71 research outputs found

    Preference, satisfaction and errors with two dry powder inhalers in patients with COPD

    No full text
    Objective: To assess preference, satisfaction and critical errors with a novel, breath-actuated, multi-dose dry powder inhaler (DPI; Genuair®/Pressair™), versus a widely used, single-dose DPI (HandiHaler®) in patients with moderate-to-severe chronic obstructive pulmonary disease. Methods: In this randomised, open-label, multicentre, cross-over study, patients (aged ≥ 40 years) inhaled placebo once daily through both inhalers for 2 weeks in addition to current medication. The primary end point was percentage of patients who preferred Genuair to HandiHaler. Overall patient satisfaction (5-point scale: 1 = very dissatisfied; 5 = very satisfied), critical errors and willingness to continue using each inhaler (0 = not willing; 100 = definitely willing) were assessed. Results: Of 130 patients randomised, 105 were included in the intent-to-treat population (71.4% male; mean age 65.7 years). After 2 weeks, significantly more patients preferred Genuair than HandiHaler (79.1 vs 20.9%; p < 0.0001). Overall satisfaction scores (4.6 vs 3.8; p < 0.0001) and willingness to continue use scores (84.0 vs 62.5; p < 0.0001) were significantly higher with Genuair versus HandiHaler. Significantly fewer patients made ≥ 1 critical error with Genuair only compared with HandiHaler only (2.9 vs 19.0%; p < 0.0001). Conclusion: After 2 weeks' practice, patients preferred and were more willing to continue using Genuair than HandiHaler. Genuair was associated with higher patient satisfaction and fewer critical errors than HandiHaler Read More: http://informahealthcare.com/doi/abs/10.1517/17425247.2013.80818

    A randomised open-label cross-over study of inhaler errors, preference and time to achieve correct inhaler use in patients with COPD or asthma: Comparison of ELLIPTA with other inhaler devices

    Get PDF
    Errors in the use of different inhalers were investigated in patients naive to the devices under investigation in a multicentre, single-visit, randomised, open-label, cross-over study. Patients with chronic obstructive pulmonary disease (COPD) or asthma were assigned to ELLIPTA vs DISKUS (Accuhaler), metered-dose inhaler (MDI) or Turbuhaler. Patients with COPD were also assigned to ELLIPTA vs Handihaler or Breezhaler. Patients demonstrated inhaler use after reading the patient information leaflet (PIL). A trained investigator assessed critical errors (i.e., those likely to result in the inhalation of significantly reduced, minimal or no medication). If the patient made errors, the investigator demonstrated the correct use of the inhaler, and the patient demonstrated inhaler use again. Fewer COPD patients made critical errors with ELLIPTA after reading the PIL vs: DISKUS, 9/171 (5%) vs 75/171 (44%); MDI, 10/80 (13%) vs 48/80 (60%); Turbuhaler, 8/100 (8%) vs 44/100 (44%); Handihaler, 17/118 (14%) vs 57/118 (48%); Breezhaler, 13/98 (13%) vs 45/98 (46%; all P<0.001). Most patients (57-70%) made no errors using ELLIPTA and did not require investigator instruction. Instruction was required for DISKUS (65%), MDI (85%), Turbuhaler (71%), Handihaler (62%) and Breezhaler (56%). Fewer asthma patients made critical errors with ELLIPTA after reading the PIL vs: DISKUS (3/70 (4%) vs 9/70 (13%), P=0.221); MDI (2/32 (6%) vs 8/32 (25%), P=0.074) and significantly fewer vs Turbuhaler (3/60 (5%) vs 20/60 (33%), P<0.001). More asthma and COPD patients preferred ELLIPTA over the other devices (all P≤0.002). Significantly, fewer COPD patients using ELLIPTA made critical errors after reading the PIL vs other inhalers. More asthma and COPD patients preferred ELLIPTA over comparator inhalers
    • …
    corecore