18 research outputs found

    Retrieval of phase relation and emission profile of quantum cascade laser frequency combs

    Full text link
    The major development recently undergone by quantum cascade lasers has effectively extended frequency comb emission to longer-wavelength spectral regions, i.e. the mid and far infrared. Unlike classical pulsed frequency combs, their mode-locking mechanism relies on four-wave mixing nonlinear processes, with a temporal intensity profile different from conventional short-pulses trains. Measuring the absolute phase pattern of the modes in these combs enables a thorough characterization of the onset of mode-locking in absence of short-pulses emission, as well as of the coherence properties. Here, by combining dual-comb multi-heterodyne detection with Fourier-transform analysis, we show how to simultaneously acquire and monitor over a wide range of timescales the phase pattern of a generic frequency comb. The technique is applied to characterize a mid-infrared and a terahertz quantum cascade laser frequency comb, conclusively proving the high degree of coherence and the remarkable long-term stability of these sources. Moreover, the technique allows also the reconstruction of electric field, intensity profile and instantaneous frequency of the emission.Comment: 20 pages. Submitted to Nature Photonic

    Doubly resonant photoacoustic spectroscopy: ultra-high sensitivity meets ultra-wide dynamic range

    Full text link
    Photoacoustic spectroscopy (PAS) based gas sensors with high sensitivity, wide dynamic range, low cost, and small footprint are desirable across a broad range of applications in energy, environment, safety, and public health. However, most works have focused on either acoustic resonator to enhance acoustic wave or optical resonator to enhance optical wave. Herein, we develop a gas sensor based on doubly resonant PAS in which the acoustic and optical waves are simultaneously enhanced using combined optical and acoustic resonators in a centimeter-long configuration. Not only the lower detection limit is enhanced by the double standing waves, but also the upper detection limit is expanded due to the short resonators. As an example, we developed a sensor by detecting acetylene (C2H2), achieving a noise equivalent absorption of 5.7*10-13 cm-1 and a dynamic range of eight orders. Compared to the state-of-the-art PAS gas sensors, the developed sensor increases the sensitivity by two orders of magnitude and extends the dynamic range by three orders of magnitude. Besides, a laser-cavity-molecule locking strategy is proposed to provide additional flexibility of fast gas detection

    Prevention of Recurrent Benign Paroxysmal Positional Vertigo: The Role of Combined Supplementation with Vitamin D and Antioxidants

    Get PDF
    Benign paroxysmal positional vertigo (BPPV) usually has a favorable course, although it is possible to observe BPPV with a high recurrence rate. Previous studies suggested that vitamin D deficiency might affect BPPV recurrences, and oxidative stress might play a complementary role in BPPV pathogenesis. This multicentric trial aimed to evaluate the effectiveness of oral nutritional supplementation with a compound of alpha-lipoic acid, Carnosine, and Zinc (LICA (R) (Difass International, Coriano (RN), Italy)), vitamins of group B and vitamin D in preventing BPPV recurrences. A total of 128 patients with high recurrence-BPPV were randomized in three arms: Arm 1 consisted of subjects with "insufficient" or "deficient" vitamin D blood levels, treated with daily oral supplementation of LICA (R), vitamins of group B and vitamin D3 (800 UI), Arm 2 included BPPV subjects with "sufficient" vitamin D who did not receive any nutritional support, and Arm 3 included subjects with a "sufficient" serum concentration of vitamin D who received supplementation with a compound of LICA (R) and Curcumin. After six months of follow-up, a significant reduction of BPPV relapses compared to the baseline was found only in Arm 1 (-2.32, 95% CI: 3.41-1.62, p-value < 0.0001). Study results suggested that oral nutritional supplementation with vitamin D3 plus antioxidants can prevent relapses in patients suffering from high recurrence-BPPV

    Multicentric Atrial Strain COmparison between Two Different Modalities: MASCOT HIT Study

    Get PDF
    Two methods are currently available for left atrial (LA) strain measurement by speckle tracking echocardiography, with two different reference timings for starting the analysis: QRS (QRS-LASr) and P wave (P-LASr). The aim of MASCOT HIT study was to define which of the two was more reproducible, more feasible, and less time consuming. In 26 expert centers, LA strain was analyzed by two different echocardiographers (young vs senior) in a blinded fashion. The study population included: healthy subjects, patients with arterial hypertension or aortic stenosis (LA pressure overload, group 2) and patients with mitral regurgitation or heart failure (LA volume–pressure overload, group 3). Difference between the inter-correlation coefficient (ICC) by the two echocardiographers using the two techniques, feasibility and analysis time of both methods were analyzed. A total of 938 subjects were included: 309 controls, 333 patients in group 2, and 296 patients in group 3. The ICC was comparable between QRS-LASr (0.93) and P-LASr (0.90). The young echocardiographers calculated QRS-LASr in 90% of cases, the expert ones in 95%. The feasibility of P-LASr was 85% by young echocardiographers and 88% by senior ones. QRS-LASr young median time was 110 s (interquartile range, IR, 78-149) vs senior 110 s (IR 78-155); for P-LASr, 120 s (IR 80-165) and 120 s (IR 90-161), respectively. LA strain was feasible in the majority of patients with similar reproducibility for both methods. QRS complex guaranteed a slightly higher feasibility and a lower time wasting compared to the use of P wave as the reference

    Il diritto della navigazione come strumento di tutela. Alcuni problemi in tema di protezione dell'ambiente marino, safety e security.

    No full text
    Questo elaborato ha l’obbiettivo di esporre come negli ultimi decenni attraverso il modello giuridico che regola la governance marittima, si sia data sempre più importanza alla prevenzione e alla tutela dell’ambiente marino e costiero, alla salute e alla sicurezza del personale marittimo a bordo delle navi e a quello operante nei porti. Il tema del rapporto tra l’economia del mare, quale modalità per trasportare da una nazione ad un’altra, da un continente ad un altro merci e persone e il conseguente impatto di questa attività sull’ambiente e sulla sicurezza di chi vi opera, ha spinto sempre più le comunità nazionali ed internazionali a disciplinare questa modalità di trasporto con l’intento specifico di salvaguardare l’ambiente e la salute dei soggetti che vi operano. Il percorso si articola con l’analisi delle normative introdotte a complemento della materia del diritto della navigazione, normative che rappresentano un sistema complesso, determinato anche da fattori economici ma che intendono regolamentare tutte le attività connesse al trasporto via mare a tutela delle risorse umane e dell’ambiente

    A comb-referenced difference-frequency spectrometer for cavity ring-down spectroscopy in the 4.5 μm region

    No full text
    We present a unique spectrometer combining absolute-frequency and high-sensitivity capabilities for precise investigation of molecular ro-vibrational spectra in the mid-IR. A coherent source based on a difference-frequency generation non-linear process in a periodically poled LiNbO3 crystal is referenced to an optical frequency-comb synthesizer. The generated radiation is coupled to a high-finesse Fabry–Perot cavity and the transmitted cavity ring-down signal is sensitive to very small gas absorbance. We tested the performance of our set-up on CO2 transition

    Hippo Pathway in Regulating Drug Resistance of Glioblastoma

    No full text
    Glioblastoma (GBM) represents the most common and malignant tumor of the Central Nervous System (CNS), affecting both children and adults. GBM is one of the deadliest tumor types and it shows a strong multidrug resistance (MDR) and an immunosuppressive microenvironment which remain a great challenge to therapy. Due to the high recurrence of GBM after treatment, the understanding of the chemoresistance phenomenon and how to stimulate the antitumor immune response in this pathology is crucial. The deregulation of the Hippo pathway is involved in tumor genesis, chemoresistance and immunosuppressive nature of GBM. This pathway is an evolutionarily conserved signaling pathway with a kinase cascade core, which controls the translocation of YAP (Yes-Associated Protein)/TAZ (Transcriptional Co-activator with PDZ-binding Motif) into the nucleus, leading to regulation of organ size and growth. With this review, we want to highlight how chemoresistance and tumor immunosuppression work in GBM and how the Hippo pathway has a key role in them. We linger on the role of the Hippo pathway evaluating the effect of its de-regulation among different human cancers. Moreover, we consider how different pathways are cross-linked with the Hippo signaling in GBM genesis and the hypothetical mechanisms responsible for the Hippo pathway activation in GBM. Furthermore, we describe various drugs targeting the Hippo pathway. In conclusion, all the evidence described largely support a strong involvement of the Hippo pathway in gliomas progression, in the activation of chemoresistance mechanisms and in the development of an immunosuppressive microenvironment. Therefore, this pathway is a promising target for the treatment of high grade gliomas and in particular of GBM

    High finesse optical cavity coupled with a quartz-enhanced photoacoustic spectroscopic sensor

    No full text
    An ultra-sensitive quartz-enhanced photoacoustic spectroscopy combined with a high-finesse cavity sensor platform is proposed as a novel gas sensing system.</p
    corecore