52 research outputs found
Lipid-Iron Nanoparticle with a Cell Stress Release Mechanism Combined with a Local Alternating Magnetic Field Enables Site-Activated Drug Release
Simple Summary A novel active release system magnetic sphingomyelin-containing liposome encapsulated with indocyanine green, fluorescent marker, or the anticancer drug cisplatin was evaluated. The liposomal sphingomyelin is a target for the sphingomyelinase enzyme, which is released by stressed cells. Thus, sphingomyelin containing liposomes behave as a sensitizer for biological stress situations. In addition, the liposomes were engineered by adding paramagnetic beads to act as a receiver of outside given magnetic energy. The enzymatic activity towards liposomes and destruction caused by the applied magnetic field caused the release of the content from the liposomes. By using these novel liposomes, we could improve the drug release feature of liposomes. The improved targeting and drug-release were shown in vitro and the orthotopic tongue cancer model in mice optical imaging. The increased delivery of cisplatin prolonged the survival of the targeted delivery group versus free cisplatin. Most available cancer chemotherapies are based on systemically administered small organic molecules, and only a tiny fraction of the drug reaches the disease site. The approach causes significant side effects and limits the outcome of the therapy. Targeted drug delivery provides an alternative to improve the situation. However, due to the poor release characteristics of the delivery systems, limitations remain. This report presents a new approach to address the challenges using two fundamentally different mechanisms to trigger the release from the liposomal carrier. We use an endogenous disease marker, an enzyme, combined with an externally applied magnetic field, to open the delivery system at the correct time only in the disease site. This site-activated release system is a novel two-switch nanomachine that can be regulated by a cell stress-induced enzyme at the cellular level and be remotely controlled using an applied magnetic field. We tested the concept using sphingomyelin-containing liposomes encapsulated with indocyanine green, fluorescent marker, or the anticancer drug cisplatin. We engineered the liposomes by adding paramagnetic beads to act as a receiver of outside magnetic energy. The developed multifunctional liposomes were characterized in vitro in leakage studies and cell internalization studies. The release system was further studied in vivo in imaging and therapy trials using a squamous cell carcinoma tumor in the mouse as a disease model. In vitro studies showed an increased release of loaded material when stress-related enzyme and magnetic field was applied to the carrier liposomes. The theranostic liposomes were found in tumors, and the improved therapeutic effect was shown in the survival studies.Peer reviewe
FRAX (R): Prediction of Major Osteoporotic Fractures in Women from the General Population: The OPUS Study
Purposes: The aim of this study was to analyse how well FRAXH predicts the risk of major osteoporotic and vertebral
fractures over 6 years in postmenopausal women from general population.
Patients and methods: The OPUS study was conducted in European women aged above 55 years, recruited in 5 centers
from random population samples and followed over 6 years. The population for this study consisted of 1748 women (mean
age 74.2 years) with information on incident fractures. 742 (43.1%) had a prevalent fracture; 769 (44%) and 155 (8.9%) of
them received an antiosteoporotic treatment before and during the study respectively. We compared FRAXH performance
with and without bone mineral density (BMD) using receiver operator characteristic (ROC) c-statistical analysis with ORs and
areas under receiver operating characteristics curves (AUCs) and net reclassification improvement (NRI).
Results: 85 (4.9%) patients had incident major fractures over 6 years. FRAXH with and without BMD predicted these
fractures with an AUC of 0.66 and 0.62 respectively. The AUC were 0.60, 0.66, 0.69 for history of low trauma fracture alone,
age and femoral neck (FN) BMD and combination of the 3 clinical risk factors, respectively. FRAXH with and without BMD
predicted incident radiographic vertebral fracture (n = 65) with an AUC of 0.67 and 0.65 respectively. NRI analysis showed a
significant improvement in risk assignment when BMD is added to FRAXH.
Conclusions: This study shows that FRAXH with BMD and to a lesser extent also without FN BMD predict major osteoporotic
and vertebral fractures in the general population
Genome-Wide Association Study Using Extreme Truncate Selection Identifies Novel Genes Affecting Bone Mineral Density and Fracture Risk
Osteoporotic fracture is a major cause of morbidity and mortality worldwide. Low
bone mineral density (BMD) is a major predisposing factor to fracture and is
known to be highly heritable. Site-, gender-, and age-specific genetic effects
on BMD are thought to be significant, but have largely not been considered in
the design of genome-wide association studies (GWAS) of BMD to date. We report
here a GWAS using a novel study design focusing on women of a specific age
(postmenopausal women, age 55–85 years), with either extreme high or low
hip BMD (age- and gender-adjusted BMD z-scores of +1.5 to +4.0,
n = 1055, or −4.0 to −1.5,
n = 900), with replication in cohorts of women drawn from
the general population (n = 20,898). The study replicates
21 of 26 known BMD–associated genes. Additionally, we report suggestive
association of a further six new genetic associations in or around the genes
CLCN7, GALNT3, IBSP, LTBP3, RSPO3, and
SOX4, with replication in two independent datasets. A novel
mouse model with a loss-of-function mutation in GALNT3 is also
reported, which has high bone mass, supporting the involvement of this gene in
BMD determination. In addition to identifying further genes associated with BMD,
this study confirms the efficiency of extreme-truncate selection designs for
quantitative trait association studies
A meta-analysis of previous falls and subsequent fracture risk in cohort studies
NC Harvey acknowledges funding from the UK Medical Research Council (MC_PC_21003; MC_PC_21001). The WHI program is funded by the National Heart, Lung, and Blood Institute, National Institutes of Health, U.S. Department of Health and Human Services through 75N92021D00001, 75N92021D00002, 75N92021D00003, 75N92021D00004, and 75N92021D00005. Funding for the MrOS USA study comes from the National Institute on Aging (NIA), the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), the National Center for Advancing Translational Sciences (NCATS), and NIH Roadmap for Medical Research under the following grant numbers: U01 AG027810, U01 AG042124, U01 AG042139, U01 AG042140, U01 AG042143, U01 AG042145, U01 AG042168, U01 AR066160, and UL1 TR000128. Funding for the SOF study comes from the National Institute on Aging (NIA), and the National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS), supported by grants (AG05407, AR35582, AG05394, AR35584, and AR35583). Funding for the Health ABC study was from the Intramural research program at the National Institute on Aging under the following contract numbers: NO1-AG-6–2101, NO1-AG-6–2103, and NO1-AG-6–2106.Peer reviewedPostprin
Previous fracture and subsequent fracture risk : a meta-analysis to update FRAX
A large international meta-analysis using primary data from 64 cohorts has quantified the increased risk of fracture associated with a previous history of fracture for future use in FRAX. The aim of this study was to quantify the fracture risk associated with a prior fracture on an international basis and to explore the relationship of this risk with age, sex, time since baseline and bone mineral density (BMD). We studied 665,971 men and 1,438,535 women from 64 cohorts in 32 countries followed for a total of 19.5 million person-years. The effect of a prior history of fracture on the risk of any clinical fracture, any osteoporotic fracture, major osteoporotic fracture, and hip fracture alone was examined using an extended Poisson model in each cohort. Covariates examined were age, sex, BMD, and duration of follow-up. The results of the different studies were merged by using the weighted β-coefficients. A previous fracture history, compared with individuals without a prior fracture, was associated with a significantly increased risk of any clinical fracture (hazard ratio, HR = 1.88; 95% CI = 1.72-2.07). The risk ratio was similar for the outcome of osteoporotic fracture (HR = 1.87; 95% CI = 1.69-2.07), major osteoporotic fracture (HR = 1.83; 95% CI = 1.63-2.06), or for hip fracture (HR = 1.82; 95% CI = 1.62-2.06). There was no significant difference in risk ratio between men and women. Subsequent fracture risk was marginally downward adjusted when account was taken of BMD. Low BMD explained a minority of the risk for any clinical fracture (14%), osteoporotic fracture (17%), and for hip fracture (33%). The risk ratio for all fracture outcomes related to prior fracture decreased significantly with adjustment for age and time since baseline examination. A previous history of fracture confers an increased risk of fracture of substantial importance beyond that explained by BMD. The effect is similar in men and women. Its quantitation on an international basis permits the more accurate use of this risk factor in case finding strategies
Skeletal assessment with finite element analysis: Relevance, pitfalls and interpretation
Purpose of review Finite element models simulate the mechanical response of bone under load, enabling noninvasive assessment of strength. Models generated from quantitative computed tomography (QCT) incorporate the geometry and spatial distribution of bone mineral density (BMD) to simulate physiological and traumatic loads as well as orthopaedic implant behaviour. The present review discusses the current strengths and weakness of finite element models for application to skeletal biomechanics. Recent findings In cadaver studies, finite element models provide better estimations of strength compared to BMD. Data from clinical studies are encouraging; however, the superiority of finite element models over BMD measures for fracture prediction has not been shown conclusively, and may be sex and site dependent. Therapeutic effects on bone strength are larger than for BMD; however, model validation has only been performed on untreated bone. High-resolution modalities and novel image processing methods may enhance the structural representation and predictive ability. Despite extensive use of finite element models to study orthopaedic implant stability, accurate simulation of the bone-implant interface and fracture progression remains a significant challenge. Summary Skeletal finite element models provide noninvasive assessments of strength and implant stability. Improved structural representation and implant surface interaction may enable more accurate models of fragility in the future
The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone
Quantitative computed tomography-based finite element modeling technique is a promising clinical tool for the prediction of bone strength. However, quantitative computed tomography-based finite element models were created from image datasets with different image voxel sizes. The aim of this study was to investigate whether there is an influence of image voxel size on the finite element models. In all 12 thoracolumbar vertebrae were scanned prior to autopsy (in situ) using two different quantitative computed tomography scan protocols, which resulted in image datasets with two different voxel sizes (0.29 × 0.29 × 1.3 mm(3) vs 0.18 × 0.18 × 0.6 mm(3)). Eight of them were scanned after autopsy (in vitro) and the datasets were reconstructed with two voxel sizes (0.32 × 0.32 × 0.6 mm(3) vs. 0.18 × 0.18 × 0.3 mm(3)). Finite element models with cuboid volume of interest extracted from the vertebral cancellous part were created and inhomogeneous bilinear bone properties were defined. Axial compression was simulated. No effect of voxel size was detected on the apparent bone mineral density for both the in situ and in vitro cases. However, the apparent modulus and yield strength showed significant differences in the two voxel size group pairs (in situ and in vitro). In conclusion, the image voxel size may have to be considered when the finite element voxel modeling technique is used in clinical applications
High resolution quantitative computed tomography-based assessment of trabecular microstructure and strength estimates by finite-element analysis of the spine, but not DXA, reflects vertebral fracture status in men with glucocorticoid-induced osteoporosis
High-resolution quantitative computed tomography (HRQCT)-based analysis of spinal bone density and microstructure, finite element analysis (FEA), and DXA were used to investigate the vertebral bone status of men with glucocorticoid-induced osteoporosis (GIO). DXA of L1–L3 and total hip, QCT of L1–L3, and HRQCT of T12 were available for 73 men (54.6±14.0years) with GIO. Prevalent vertebral fracture status was evaluated on radiographs using a semi-quantitative (SQ) score (normal=0 to severe fracture=3), and the spinal deformity index (SDI) score (sum of SQ scores of T4 to L4 vertebrae). Thirty-one (42.4%) subjects had prevalent vertebral fractures. Cortical BMD (Ct.BMD) and thickness (Ct.Th), trabecular BMD (Tb.BMD), apparent trabecular bone volume fraction (app.BV/TV), and apparent trabecular separation (app.Tb.Sp) were analyzed by HRQCT. Stiffness and strength of T12 were computed by HRQCT-based nonlinear FEA for axial compression, anterior bending and axial torsion. In logistic regressions adjusted for age, glucocorticoid dose and osteoporosis treatment, Tb.BMD was most closely associated with vertebral fracture status (standardized odds ratio [sOR]: Tb.BMD T12: 4.05 [95% CI: 1.8–9.0], Tb.BMD L1–L3: 3.95 [1.8–8.9]). Strength divided by cross-sectional area for axial compression showed the most significant association with spine fracture status among FEA variables (2.56 [1.29–5.07]). SDI was best predicted by a microstructural model using Ct.Th and app.Tb.Sp (r2=0.57, p<0.001). Spinal or hip DXA measurements did not show significant associations with fracture status or severity.
In this cross-sectional study of males with GIO, QCT, HRQCT-based measurements and FEA variables were superior to DXA in discriminating between patients of differing prevalent vertebral fracture status. A microstructural model combining aspects of cortical and trabecular bone reflected fracture severity most accurately
- …