6,866 research outputs found
Platelet kinetics in the pulmonary microcirculation in vivo assessed by intravital microscopy
Growing evidence supports the substantial pathophysiological impact of platelets on the development of acute lung injury. Methods for studying these cellular mechanisms in vivo are not present yet. The aim of this study was to develop a model enabling the quantitative analysis of platelet kinetics and platelet-endothelium interaction within consecutive segments of the pulmonary microcirculation in vivo. New Zealand White rabbits were anesthetized and ventilated. Autologous platelets were separated from blood and labeled ex vivo with rhodamine 6G. After implantation of a thoracic window, microhemodynamics and kinetics of platelets were investigated by intravital microscopy. Velocities of red blood cells (RBCs) and platelets were measured in arterioles, capillaries and venules, and the number of platelets adhering to the microvascular endothelium was counted. Kinetics of unstimulated platelets was compared with kinetics of thrombin-activated platelets. Velocity of unstimulated platelets was comparable to RBC velocity in all vessel segments. Unstimulated platelets passed the pulmonary microcirculation without substantial platelet-endothelial interaction. In contrast, velocity of activated platelets was decreased in all vascular segments indicating platelet margination and temporal platelet-endothelium interaction. Thrombin-activated platelets adhered to arteriolar endothelium; in capillaries and venules adherence of platelets was increased 8-fold and 13-fold, respectively. In conclusion, using intravital microscopy platelet kinetics were directly analyzed in the pulmonary microcirculation in vivo for the first time. In contrast to leukocytes, no substantial platelet-endothelium interaction occurs in the pulmonary microcirculation without any further stimulus. In response to platelet activation, molecular mechanisms enable adhesion of platelets in arterioles and venules as well as retention of platelets within capillaries. Copyright (C) 2002 S. Karger AG, Basel
Calibration of the LIGO displacement actuators via laser frequency modulation
We present a frequency modulation technique for calibration of the
displacement actuators of the LIGO 4-km-long interferometric gravitational-wave
detectors. With the interferometer locked in a single-arm configuration, we
modulate the frequency of the laser light, creating an effective length
variation that we calibrate by measuring the amplitude of the frequency
modulation. By simultaneously driving the voice coil actuators that control the
length of the arm cavity, we calibrate the voice coil actuation coefficient
with an estimated 1-sigma uncertainty of less than one percent. This technique
enables a force-free, single-step actuator calibration using a displacement
fiducial that is fundamentally different from those employed in other
calibration methods.Comment: 10 pages, 5 figures, submitted to Classical and Quantum Gravit
Implanting Site for Ralgro Compared to Synovex-S for Growing and Finishing Steers
Previous experiments (CATTLE 81-2) compared Ralgro implanted at the conventional shallow site, about mid-ear between skin and cartilage of the ear, and at an alternate deep site near the base of the ear to Synovex-S for finishing steers. In two experiments, the average improvements in weight gain for Ralgro at the shallow site, the deep site and Synovex-S were 8.3, 11.1 and 12.0%, respectively, over non-implanted controls. Feed efficiency was improved 7.1, 4.8 and 5.6%, respectively, over controls for these implant treatments. Additional data were considered desirable to include a growing phase as well as a finishing phase using the same implant treatments as in the previous experiments
Modular Multilevel Converter with Sensorless Diode-Clamped Balancing through Level-Adjusted Phase-Shifted Modulation
Cascaded H-bridge and modular multilevel converters (MMC) are on the rise
with emerging applications in renewable energy generation, energy storage, and
electric motor drives. However, their well-known advantages come at the price
of complicated balancing, high-bandwidth isolated monitoring, and numerous
sensors that can prevent MMCs from expanding into highly cost driven markets.
Therefore, an obvious trend in research is developing control and topologies
that depend less on measurements and benefit from simpler control.
Diode-clamped topologies are considered among the more applicable solutions.
The main problem with a diode-clamped topology is that it can only balance the
module voltages of a string in one direction; therefore, it cannot provide a
completely balanced operation. This paper proposes an effective balancing
technique for the diode-clamped topology. The proposed solution exploits the dc
component of the arm current by introducing a symmetrically level-adjusted
phase-shifted modulation scheme, and ensures the balancing current flow is
always in the correct direction. The main advantages of this method are
sensorless operation, no added computation and control effort, and low overall
cost. Analysis and detailed simulations provide insight into the operation of
the system as well as the new balancing technique and the experimental results
confirm the provided discussions
On the Brightness and Waiting-time Distributions of a Type III Radio Storm observed by STEREO/WAVES
Type III solar radio storms, observed at frequencies below approximately 16
MHz by space borne radio experiments, correspond to the quasi-continuous,
bursty emission of electron beams onto open field lines above active regions.
The mechanisms by which a storm can persist in some cases for more than a solar
rotation whilst exhibiting considerable radio activity are poorly understood.
To address this issue, the statistical properties of a type III storm observed
by the STEREO/WAVES radio experiment are presented, examining both the
brightness distribution and (for the first time) the waiting-time distribution.
Single power law behavior is observed in the number distribution as a function
of brightness; the power law index is approximately 2.1 and is largely
independent of frequency. The waiting-time distribution is found to be
consistent with a piecewise-constant Poisson process. This indicates that
during the storm individual type III bursts occur independently and suggests
that the storm dynamics are consistent with avalanche type behavior in the
underlying active region.Comment: 14 pages, 4 figures, 1 table. Accepted for publication in
Astrophysical Journal Letter
Discretized rotation has infinitely many periodic orbits
For a fixed k in (-2,2), the discretized rotation on Z^2 is defined by
(x,y)->(y,-[x+ky]). We prove that this dynamics has infinitely many periodic
orbits.Comment: Revised after referee reports, and added a quantitative statemen
Improving LIGO calibration accuracy by tracking and compensating for slow temporal variations
Calibration of the second-generation LIGO interferometric gravitational-wave
detectors employs a method that uses injected periodic modulations to track and
compensate for slow temporal variations in the differential length response of
the instruments. These detectors utilize feedback control loops to maintain
resonance conditions by suppressing differential arm length variations. We
describe how the sensing and actuation functions of these servo loops are
parameterized and how the slow variations in these parameters are quantified
using the injected modulations. We report the results of applying this method
to the LIGO detectors and show that it significantly reduces systematic errors
in their calibrated outputs.Comment: 13 pages, 8 figures. This is an author-created, un-copyedited version
of an article published in Classical and Quantum Gravity. IOP Publishing Ltd
is not responsible for any errors or omissions in this version of the
manuscript or any version derived from i
Evaluation of the Sustainability of an Intervention to Increase HIV Testing
BACKGROUND
Sustainability—the routinization and institutionalization of processes that improve the quality of healthcare—is difficult to achieve and not often studied.
OBJECTIVE
To evaluate the sustainability of increased rates of HIV testing after implementation of a multi-component intervention in two Veterans Health Administration healthcare systems.
DESIGN
Quasi-experimental implementation study in which the effect of transferring responsibility to conduct the provider education component of the intervention from research to operational staff was assessed.
PATIENTS
Persons receiving healthcare between 2005 and 2006 (intervention year) and 2006 and 2007 (sustainability year).
MEASUREMENTS
Monthly HIV testing rate, stratified by frequency of clinic visits
RESULTS
The monthly adjusted testing rate increased from 2% at baseline to 6% at the end intervention year and then declined reaching 4% at the end of the sustainability year. However, the stratified, visit-specific testing rate for persons newly exposed to the intervention (i.e., having their first through third visits during the study period) increased throughout the intervention and sustainability years. Increases in the proportion of visits by patients who remained untested despite multiple, prior exposures to the intervention accounted for the aggregate attenuation of testing during the sustainability year. Overall, the percentage of patients who received an HIV test in the sustainability year was 11.6%, in the intervention year 11.1%, and in the pre-intervention year 5.0%
CONCLUSIONS
Provider education combined with informatics and organizational support had a sustainable effect on HIV testing rates. The effect was most pronounced during patients' early contacts with the healthcare system.Health Services Research & Development Service (SDP 06–001
Precise calibration of LIGO test mass actuators using photon radiation pressure
Precise calibration of kilometer-scale interferometric gravitational wave
detectors is crucial for source localization and waveform reconstruction. A
technique that uses the radiation pressure of a power-modulated auxiliary laser
to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a
so-called photon calibrator, has been demonstrated previously and has recently
been implemented on the LIGO detectors. In this article, we discuss the
inherent precision and accuracy of the LIGO photon calibrators and several
improvements that have been developed to reduce the estimated voice coil
actuator calibration uncertainties to less than 2 percent (1-sigma). These
improvements include accounting for rotation-induced apparent length variations
caused by interferometer and photon calibrator beam centering offsets, absolute
laser power measurement using temperature-controlled InGaAs photodetectors
mounted on integrating spheres and calibrated by NIST, minimizing errors
induced by localized elastic deformation of the mirror surface by using a
two-beam configuration with the photon calibrator beams symmetrically displaced
about the center of the optic, and simultaneously actuating the test mass with
voice coil actuators and the photon calibrator to minimize fluctuations caused
by the changing interferometer response. The photon calibrator is able to
operate in the most sensitive interferometer configuration, and is expected to
become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit
Precise calibration of LIGO test mass actuators using photon radiation pressure
Precise calibration of kilometer-scale interferometric gravitational wave
detectors is crucial for source localization and waveform reconstruction. A
technique that uses the radiation pressure of a power-modulated auxiliary laser
to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a
so-called photon calibrator, has been demonstrated previously and has recently
been implemented on the LIGO detectors. In this article, we discuss the
inherent precision and accuracy of the LIGO photon calibrators and several
improvements that have been developed to reduce the estimated voice coil
actuator calibration uncertainties to less than 2 percent (1-sigma). These
improvements include accounting for rotation-induced apparent length variations
caused by interferometer and photon calibrator beam centering offsets, absolute
laser power measurement using temperature-controlled InGaAs photodetectors
mounted on integrating spheres and calibrated by NIST, minimizing errors
induced by localized elastic deformation of the mirror surface by using a
two-beam configuration with the photon calibrator beams symmetrically displaced
about the center of the optic, and simultaneously actuating the test mass with
voice coil actuators and the photon calibrator to minimize fluctuations caused
by the changing interferometer response. The photon calibrator is able to
operate in the most sensitive interferometer configuration, and is expected to
become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit
- …