1,356 research outputs found

    Deep Markov Random Field for Image Modeling

    Full text link
    Markov Random Fields (MRFs), a formulation widely used in generative image modeling, have long been plagued by the lack of expressive power. This issue is primarily due to the fact that conventional MRFs formulations tend to use simplistic factors to capture local patterns. In this paper, we move beyond such limitations, and propose a novel MRF model that uses fully-connected neurons to express the complex interactions among pixels. Through theoretical analysis, we reveal an inherent connection between this model and recurrent neural networks, and thereon derive an approximated feed-forward network that couples multiple RNNs along opposite directions. This formulation combines the expressive power of deep neural networks and the cyclic dependency structure of MRF in a unified model, bringing the modeling capability to a new level. The feed-forward approximation also allows it to be efficiently learned from data. Experimental results on a variety of low-level vision tasks show notable improvement over state-of-the-arts.Comment: Accepted at ECCV 201

    Predator-Induced Vertical Behavior of a Ctenophore

    Get PDF
    Although many studies have focused on Mnemiopsis leidyi predation, little is known about the role of this ctenophore as prey when abundant in native and invaded pelagic systems. We examined the response of the ctenophore M. leidyi to the predatory ctenophore Beroe ovata in an experiment in which the two species could potentially sense each other while being physically separated. On average, M. leidyi responded to the predator’s presence by increasing variability in swimming speeds and by lowering their vertical distribution. Such behavior may help explain field records of vertical migration, as well as stratified and near-bottom distributions of M. leidyi

    Understanding and assessing the impact of treatment in diabetes: the Treatment-Related Impact Measures for Diabetes and Devices (TRIM-Diabetes and TRIM-Diabetes Device)

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>Diabetes is a debilitating illness requiring lifelong management. Treatments can be varied in terms of mode of administration as well as type of agent. Unfortunately, most patient reported outcome measures currently available to assess the impact of treatment are specific to diabetes type, treatment modality or delivery systems and are designed to be either a HRQoL or treatment satisfaction measure. To address these gaps, the Treatment Related Impact Measure-Diabetes and Device measures were developed. This paper presents the item development and validation of the TRIM Diabetes/Device.</p> <p>Methods</p> <p>Patient interviews were conducted to collect the patient perspective and ensure high content validity. Interviews were hand coded and qualitatively analyzed to identify common themes. A conceptual model of the impact of diabetes medication was developed and preliminary items for the TRIM-Diabetes/Device were generated and cognitively debriefed. Validation data was collected via an on-line survey and analyzed according to an a priori statistical analysis plan to validate the overall score as well as each domain. Item level criteria were used to reduce the preliminary item pool. Next, factor analysis to identify structural domains was performed. Reliability and validity testing was then performed.</p> <p>Results</p> <p>One hundred and five patients were interviewed in focus groups, individual interviews and for cognitive debriefing. Five hundred seven patients participated in the validation study. Factor analysis identified seven domains: Treatment Burden, Daily Life; Diabetes Management; Psychological Health; Compliance and Device Function and Bother. Internal consistency reliability coefficients of the TRIM-Diabetes/Device ranged from 0.80 and 0.94. Test-retest reliability of the TRIM-Diabetes/Device ranged from 0.71 to 0.89. All convergent and known groups validity hypotheses were met for the TRIM-Diabetes/Device total scores and sub-scales.</p> <p>Conclusion</p> <p>Validation is an ongoing and iterative process. These findings are the first step in that process and have shown that both the TRIM-Diabetes and the TRIM-Diabetes Device have acceptable psychometric properties. Future research is needed to continue the validation process and examine responsiveness and the validity of the TRIM-Diabetes/Device in a clinical trial population.</p

    RT-GENE: Real-time eye gaze estimation in natural environments

    Get PDF
    In this work, we consider the problem of robust gaze estimation in natural environments. Large camera-to-subject distances and high variations in head pose and eye gaze angles are common in such environments. This leads to two main shortfalls in state-of-the-art methods for gaze estimation: hindered ground truth gaze annotation and diminished gaze estimation accuracy as image resolution decreases with distance. We first record a novel dataset of varied gaze and head pose images in a natural environment, addressing the issue of ground truth annotation by measuring head pose using a motion capture system and eye gaze using mobile eyetracking glasses. We apply semantic image inpainting to the area covered by the glasses to bridge the gap between training and testing images by removing the obtrusiveness of the glasses. We also present a new real-time algorithm involving appearance-based deep convolutional neural networks with increased capacity to cope with the diverse images in the new dataset. Experiments with this network architecture are conducted on a number of diverse eye-gaze datasets including our own, and in cross dataset evaluations. We demonstrate state-of-the-art performance in terms of estimation accuracy in all experiments, and the architecture performs well even on lower resolution images

    Readability estimates for commonly used health-related quality of life surveys

    Get PDF
    To estimate readability of seven commonly used health-related quality of life instruments: SF-36, HUI, EQ-5D, QWB-SA, HALex, Minnesota Living with Heart Failure Questionnaire (MLHFQ), and the NEI-VFQ-25. The Flesch–Kincaid (F–K) and Flesch Reading Ease (FRE) formulae were used to estimate readability for every item in each measure. The percentage of items that require more than 5 years of formal schooling according to F–K was 50 for the EQ-5D, 53 for the SF-36, 80 for the VFQ-25, 85 for the QWB-SA, 100 for the HUI, HALex, and the MLHFQ. The percentage of items deemed harder than “easy” according to FRE was 50 for the SF-36, 67 for the EQ-5D, 79 for the QWB-SA, 80 for the VFQ-25, 100 for the HUI, HALex, and the MLHFQ. All seven surveys have a substantial number of items with high readability levels that may not be appropriate for the general population

    Minimal changes in health status questionnaires: distinction between minimally detectable change and minimally important change

    Get PDF
    Changes in scores on health status questionnaires are difficult to interpret. Several methods to determine minimally important changes (MICs) have been proposed which can broadly be divided in distribution-based and anchor-based methods. Comparisons of these methods have led to insight into essential differences between these approaches. Some authors have tried to come to a uniform measure for the MIC, such as 0.5 standard deviation and the value of one standard error of measurement (SEM). Others have emphasized the diversity of MIC values, depending on the type of anchor, the definition of minimal importance on the anchor, and characteristics of the disease under study. A closer look makes clear that some distribution-based methods have been merely focused on minimally detectable changes. For assessing minimally important changes, anchor-based methods are preferred, as they include a definition of what is minimally important. Acknowledging the distinction between minimally detectable and minimally important changes is useful, not only to avoid confusion among MIC methods, but also to gain information on two important benchmarks on the scale of a health status measurement instrument. Appreciating the distinction, it becomes possible to judge whether the minimally detectable change of a measurement instrument is sufficiently small to detect minimally important changes

    Search for New Physics in e mu X Data at D0 Using Sleuth: A Quasi-Model-Independent Search Strategy for New Physics

    Get PDF
    We present a quasi-model-independent search for the physics responsible for electroweak symmetry breaking. We define final states to be studied, and construct a rule that identifies a set of relevant variables for any particular final state. A new algorithm ("Sleuth") searches for regions of excess in those variables and quantifies the significance of any detected excess. After demonstrating the sensitivity of the method, we apply it to the semi-inclusive channel e mu X collected in 108 pb^-1 of ppbar collisions at sqrt(s) = 1.8 TeV at the D0 experiment during 1992-1996 at the Fermilab Tevatron. We find no evidence of new high p_T physics in this sample.Comment: 23 pages, 12 figures. Submitted to Physical Review

    Measurement of the top quark mass using the matrix element technique in dilepton final states

    Get PDF
    We present a measurement of the top quark mass in pp¯ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7  fb−1. The matrix element technique is applied to tt¯ events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton+jets final state of tt¯ decays is applied to jet energies. This correction provides a substantial reduction in systematic uncertainties. We obtain a top quark mass of mt=173.93±1.84  GeV

    Ratio of the Isolated Photon Cross Sections at \sqrt{s} = 630 and 1800 GeV

    Get PDF
    The inclusive cross section for production of isolated photons has been measured in \pbarp collisions at s=630\sqrt{s} = 630 GeV with the \D0 detector at the Fermilab Tevatron Collider. The photons span a transverse energy (ETE_T) range from 7-49 GeV and have pseudorapidity η<2.5|\eta| < 2.5. This measurement is combined with to previous \D0 result at s=1800\sqrt{s} = 1800 GeV to form a ratio of the cross sections. Comparison of next-to-leading order QCD with the measured cross section at 630 GeV and ratio of cross sections show satisfactory agreement in most of the ETE_T range.Comment: 7 pages. Published in Phys. Rev. Lett. 87, 251805, (2001
    corecore