25 research outputs found

    Surgical management of tricuspid regurgitation: a new algorithm to minimise recurrent tricuspid regurgitation

    Get PDF
    Introduction Recurrent tricuspid regurgitation (TR) is frequently observed after cardiac surgery; however, the correct approach remains controversial. We developed an algorithm for action on the tricuspid valve (TV) and conducted a 1-year follow-up study. The aim was to assess the efficacy of the algorithm to minimise residual TR after TV surgery. The hypothesis was that the TR rate at 1 year would be reduced by selecting the surgical approach in accordance with a set of preoperative clinical and echocardiographic variables. Methods A prospective, observational, single-centre study was performed in 76 consecutive patients with TV involvement. A protocol was designed for their inclusion, and data on their clinical and echocardiographic characteristics were gathered at 3 months and 1-year postsurgery. The treatment of patients depended on the degree of TR. Surgery was performed in all patients with severe or moderate-to- severe TR and in those with mild or moderate TR alongside the presence of certain clinical or echocardiographic factors. They underwent annuloplasty or extended valve repair when the TV was distorted. If repair techniques were not feasible, a prosthesis was implanted. Residual TR rates were compared with published reports, and predictors of early/late mortality and residual TR were evaluated. Results TR was functional in 69.9% of patients. Rigid ring annuloplasty was performed in 35.7% of patients, De Vega annuloplasty in 27.1%, extended repair in 11.4% and prosthetic replacement in 25.7%. TR was moderate or worse in 8.19% of patients (severe in 3.27%) at 1 year postintervention. No clinical, surgical or epidemiological variables were significantly associated with residual TR persistence, although annulus diameter showed a close-to- significant association. Total mortality was 12.85% for all causes and 10% for cardiovascular causes. In multivariate analysis, left ventricular ejection fraction was related to both early and late mortality. Conclusions Severe residual TR was significantly less frequent than reported in other series, being observed in less than 4% of patients at 1-year postsurgery

    Behavior of echocardiographic parameters of right ventricular function after tricuspid surgery

    Get PDF
    Evaluation of right ventricular (RV) function after tricuspid valve surgery is complex. The objective was to identify the most appropriate RV function parameters for this purpose. This prospective study included 70 patients undergoing cardiac and tricuspid valve (TV) surgery. RV size and function parameters were determined at 3 months and 1-year post-surgery. Categorical variables were analyzed with the McNemar test and numerical variables with the Student’s t-test for related samples or, when non-normally distributed, the Wilcoxon test. Spearman’s rho was used to determine correlations between variables at 3 months and 1 year. RV diameters were reduced at 3 months postsurgery and were then unchanged at 1 year. Tricuspid annular plane systolic excursion (TAPSE) and S′ wave values were worse at 3 months and then improved at 1 year (t-score-2.35, p 0.023; t-score-2.68; p 0.010). There was no significant reduction in free wall longitudinal strain (LS) or shortening fraction (SF) at 3 months (t-score 1.421 and − 1.251; p 0.218 and 0.172), and they were only slightly below presurgical values at 1 year. No relationship was found between RV function parameters and mortality or major complications. During the first few months after TV surgery, LS may be a more appropriate parameter to evaluate global ventricular function in comparison to TAPSE. At 1 year, good correlations are observed between TAPSE, S′ wave, and LS values

    Predicting sudden cardiac death in adults with congenital heart disease

    Get PDF
    [Objectives] To develop, calibrate, test and validate a logistic regression model for accurate risk prediction of sudden cardiac death (SCD) and non-fatal sudden cardiac arrest (SCA) in adults with congenital heart disease (ACHD), based on baseline lesion-specific risk stratification and individual’s characteristics, to guide primary prevention strategies.[Methods] We combined data from a single-centre cohort of 3311 consecutive ACHD patients (50% male) at 25-year follow-up with 71 events (53 SCD and 18 non-fatal SCA) and a multicentre case–control group with 207 cases (110 SCD and 97 non-fatal SCA) and 2287 consecutive controls (50% males). Cumulative incidences of events up to 20 years for specific lesions were determined in the prospective cohort. Risk model and its 5-year risk predictions were derived by logistic regression modelling, using separate development (18 centres: 144 cases and 1501 controls) and validation (two centres: 63 cases and 786 controls) datasets.[Results] According to the combined SCD/SCA cumulative 20 years incidence, a lesion-specific stratification into four clusters—very-low (12%)—was built. Multivariable predictors were lesion-specific cluster, young age, male sex, unexplained syncope, ischaemic heart disease, non-life threatening ventricular arrhythmias, QRS duration and ventricular systolic dysfunction or hypertrophy. The model very accurately discriminated (C-index 0.91; 95% CI 0.88 to 0.94) and calibrated (p=0.3 for observed vs expected proportions) in the validation dataset. Compared with current guidelines approach, sensitivity increases 29% with less than 1% change in specificity.[Conclusions] Predicting the risk of SCD/SCA in ACHD can be significantly improved using a baseline lesion-specific stratification and simple clinical variables.Peer reviewe

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist’s perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of cen‑ tral tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfed in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores>70/100 from the frst procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies : a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images

    Persistent Pulmonary Hypertension in Corrected Valvular Heart Disease: Hemodynamic Insights and Long-Term Survival.

    Get PDF
    Background The determinants and consequences of pulmonary hypertension after successfully corrected valvular heart disease remain poorly understood. We aim to clarify the hemodynamic bases and risk factors for mortality in patients with this condition. Methods and Results We analyzed long-term follow-up data of 222 patients with pulmonary hypertension and valvular heart disease successfully corrected at least 1 year before enrollment who had undergone comprehensive hemodynamic and imaging characterization as per the SIOVAC (Sildenafil for Improving Outcomes After Valvular Correction) clinical trial. Median (interquartile range) mean pulmonary pressure was 37 mm Hg (32-44 mm Hg) and pulmonary artery wedge pressure was 23 mm Hg (18-26 mm Hg). Most patients were classified either as having combined precapillary and postcapillary or isolated postcapillary pulmonary hypertension. After a median follow-up of 4.5 years, 91 deaths accounted for 4.21 higher-than-expected mortality in the age-matched population. Risk factors for mortality were male sex, older age, diabetes mellitus, World Health Organization functional class III and higher pulmonary vascular resistance-either measured by catheterization or approximated from ultrasound data. Higher pulmonary vascular resistance was related to diabetes mellitus and smaller residual aortic and mitral valve areas. In turn, the latter correlated with prosthetic nominal size. Six-month changes in the composite clinical score and in the 6-minute walk test distance were related to survival. Conclusions Persistent valvular heart disease-pulmonary hypertension is an ominous disease that is almost universally associated with elevated pulmonary artery wedge pressure. Pulmonary vascular resistance is a major determinant of mortality in this condition and is related to diabetes mellitus and the residual effective area of the corrected valve. These findings have important implications for individualizing valve correction procedures. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT00862043.This study was funded by the Instituto de Salud Carlos III, Ministerio de Ciencia e Innovación, Spain, the European Union–European Regional Development Fund (EC07/90772 and PI19/00649), and the Consorcio de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV).S

    Pasados y presente. Estudios para el profesor Ricardo García Cárcel

    Get PDF
    Ricardo García Cárcel (Requena, 1948) estudió Historia en Valencia bajo el magisterio de Joan Reglà, con quien formó parte del primer profesorado de historia moderna en la Universidad Autónoma de Barcelona. En esta universidad, desde hace prácticamente cincuenta años, ha desarrollado una extraordinaria labor docente y de investigación marcada por un sagaz instinto histórico, que le ha convertido en pionero de casi todo lo que ha estudiado: las Germanías, la historia de la Cataluña moderna, la Inquisición, las culturas del Siglo de Oro, la Leyenda Negra, Felipe II, Felipe V, Austrias y Borbones, la guerra de la Independencia, la historia cultural, los mitos de la historia de España... Muy pocos tienen su capacidad para reflexionar, ordenar, analizar, conceptualizar y proponer una visión amplia y llena de matices sobre el pasado y las interpretaciones historiográficas. A su laboriosidad inimitable se añade una dedicación sin límites en el asesoramiento de alumnos e investigadores e impulsando revistas, dosieres, seminarios o publicaciones colectivas. Una mínima correspondencia a su generosidad lo constituye este volumen a manera de ineludible agradecimiento

    Infective endocarditis on interventricular communication as cause of massive haemoptysis: a case report.

    No full text
    Haemoptysis is a rare symptom associated with endocarditis. We describe the unusual clinical manifestation of endocarditis on regurgitant bicuspid aortic valve and (probably) secondarily on a perimembranous ventricular septal defect (VSD) as massive haemoptysis. A 24-year-old male with aortic coarctation, bicuspid aortic valve, and VSD since birth. Previously asymptomatic, he came after an episode of haemoptysis. A computed tomography (CT) scan showed a cavitated lesion in lung. Streptococo viridans was identified in serial blood cultures. Transthoracic echocardiography showed a bicuspid aortic valve with vegetations, suggesting infectious involvement, and severe aortic insufficiency. Transoesophageal echocardiography (TEE) study showed a bicuspid aortic valve with complete fusion of coronary valves. An elongated oscillating tumour, 9.5 mm in length, was observed in the centre of the ventricular side of the non-coronary valve. Another vegetation was seen on the VSD. During his hospital stay and under antibiotic treatment, he reported abdominal pain. Computed tomography examination showed splenic infarction. In the echocardiogram no vegetation masses were observed on the aortic valve or on the VSD closure aneurysm. The main debate about this patient's treatment concerned the indication of surgery, especially after the onset of fever with splenic septic embolism while under appropriate antibiotic treatment. He was stable, with no signs of heart failure and the echocardiogram repeated after the septic splenic embolism showed no residual vegetations on the aortic valve or VSD, and the TEE study ruled out a local complication. Finally, the multidisciplinary team decided against surgical management
    corecore