years who meet the Australian and New Zealand Hip Fracture Registry guidelines for THA will be included. The intervention will be dual mobility THA and the comparator will be conventional THA. Each hospital will be allocated to two consecutive periods, one of dual mobility THA and the other of conventional THA in random order, aiming for an average of 16 patients eligible for the primary analysis per group (32 total per site), allowing different recruitment totals between sites. Data will be collected through the AOANJRR and linked with patient-level discharge data acquired through government agencies. The primary outcome is dislocation within 1 year. Secondary outcomes include revision surgery for dislocation and all-cause, complications and mortality at 1, 2 and 5 years. If dual mobility THA is found to be superior, a cost-effectiveness analysis will be conducted. The study will aim to recruit 1536 patients from at least 48 hospitals over 3 years. Ethics and dissemination Ethics approval has been granted (Sydney Local Health District - Royal Prince Alfred Hospital Zone (approval X20-0162 and 2020/ETH00680) and site-specific approvals). Participant recruitment is via an opt-out consent process as both treatments are considered accepted, standard practice. The trial is endorsed by the Australia and New Zealand Musculoskeletal Clinical Trials Network. Trial registration number ACTRN12621000069853
Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature
Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components
Genetic Diversity and Antimicrobial Resistance of Escherichia coli from Human and Animal Sources Uncovers Multiple Resistances from Human Sources
Escherichia coli are widely used as indicators of fecal contamination, and in some cases to identify host sources of fecal contamination in surface water. Prevalence, genetic diversity and antimicrobial susceptibility were determined for 600 generic E. coli isolates obtained from surface water and sediment from creeks and channels along the middle Santa Ana River (MSAR) watershed of southern California, USA, after a 12 month study. Evaluation of E. coli populations along the creeks and channels showed that E. coli were more prevalent in sediment compared to surface water. E. coli populations were not significantly different (P = 0.05) between urban runoff sources and agricultural sources, however, E. coli genotypes determined by pulsed-field gel electrophoresis (PFGE) were less diverse in the agricultural sources than in urban runoff sources. PFGE also showed that E. coli populations in surface water were more diverse than in the sediment, suggesting isolates in sediment may be dominated by clonal populations.Twenty four percent (144 isolates) of the 600 isolates exhibited resistance to more than one antimicrobial agent. Most multiple resistances were associated with inputs from urban runoff and involved the antimicrobials rifampicin, tetracycline, and erythromycin. The occurrence of a greater number of E. coli with multiple antibiotic resistances from urban runoff sources than agricultural sources in this watershed provides useful evidence in planning strategies for water quality management and public health protection
Joint registry approach for identification of outlier prostheses
Background and purposeJoint Replacement Registries play a significant role in monitoring arthroplasty outcomes by publishing data on survivorship of individual prostheses or combinations of prostheses. The difference in outcomes can be device- or non-device-related, and these factors can be analyzed separately. Although registry data indicate that most prostheses have similar outcomes, some have a higher than anticipated rate of revision when compared to all other prostheses in their class. This report outlines how the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has developed a method to report prostheses with a higher than expected rate of revision. These are referred to as "outlier" prostheses.Material and methodsSince 2004, the AOANJRR has developed a standardized process for identifying outliers. This is based on a 3-stage process consisting of an automated algorithm, an extensive analysis of individual prostheses or combinations by registry staff, and finally a meeting involving a panel from the Australian Orthopaedic Association Arthroplasty Society. Outlier prostheses are listed in the Annual Report as (1) identified but no longer used in Australia, (2) those that have been re-identified and that are still used, and (3) those that are being identified for the first time.Results78 prostheses or prosthesis combinations have been identified as being outliers using this approach (AOANJRR 2011 Annual Report). In addition, 5 conventional hip prostheses were initially identified, but after further analysis no longer met the defined criteria. 1 resurfacing hip prosthesis was initially identified, subsequently removed from the list, and then re-identified the following year when further data were available. All unicompartmental and primary total knee prostheses identified as having a higher than expected rate of revision have continued to be re-identified.InterpretationIt is important that registries use a transparent and accountable process to identify an outlier prosthesis. This paper describes the development, implementation, assessment, and impact of the approach used by the Australian Registry.Richard N de Steiger, Lisa N Miller, David C Davidson, Philip Ryan and Stephen E Grave
Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008: A report from the Norwegian Arthroplasty Register
Background and purpose: Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods: Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results: Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0– 97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation: With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation
The effectiveness of public health interventions to reduce the health impact of climate change:a systematic review of systematic reviews
Climate change is likely to be one of the most important threats to public health in the coming years. Yet despite the large number of papers considering the health impact of climate change, few have considered what public health interventions may be of most value in reducing the disease burden. We aimed to evaluate the effectiveness of public health interventions to reduce the disease burden of high priority climate sensitive diseases
Patellar tendon enthesis abnormalities and their association with knee pain and structural abnormalities in older adults
Objective: To describe associations between presence of patellar tendon enthesis (PTE) abnormalities and symptoms, structural abnormalities, and total knee replacement (TKR) in older adult cohort.Methods: PTE abnormalities (presence of abnormal bone signal and/or bone erosion), were measured on T2-weighted magnetic resonance (MR) images at baseline in 961 community-dwelling older adults. Knee pain and function limitation were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Bone marrow lesions (BMLs), cartilage volume and defects score, and infrapatellar fat pad (IPFP) area were measured using validated methods. Incidence of TKR was determined by data linkage.Results: Participants with abnormal PTE bone signal and/or erosion was 20%. Cross-sectionally, presence of PTE abnormalities was associated with greater pain intensity while going up and down stairs (β = 0.22 (95% confidence interval (CI); 0.03, 0.41)), greater risk of femoral BMLs (RR = 1.46 (1.12, 1.90)) and worse tibial cartilage defects score (RR = 1.70 (1.16, 2.47), and smaller IPFP area (β = -0.27 (-0.47, -0.06) cm2), after adjustment of confounders. Longitudinally, presence of baseline PTE abnormalities was associated with a deleterious increase in tibial BML size (RR = 1.52 (1.12, 2.05)) over 10.7 years but not symptoms, other structural changes, or TKR.Conclusion: PTE abnormalities are common in older adults. Presence of cross-sectional but not longitudinal associations suggests they are commonly co-exist with other knee structural abnormalities but may not play a major role in symptom development or structural change, excepting tibial BMLs
- …