19 research outputs found

    Specsim: The MIRI Medium Resolution Spectrometer Simulator

    Get PDF
    MIRI, the Mid-InfraRed Instrument, is one of four instruments being built for the James Webb Space Telescope, and is developed jointly between an EuropeanConsortium and the US. In this paper we present a software data simulator for one of MIRI's four instruments: the Integral Field Unit (IFU) Medium Resolution Spectrometer (MIRI-MRS), the first mid-infrared IFU spectrograph, and one of the first IFUs to be used in a space mission. To give the MIRI community a preview of the properties of the MIRI-MRS data products before the telescope is operational, the Specsim tool has been developed to model, in software, the operation of the spectrometer. Specsim generates synthetic data frames approximating those which will be taken by the instrument in orbit. The program models astronomical sources and generates detector frames using the predicted and measured optical properties of the telescope and MIRI. These frames can then be used to illustrate and inform a range of operational activities, including data calibration strategies and the development and testing of the data reduction software for the MIRI-MRS. Specsim will serve as a means of communication between the many consortium members by providing a way to easily illustrate the performance of the spectrometer under different circumstances, tolerances of components and design scenarios.Comment: 8 pages, 5 figures; A high resolution version is available at http://www.roe.ac.uk/~npfl/Publications/lgw+06.ps.gz (Changed URL of high-res version

    Integral field spectroscopy of the Luminous Infrared Galaxy Arp299 (IC694+NGC3690)

    Get PDF
    The luminous infrared galaxy Arp299 (IC694+NGC3690) is studied using optical integral field spectroscopy obtained with the INTEGRAL system, together with archival Hubble Space Telescope WFPC2 and NICMOS images. The stellar and ionized gas morphology shows lambda-dependent variations due to the combined effects of the dust internal extinction, and the nature and spatial distribution of the different ionizing sources. The two-dimensional ionization maps have revealed an off-nuclear conical structure of about 4 kpc in length, characterized by high excitation conditions and a radial gradient in the gas electron density. The apex of this structure coincides with B1 region of NGC3690 which, in turn, presents Seyfert-like ionization, high extinction and a high velocity dispersion. These results strongly support the hypothesis that B1 is the true nucleus of NGC3690, where an AGN is located. In the circumnuclear regions HII-like ionization dominates, while LINER-like ionization is found elsewhere. The Halpha emitting sources with ages from 3.3 to 7.2x10^6 years, have masses of between 6 and 680x10^6 Msun and contribute (extinction corrected) about 45% to the bolometric luminosity. The ionized (Halpha) and neutral (NaD) gas velocity fields show similar structure on scales of several hundred to about 1 kpc, indicating that these gas components are kinematically coupled. The kinematic structure is complex and on scales of about 0.2 kpc does not appear to be dominated by the presence of ordered, rotational motions. The large velocity dispersion measured in NGC3690 indicates that this galaxy is the most massive of the system. The low velocity amplitude and dispersion of the interface suggest that the ionized gas is slowly rotating or in a close to quiescent phase.Comment: 35 pages, 19 figures, Accepted for publication in the Astrophysical Journal, Paper with full resolution figures available at http://www.damir.iem.csic.es/extragalactic/publications/publications.htm

    Discovery of Blue Hook Stars in the Massive Globular Cluster M54

    Full text link
    We present BV photometry centered on the globular cluster M54 (NGC 6715). The color-magnitude diagram clearly shows a blue horizontal branch extending anomalously beyond the zero age horizontal branch theoretical models. These kinds of horizontal branch stars (also called ``blue hook'' stars), which go beyond the lower limit of the envelope mass of canonical horizontal branch hot stars, have so far been known to exist in only a few globular clusters: NGC 2808, Omega Centauri (NGC 5139), NGC 6273, and NGC 6388. Those clusters, like M54, are among the most luminous in our Galaxy, indicating a possible correlation between the existence of these types of horizontal branch stars and the total mass of the cluster. A gap in the observed horizontal branch of M54 around T(eff)= 27000 K could be interpreted within the late helium flash theoretical scenario, a possible explanation for the origin of those stars.Comment: 10 pages, 2 figures, accepted for publication in the Astrophysical Journa

    Atresia anal en el perro y el gato

    Get PDF
    Ponencia en el XXXI CONGRESO NACIONAL DE LA ASOCIACIÓN MEXICANA DE MÉDICOS VETERINARIOS ESPECIALISTAS EN PEQUEÑAS ESPECIES, A.C.La atresia anal es una patología poco frecuente con una prevalencia del 0.13% y del 1.6% para el caso de los perros y de los gatos menores de un año de edad respectivamente, atendidos en nuestro centro hospitalario. En el presente documento se expone la experiencia en el diagnóstico y manejo de tres pacientes con atresia anal, realizamos una revisión de las teorías de los mecanismos fisiopatológicos involucrados en el desarrollo embrionario, y con base en esos criterios, sugerimos la mejor clasificación del tipo de atresia anal partiendo del análisis de las propuestas existentes y su relación con los conceptos actuales de la anatomía embriológica

    Case-Control Analysis of the Impact of Anemia on Quality of Life in Patients with Cancer: A Qca Study Analysis

    Get PDF
    The impact of anemia on the quality of life (QoL) in cancer patients has been studied previously; however, the cut-off point used to define anemia differed among studies, thus providing inconsistent results. Therefore, we analysed the clinical impact of anemia on QoL using the same cut-off point for hemoglobin level to define anemia as that used in ESMO clinical practice guidelines. This post-hoc analysis aimed to determine the impact of anemia on QoL in cancer patients through the European Organization for Research and Treatment of Cancer Quality of life questionnaire version 3.0 (EORTC QLQ-C30) and Euro QoL 5-dimension 3-level (EQ-5D-3L) questionnaire. We found that cancer patients with anemia had significantly worse QoL in clinical terms. In addition, anemic patients had more pronounced symptoms than those in non-anemic patients. Anemia is a common condition in cancer patients and is associated with a wide variety of symptoms that impair quality of life (QoL). However, exactly how anemia affects QoL in cancer patients is unclear because of the inconsistencies in its definition in previous reports. We aimed to examine the clinical impact of anemia on the QoL of cancer patients using specific questionnaires. We performed a post-hoc analysis of a multicenter, prospective, case-control study. We included patients with cancer with (cases) or without (controls) anemia. Participants completed the European Organization for Research and Treatment of Cancer Quality of Life questionnaire version 3.0 (EORTC QLQ-C30) and Euro QoL 5-dimension 3-level (EQ-5D-3L) questionnaire. Statistically significant and clinically relevant differences in the global health status were examined. From 2015 to 2018, 365 patients were included (90 cases and 275 controls). We found minimally important differences in global health status according to the EORTC QLQ-C30 questionnaire (case vs. controls: 45.6 vs. 58%, respectively; mean difference: -12.4, p < 0.001). Regarding symptoms, cancer patients with anemia had more pronounced symptoms in six out of nine scales in comparison with those without anemia. In conclusion, cancer patients with anemia had a worse QoL both clinically and statistically

    Life beyond 30: Probing the-20 < M (UV) <-17 Luminosity Function at 8 < z < 13 with the NIRCam Parallel Field of the MIRI Deep Survey

    Get PDF
    We present the ultraviolet luminosity function and an estimate of the cosmic star formation rate density at 8 8 galaxy candidates based on their dropout nature in the F115W and/or F150W filters, a high probability for their photometric redshifts, estimated with three different codes, being at z > 8, good fits based on χ 2 calculations, and predominant solutions compared to z < 8 alternatives. We find mild evolution in the luminosity function from z ∼ 13 to z ∼ 8, i.e., only a small increase in the average number density of ∼0.2 dex, while the faint-end slope and absolute magnitude of the knee remain approximately constant, with values α = − 2.2 ± 0.1, and M * = − 20.8 ± 0.2 mag. Comparing our results with the predictions of state-of-the-art galaxy evolution models, we find two main results: (1) a slower increase with time in the cosmic star formation rate density compared to a steeper rise predicted by models; (2) nearly a factor of 10 higher star formation activity concentrated in scales around 2 kpc in galaxies with stellar masses ∼108 M ⊙ during the first 350 Myr of the universe, z ∼ 12, with models matching better the luminosity density observational estimations ∼150 Myr later, by z ∼ 9

    The Science Performance of JWST as Characterized in Commissioning

    Full text link
    This paper characterizes the actual science performance of the James Webb Space Telescope (JWST), as determined from the six month commissioning period. We summarize the performance of the spacecraft, telescope, science instruments, and ground system, with an emphasis on differences from pre-launch expectations. Commissioning has made clear that JWST is fully capable of achieving the discoveries for which it was built. Moreover, almost across the board, the science performance of JWST is better than expected; in most cases, JWST will go deeper faster than expected. The telescope and instrument suite have demonstrated the sensitivity, stability, image quality, and spectral range that are necessary to transform our understanding of the cosmos through observations spanning from near-earth asteroids to the most distant galaxies.Comment: 5th version as accepted to PASP; 31 pages, 18 figures; https://iopscience.iop.org/article/10.1088/1538-3873/acb29

    The Mid-Infrared Instrument for the James Webb Space Telescope, IX: Predicted Sensitivity

    No full text
    We present an estimate of the performance that will be achieved during on-orbit operations of the JWST mid-infrared instrument, MIRI. The efficiency of the main imager and spectrometer systems in detecting photons from an astronomical target are presented, based on measurements at subsystem and instrument-level testing, with the end-to-end transmission budget discussed in some detail. The brightest target fluxes that can be measured without saturating the detectors are provided. The sensitivity for long-duration observations of faint sources is presented in terms of the target flux required to achieve a signal-to-noise ratio of 10 after a 10,000 s observation. The algorithms used in the sensitivity model are presented, including the understanding gained during testing of the MIRI flight model and flight-like detectors.status: publishe

    Time series observations with the mid-infrared instrument (MIRI) on JWST

    No full text
    Time-variable phenomena such as transiting exoplanets will be a major science theme for the James Webb Space Telescope (JWST). For Guaranteed Time and Early Release Science Observations, over 500 hours of JWST time have been allocated to time series observations (TSOs) of transiting exoplanets. Several dedicated observing modes are available in the instrument suite, whose operations are specifically tailored to these challenging observations. MIRI, the only JWST instrument covering the wavelength range longwards of 5 mu m on JWST, will offer TSOs in two of its modes: the low resolution spectrometer, and the imager. In this paper we will describe these modes for MIRI, and discuss how they differ operationally from regular (non-TSO) observations. We will show performance estimates based on ground testing and modeling, discuss the most relevant detector effects for high precision (spectro-)photometry, and provide some guidelines for planning MIRI TSOs.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
    corecore