596 research outputs found
Functional characterization of orbicularis oculi and extraocular muscles
The orbicularis oculi are the sphincter muscles of the eyelids and are involved in modulating facial expression. They differ from both limb and extraocular muscles (EOMs) in their histology and biochemistry. Weakness of the orbicularis oculi muscles is a feature of neuromuscular disorders affecting the neuromuscular junction, and weakness of facial muscles and ptosis have also been described in patients with mutations in the ryanodine receptor gene. Here, we investigate human orbicularis oculi muscles and find that they are functionally more similar to quadriceps than to EOMs in terms of excitation-contraction coupling components. In particular, they do not express the cardiac isoform of the dihydropyridine receptor, which we find to be highly expressed in EOMs where it is likely responsible for the large depolarization-induced calcium influx. We further show that human orbicularis oculi and EOMs express high levels of utrophin and low levels of dystrophin, whereas quadriceps express dystrophin and low levels of utrophin. The results of this study highlight the notion that myotubes obtained by explanting satellite cells from different muscles are not functionally identical and retain the physiological characteristics of their muscle of origin. Furthermore, our results indicate that sparing of facial and EOMs in patients with Duchenne muscular dystrophy is the result of the higher levels of utrophin expression
Environmental Estrogens Induce Mast Cell Degranulation and Enhance IgE-Mediated Release of Allergic Mediators
BACKGROUND: Prevalence and morbidity of allergic diseases have increased over the last decades. Based on the recently recognized differences in asthma prevalence between the sexes, we have examined the effect of endogenous estrogens on a key element of the allergic response. Some lipophilic pollutants have estrogen-like activities and are termed environmental estrogens. These pollutants tend to degrade slowly in the environment and to bioaccumulate and bioconcentrate in the food chain; they also have long biological half-lives. OBJECTIVES: Our goal in this study was to identify possible pathogenic roles for environmental estrogens in the development of allergic diseases. METHODS: We screened a number of environmental estrogens for their ability to modulate the release of allergic mediators from mast cells. We incubated a human mast cell line and primary mast cell cultures derived from bone marrow of wild type and estrogen receptor α (ER-α )âdeficient mice with environmental estrogens with and without estradiol or IgE and allergens. We assessed degranulation of mast cells by quantifying the release of ÎČ -hexosaminidase. RESULTS: All of the environmental estrogens tested caused rapid, dose-related release of ÎČ -hexosaminidase from mast cells and enhanced IgE-mediated release. The combination of physiologic concentrations of 17ÎČ -estradiol and several concentrations of environmental estrogens had additive effects on mast cell degranulation. Comparison of bone marrow mast cells from ER-α âsufficient and ER-α âdeficient mice indicated that much of the effect of environmental estrogens was mediated by ER-α . CONCLUSIONS: Our findings suggest that estrogenic environmental pollutants might promote allergic diseases by inducing and enhancing mast cell degranulation by physiologic estrogens and exposure to allergens
Measurement of Proton Light Yield of Water-based Liquid Scintillator
The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast neutrons from inverse ÎČ-decay coincidence signals. This work presents the first measurement of the proton light yield of a water-based liquid scintillator (WbLS) formulated from 5% linear alkyl benzene (LAB), at energies below 20 MeV, as well as a measurement of the proton light yield of a pure LAB + 2 g/L 2,5-diphenyloxazole (PPO) mixture (LABPPO). The measurements were performed using a double time-of-flight method and a pulsed neutron beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The proton light yields were measured relative to that of a 477 keV electron. The relative proton light yield of WbLS was approximately 3.8% lower than that of LABPPO, itself exhibiting a relative proton light yield 15â20% higher than previous measurements of an analogous anoxic sample. The observed quenching is not compatible with the Birks model for either material, but is well described with the addition of Chouâs bimolecular quenching term. © 2023, The Author(s)
Measurement of proton light yield of water-based liquid scintillator
The proton light yield of liquid scintillators is an important property in
the context of their use in large-scale neutrino experiments, with direct
implications for neutrino-proton scattering measurements and the discrimination
of fast neutrons from inverse beta-decay coincidence signals. This work
presents the first measurement of the proton light yield of a water-based
liquid scintillator (WbLS) formulated from 5% linear alkyl benzene (LAB), at
energies below 20 MeV, as well as a measurement of the proton light yield of a
pure LAB + 2 g/L 2,5-diphenyloxazole (PPO) mixture (LABPPO). The measurements
were performed using a double time-of-flight method and a pulsed neutron beam
from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The proton
light yields were measured relative to that of a 477 keV electron. The relative
proton light yield of WbLS was approximately 3.8% lower than that of LABPPO,
itself exhibiting a relative proton light yield higher than previous
measurements of an analogous anoxic sample. The observed quenching is not
compatible with the Birks model for either material, but is well described with
the addition of Chou's bimolecular quenching term.Comment: 14 pages, 11 figure
Comparison of the ICareÂź rebound tonometer with the Goldmann tonometer in a normal population
The aim of this study was to evaluate the accuracy of measurement of intraocular pressure (IOP) using a new induction/impact rebound tonometer (ICare) in comparison with the Goldmann applanation tonometer (AT). The left eyes of 46 university students were assessed with the two tonometers, with induction tonometry being performed first. The ICare was handled by an optometrist and the Goldmann tonometer by an ophthalmologist. In this study, statistically significant differences were found when comparing the ICare rebound tonometer with applanation tonometry (AT) (p < 0.05). The mean difference between the two tonometers was 1.34 +/- 2.03 mmHg (mean +/- S.D.) and the 95% limits of agreement were +/-3.98 mmHg. A frequency distribution of the differences demonstrated that in more than 80% of cases the IOP readings differed by <3 mmHg between the ICare and the AT. In the present population the ICare overestimates the IOP value by 1.34 mmHg on average when compared with Goldmann tonometer. Nevertheless, the ICare tonometer may be helpful as a screening tool when Goldmann applanation tonometry is not applicable or not recommended, as it is able to estimate IOP within a range of +/-3.00 mmHg in more than 80% of the populatio
Statistical properties of Pu, and Pu(n,) cross section calculation
The level density and gamma-ray strength function (gammaSF) of 243Pu have
been measured in the quasi-continuum using the Oslo method. Excited states in
243Pu were populated using the 242Pu(d,p) reaction. The level density closely
follows the constant-temperature level density formula for excitation energies
above the pairing gap. The gammaSF displays a double-humped resonance at low
energy as also seen in previous investigations of actinide isotopes. The
structure is interpreted as the scissors resonance and has a centroid of
omega_{SR}=2.42(5)MeV and a total strength of B_{SR}=10.1(15)mu_N^2, which is
in excellent agreement with sum-rule estimates. The measured level density and
gammaSF were used to calculate the 242Pu(n,gamma) cross section in a neutron
energy range for which there were previously no measured data.Comment: 9 pages, 8 figure
Low Energy Light Yield of Fast Plastic Scintillators
Compact neutron imagers using double-scatter kinematic reconstruction are
being designed for localization and characterization of special nuclear
material. These neutron imaging systems rely on scintillators with a rapid
prompt temporal response as the detection medium. As n-p elastic scattering is
the primary mechanism for light generation by fast neutron interactions in
organic scintillators, proton light yield data are needed for accurate
assessment of scintillator performance. The proton light yield of a series of
commercial fast plastic organic scintillators---EJ-200, EJ-204, and
EJ-208---was measured via a double time-of-flight technique at the 88-Inch
Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable deuteron
breakup neutron source, target scintillators housed in a dual photomultiplier
tube configuration, and an array of pulse-shape-discriminating observation
scintillators, the fast plastic scintillator light yield was measured over a
broad and continuous energy range down to proton recoil energies of
approximately 50 keV. This work provides key input to event reconstruction
algorithms required for utilization of these materials in emerging neutron
imaging modalities.Comment: 15 pages, 6 figure
Late local recurrence of dermatofibrosarcoma protuberans in the skin of female breast
Dermatofibrosarcoma protuberans (DFSP) of the breast is exceptionally obscure and late local recurrence of this entity on this site is even more uncommon. We describe such a case in a 48-year-old woman, who at the age of 35 had a DFSP excised from her right breast. Thirteen years later, she developed an ovoid mass in her right breast over the postsurgical scar area. Wide local excision of the tumor with generous tissue margin was performed and microscopic and immunohistochemical findings established the diagnosis of recurrent DFSP. No further treatment was administered and she remains well 18 months later, without tumor recurrence. We report an exceptionally rare case of local recurrence of DFSP in the female breast and discuss in detail the diagnostic and therapeutic implications of this pathology
- âŠ