185 research outputs found

    Localized magnetoplasmon modes arising from broken translational symmetry in semiconductor superlattices

    Full text link
    The electromagnetic propagator associated with the localized collective magnetoplasmon excitations in a semiconductor superlattice with broken translational symmetry, is calculated analytically within linear response theory. We discuss the properties of these collective excitations in both radiative and non-radiative regimes of the electromagnetic spectra. We find that low frequency retarded modes arise when the surface density of carriers at the symmetry breaking layer is lower than the density at the remaining layers. Otherwise a doublet of localized, high-frequency magnetoplasmon-like modes occurs.Comment: Revtex file + separate pdf figure

    Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries

    Get PDF
    Background: The first commercially available bioresorbable scaffold (BRS) had a strut thickness of 156 microns. As such, it had the potential for delivery challenges and higher thrombogenicity. The aim herein, is to evaluate biomechanical performance, pharmacokinetics and vascular healing of a novel thin strut (100 μm) sirolimus eluting BRS (MeRes-100, Meril Life Sciences, Gujarat, India) against the once clinically used BRS (Absorb BVS, Abbott, Santa Clara, CA) in porcine coronary arteries. Methods: Following device implantation, angiographic and optical coherence tomography (OCT) evaluation were performed at 45, 90, 180 days, 1 year and 2 years. Histological evaluation was per­formed at 30, 90 and 180 days. Results: At 2 years, both lumen (MeRes-100 7.07 ± 1.82 mm2 vs. Absorb BVS 7.57 ± 1.39 mm2, p = NS) and scaffold areas (MeRes-100 9.73 ± 1.80 mm2 vs. Absorb BVS 9.67 ± 1.25 mm2, p = NS) were comparable between tested and control scaffolds. Also, the late lumen area gain at 2 years was similar in both groups tested (MeRes-100 1.03 ± 1.98 mm2 vs. Absorb BVS 0.85 ± 1.56 mm2, p = NS). Histologic examination up to 6 months showed comparable healing and inflammation profiles for both devices. Conclusions: The novel sirolimus-eluting BRS with thinner struts and hybrid cell design showed similar biomechanical durability and equivalent inhibition of neointimal proliferation when compared to the first-ever Absorb BVS up to 2 years in normal porcine coronary arteries

    Off-pump epicardial ventricular reconstruction restores left ventricular twist and reverses remodeling in an ovine anteroapical aneurysm model

    Get PDF
    ObjectiveThe loss of normal apical rotation is associated with left ventricular (LV) remodeling and systolic dysfunction in patients with congestive heart failure after myocardial infarction. The objective of the present study was to evaluate the effect of epicardial ventricular reconstruction, an off-pump, less-invasive surgical reshaping technique, on myocardial strain, LV twist, and the potential alteration of myocardial fiber orientation in an ovine model of LV anteroapical aneurysm.MethodsLV anteroapical myocardial infarction was induced by coil embolization of the left anterior descending artery. Eight weeks after occlusion, epicardial ventricular reconstruction was performed using left thoracotomy under fluoroscopic guidance in 8 sheep to completely exclude the scar. The peak systolic longitudinal/circumferential strains and LV twist were evaluated using speckle tracking echocardiography before (baseline), after device implantation, and at 6 weeks of follow-up.ResultsEpicardial ventricular reconstruction was completed in all sheep without any complications. Immediately after device implantation, LV twist significantly increased (4.18 ± 1.40 vs baseline 1.97 ± 1.92; P = .02). The ejection fraction had increased 17% and LV end-systolic volume had decreased 40%. The global longitudinal strain increased from −5.3% to −9.1% (P < .05). Circumferential strain increased in both middle and apical LV segments, with the greatest improvement in the inferior lateral wall (from −11.4% to −20.6%, P < .001). These effects were maintained ≥6 weeks after device implantation without redilation.ConclusionsLess invasive than alternative therapies, epicardial ventricular reconstruction on the off-pump beating heart can restore LV twist and systolic strain and reverse LV remodeling in an ovine anteroapical aneurysm model

    Anticoagulation in Patients With COVID-19: JACC Review Topic of the Week.

    Get PDF
    Clinical, laboratory, and autopsy findings support an association between coronavirus disease-2019 (COVID-19) and thromboembolic disease. Acute COVID-19 infection is characterized by mononuclear cell reactivity and pan-endothelialitis, contributing to a high incidence of thrombosis in large and small blood vessels, both arterial and venous. Observational studies and randomized trials have investigated whether full-dose anticoagulation may improve outcomes compared with prophylactic dose heparin. Although no benefit for therapeutic heparin has been found in patients who are critically ill hospitalized with COVID-19, some studies support a possible role for therapeutic anticoagulation in patients not yet requiring intensive care unit support. We summarize the pathology, rationale, and current evidence for use of anticoagulation in patients with COVID-19 and describe the main design elements of the ongoing FREEDOM COVID-19 Anticoagulation trial, in which 3,600 hospitalized patients with COVID-19 not requiring intensive care unit level of care are being randomized to prophylactic-dose enoxaparin vs therapeutic-dose enoxaparin vs therapeutic-dose apixaban. (FREEDOM COVID-19 Anticoagulation Strategy [FREEDOM COVID]; NCT04512079).Dr Farkouh has received research grants from Amgen, Novo Nordisk, and Novartis. Dr Stone has received speaker honoraria from Infraredx; has served as a consultant to Valfix, TherOx, Robocath, HeartFlow, Ablative Solutions, Miracor, Neovasc, Abiomed, Ancora, Vectorious, Elucid Bio, Occlutech, CorFlow, Apollo Therapeutics, Impulse Dynamics, Cardiomech, Gore, and Amgen; and has equity/ options from Ancora, Cagent, Applied Therapeutics, Biostar family of funds, SpectraWave, Orchestra Biomed, Aria, Cardiac Success, Valfix, and Xenter. Dr Godoy is supported by the Frederick Banting and Charles Best Canada Graduate Scholarship (Doctoral Research Award) from the Canadian Institutes of Health Research. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.S

    Isolation of pulmonary veins using a thermoreactive implantable device with external energy transfer : evaluation in a porcine model

    No full text
    Background: Pulmonary vein isolation (PVI) is a well-established method for the treatment of symptomatic paroxysmal atrial fibrillation, but is only partly successful with a high rate of electrical reconnection. We introduce a novel technique in which PVI is accomplished by noninvasive heating of a dedicated thermoresponse implant inserted into the pulmonary veins (PV), demonstrated in a porcine model. Methods: A self-expanding nitinol-based implant was positioned in the common inferior PV of 11 pigs, using a fluoroscopy-guided transatrial appendage approach. Ablation was performed through contactless energy transfer from a primary extracorporal coil to a secondary heat ring (HR) embedded in the proximal part of the implant. Electrophysiological conduction was assessed prior to and postablation, and at 3 months. Histological samples were obtained acutely (n=4) and after 3 months (n=7). Results: In total, 13 PV implants were successfully positioned in the inferior PVs of 11 animals. Ablation was performed without injury of adjacent structures. PVI and bidirectional block was electrophysiologically confirmed in all cases immediately at the time of implantation and 3 months later in seven chronic animals in whom testing was repeated. Marked evidence of ablation around the proximal HR was evident at 3 months postprocedure, with scar tissue formation and only mild neointimal proliferation. Conclusions: Successful PVI can be obtained by external electromagnetic heat transfer to a novel pulmonary vein implant

    Human Exposure to Endocrine-Disrupting Chemicals and Prenatal Risk Factors for Cryptorchidism and Hypospadias: A Nested Case–Control Study

    Get PDF
    BACKGROUND: Exposure to xenoestrogens during pregnancy may disturb the development and function of male sexual organs. OBJECTIVE: In this study we aimed to determine whether the combined effect of environmental estrogens measured as total effective xenoestrogen burden (TEXB) is a risk factor for male urogenital malformations. METHODS: In a case-control study, nested in a mother-child cohort (n = 702) established at Granada University Hospital, we compared 50 newborns with diagnosis of cryptorchidism and/or hypospadias with 114 boys without malformations matched by gestational age, date of birth, and parity. Controls did not differ from the total cohort in confounding variables. TEXB and levels of 16 organochlorine pesticides were measured in placenta tissues. Characteristics of parents, pregnancy, and birth were gathered by questionnaire. We used conditional and unconditional regression models to estimate odds ratios (ORs) and 95% confidence intervals (CIs). RESULTS: TEXB from organohalogenated compounds was detectable in 72% and 54% of case and control placentas, respectively. Compared with controls, cases had an OR for detectable versus non-detectable TEXB of 2.82 (95% CI, 1.10-7.24). More pesticides were detected in cases than in controls (9.34 +/- 3.19 vs. 6.97 +/- 3.93). ORs for cases with detectable levels of pesticides, after adjusting for potential confounders in the conditional regression analysis, were o,p'-DDT (OR = 2.25; 95% CI, 1.03-4.89), p,p'-DDT (OR = 2.63; 95% CI, 1.21-5.72), lindane (OR = 3.38; 95% CI, 1.36-8.38), mirex (OR = 2.85; 95% CI, 1.22-6.66), and endosulfan alpha (OR = 2.19; 95% CI, 0.99-4.82). Engagement of mothers in agriculture (OR = 3.47; 95% CI, 1.33-9.03), fathers' occupational exposure to xenoestrogens (OR = 2.98; 95% CI, 1.11-8.01), and history of previous stillbirths (OR = 4.20; 95% CI, 1.11-16.66) were also associated with risk of malformations. CONCLUSIONS: We found an increased risk for male urogenital malformations related to the combined effect of environmental estrogens in placenta

    Optimizing flushing parameters in intracoronary optical coherence tomography: an in vivo swine study

    Get PDF
    Intracoronary optical frequency domain imaging (OFDI), requires the displacement of blood for clear visualization of the artery wall. Radiographic contrast agents are highly effective at displacing blood however, may increase the risk of contrast-induced nephropathy. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. The aim of this work was to determine the optimal flushing parameters necessary to reliably perform intracoronary OFDI while reducing the volume of administered radiographic contrast, and assess the influence of flushing media choice on vessel wall measurements. 144 OFDI pullbacks were acquired together with synchronized EKG and intracoronary pressure wire recordings in three swine. OFDI images were graded on diagnostic quality and quantitative comparisons of flushing efficiency and intracoronary cross-sectional area with and without precise refractive index calibration were performed. Flushing media with higher viscosities resulted in rapid and efficient blood displacement. Media with lower viscosities resulted in increased blood-media transition zones, reducing the pullback length of diagnostic quality images obtained. Flushing efficiency was found to increase with increases in flow rate and duration. Calculations of lumen area using different flushing media were significantly different, varying up to 23 % (p < 0.0001). This error was eliminated with careful refractive index calibration. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. For patients with sensitivity to contrast, to reduce the risk of contrast induced nephrotoxicity we recommend that intracoronary OFDI be conducted with flushing solutions containing little or no radiographic contrast. In addition, our findings show that careful refractive index compensation should be performed, taking into account the specific contrast agent used, in order to obtain accurate intravascular OFDI measurements.Merck & Co., Inc.National Institutes of Health (U.S.) (Grant Numbers R00CA134920, R01HL076398, R01HL093717

    Pandemic and post-pandemic Influenza A (H1N1) infection in critically ill patients

    Get PDF
    Background: There is a vast amount of information published regarding the impact of 2009 pandemic Influenza A (pH1N1) virus infection. However, a comparison of risk factors and outcome during the 2010-2011 post-pandemic period has not been described. Methods: A prospective, observational, multi-center study was carried out to evaluate the clinical characteristics and demographics of patients with positive RT-PCR for H1N1 admitted to 148 Spanish intensive care units (ICUs). Data were obtained from the 2009 pandemic and compared to the 2010-2011 post-pandemic period. Results: Nine hundred and ninety-seven patients with confirmed An/H1N1 infection were included. Six hundred and forty-eight patients affected by 2009 (pH1N1) virus infection and 349 patients affected by the post-pandemic Influenza (H1N1)v infection period were analyzed. Patients during the post-pandemic period were older, had more chronic comorbid conditions and presented with higher severity scores (Acute Physiology And Chronic Health Evaluation II (APACHE II) and Sequential Organ Failure Assessment (SOFA)) on ICU admission. Patients from the post-pandemic Influenza (H1N1)v infection period received empiric antiviral treatment less frequently and with delayed administration. Mortality was significantly higher in the post-pandemic period. Multivariate analysis confirmed that haematological disease, invasive mechanical ventilation and continuous renal replacement therapy were factors independently associated with worse outcome in the two periods. HIV was the only new variable independently associated with higher ICU mortality during the post-pandemic Influenza (H1N1)v infection period. Conclusion: Patients from the post-pandemic Influenza (H1N1)v infection period had an unexpectedly higher mortality rate and showed a trend towards affecting a more vulnerable population, in keeping with more typical seasonal viral infection
    corecore