107 research outputs found

    A randomized multicenter trial comparing the XIENCE everolimus eluting stent with the CYPHER sirolimus eluting stent in the treatment of female patients with de novo coronary artery lesions: The SPIRIT WOMEN study

    Get PDF
    Background: The comparative performance of different drug-eluting stents (DES) among female patients has not been assessed in a randomized manner. Objectives: The SPIRIT Women Clinical Evaluation trial compared the durable polymer everolimus-eluting XIENCE stent (DP-EES) with the durable polymer sirolimus-eluting Cypher stent (DP-SES) in women undergoing percutaneous coronary intervention (PCI). Methods: A total of 455 female patients with stable CAD were randomly assigned to receive DP-EES (n = 304) or DP-SES (n = 151). The powered angiographic outcome of the trial was in-stent late lumen loss (LLL) at 9 months after the index procedure. Secondary angiographic end points included in-segment LLL, in-stent and in-segment binary restenosis and percent diameter stenosis. The primary clinical outcome was a composite of all-cause death, myocardial infarction (MI) or target vessel revascularization (TVR). Results: At 9-month follow-up, in-stent LLL was 0.19\uc2\ub10.38 mm and 0.11\uc2\ub10.37 mm in patients assigned to DP-EES and DP-SES, respectively. The one-sided upper 95% CI of the difference in in-stent LLL between the groups of 0.08 mm was 0.15 and therefore within the pre-specified non-inferiority margin of 0.17 mm (p for non-inferiority = 0.013). However, the test for superiority showed a borderline significant difference in terms of LLL between DP-EES and DP-SES (p for superiority = 0.044). There were no significant differences in binary restenosis (2.0% vs. 0.72%, p = 0.44) and percent diameter stenosis (14.97\uc2\ub112.17 vs. 13.36 \uc2\ub110.82, p = 0.19). The rate of definite stent thrombosis at 12 months was lower in patients treated with DP-EES (0% vs. 2.0%, p = 0.036). Conclusions: Among women undergoing PCI, DP-EES was associated with a small but probably clinically relevant increase in in-stent LLL at 9 months as compared to DP-SES and with a lower risk of definite stent thrombosis at 12 months. Trial registration: ClinicalTrials.gov NCT01182428

    Revisiting Sex Equality With Transcatheter Aortic Valve Replacement Outcomes A Collaborative, Patient-Level Meta-Analysis of 11,310 Patients

    Get PDF
    AbstractBackgroundThere has been conflicting clinical evidence as to the influence of female sex on outcomes after transcatheter aortic valve replacement.ObjectivesThe aim of this study was to evaluate the impact of sex on early and late mortality and safety end points after transcatheter aortic valve replacement using a collaborative meta-analysis of patient-level data.MethodsFrom the MEDLINE, Embase, and the Cochrane Library databases, data were obtained from 5 studies, and a database containing individual patient-level time-to-event data was generated from the registry of each selected study. The primary outcome of interest was all-cause mortality. The safety end point was the combined 30-day safety end points of major vascular complications, bleeding events, and stroke, as defined by the Valve Academic Research Consortium when available.ResultsFive studies and their ongoing registry data, comprising 11,310 patients, were included. Women constituted 48.6% of the cohort and had fewer comorbidities than men. Women had a higher rate of major vascular complications (6.3% vs. 3.4%; p < 0.001), major bleeding events (10.5% vs. 8.5%; p = 0.003), and stroke (4.4% vs. 3.6%; p = 0.029) but a lower rate of significant aortic incompetence (grade ≥2; 19.4% vs. 24.5%; p < 0.001). There were no differences in procedural and 30-day mortality between women and men (2.6 % vs. 2.2% [p = 0.24] and 6.5% vs. 6.5% [p = 0.93], respectively), but female sex was independently associated with improved survival at median follow-up of 387 days (interquartile range: 192 to 730 days) from the index procedure (adjusted hazard ratio: 0.79; 95% confidence interval: 0.73 to 0.86; p = 0.001).ConclusionsAlthough women experience more bleeding events, as well as vascular and stroke complications, female sex is an independent predictor of late survival after transcatheter aortic valve replacement. This should be taken into account during patient selection for this procedure

    Prevalence, predictors, and outcomes of patient prosthesis mismatch in women undergoing TAVI for severe aortic stenosis: Insights from the WIN-TAVI registry

    Get PDF
    Objective: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). Background: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. Methods: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry i

    Impact of Percutaneous Revascularization on Exercise Hemodynamics in Patients With Stable Coronary Disease

    Get PDF
    Background: Recently, the therapeutic benefits of percutaneous coronary intervention (PCI) have been challenged in patients with stable coronary artery disease (SCD). Objectives: The authors examined the impact of PCI on exercise responses in the coronary circulation, the microcirculation, and systemic hemodynamics in patients with SCD. Methods: A total of 21 patients (mean age 60.3 ± 8.4 years) with SCD and single-vessel coronary stenosis underwent cardiac catheterization. Pre-PCI, patients exercised on a supine ergometer until rate-limiting angina or exhaustion. Simultaneous trans-stenotic coronary pressure-flow measurements were made throughout exercise. Post-PCI, this process was repeated. Physiological parameters, rate-limiting symptoms, and exercise performance were compared between pre-PCI and post-PCI exercise cycles. Results: PCI reduced ischemia as documented by fractional flow reserve value (pre-PCI 0.59 ± 0.18 to post-PCI 0.91 ± 0.07), instantaneous wave-free ratio value (pre-PCI 0.61 ± 0.27 to post-PCI 0.96 ± 0.05) and coronary flow reserve value (pre-PCI 1.7 ± 0.7 to post-PCI 3.1 ± 1.0; p < 0.001 for all). PCI increased peak-exercise average peak coronary flow velocity (p < 0.0001), coronary perfusion pressure (distal coronary pressure; p < 0.0001), systolic blood pressure (p = 0.01), accelerating wave energy (p < 0.001), and myocardial workload (rate-pressure product; p < 0.01). These changes observed immediately following PCI resulted from the abolition of stenosis resistance (p < 0.0001). PCI was also associated with an immediate improvement in exercise time (+67 s; 95% confidence interval: 31 to 102 s; p < 0.0001) and a reduction in rate-limiting angina symptoms (81% reduction in rate-limiting angina symptoms post-PCI; p < 0.001). Conclusions: In patients with SCD and severe single-vessel stenosis, objective physiological responses to exercise immediately normalize following PCI. This is seen in the coronary circulation, the microcirculation, and systemic hemodynamics

    Pre-Angioplasty Instantaneous Wave-Free Ratio Pullback Predicts Hemodynamic Outcome In Humans With Coronary Artery Disease: Primary Results of the International Multicenter iFR GRADIENT Registry.

    Get PDF
    The authors sought to evaluate the accuracy of instantaneous wave-Free Ratio (iFR) pullback measurements to predict post-percutaneous coronary intervention (PCI) physiological outcomes, and to quantify how often iFR pullback alters PCI strategy in real-world clinical settings.This article is freely available via Open Access. Please click on the Additional Link above to access the full-text via the publisher's site
    • …
    corecore