799 research outputs found
Prevalence of Helicobacter pylori Infection in Peptic Ulcer Patients of Highly Endemic Kashmir Valley
Objective This study aimed to find out prevalence of Helicobacter pylori (H. pylori) in peptic ulcer disease (PUD) which is highly endemic disease in Kashmir
Spectral morphometric characterization of breast carcinoma cells
The spectral morphometric characteristics of standard haematoxylin and eosin breast carcinoma specimens were evaluated by light microscopy combined with a spectral imaging system. Light intensity at each wavelength in the range of 450–800 nm was recorded for 104 pixels from each field and represented as transmitted light spectra. A library of six characteristic spectra served to scan the cells and reconstruct new images depicting the nuclear area occupied by each spectrum. Fifteen cases of infiltrating ductal carcinoma and six cases of lobular carcinoma were examined; nine of the infiltrating ductal carcinoma and three of the lobular carcinoma showed an in situ component. The spectral morphometric analysis revealed a correlation between specific patterns of spectra and different groups of breast carcinoma cells. The most consistent result was that lobular carcinoma cells of in situ and infiltrating components from all patients showed a similar spectral pattern, whereas ductal carcinoma cells displayed spectral variety. Comparison of the in situ and the infiltrating ductal solid, cribriform and comedo carcinoma cells from the same patient revealed a strong similarity of the spectral elements and their relative distribution in the nucleus. The spectrum designated as number 5 in the library incorporated more than 40% of the nuclear area in 74.08% of the infiltrating lobular cells and in 13.64% of the infiltrating ductal carcinoma cells (P < 0.001). Spectrum number 2 appeared in all infiltrating ductal cells examined and in none of the lobular cells. These results indicate that spectrum number 5 is related to infiltrating lobular carcinoma, whereas spectrum number 2 is characteristic for infiltrating ductal carcinoma cells. Spectral similarity mapping of central necrotic regions of comedo type in situ carcinoma revealed nuclear fragmentation into defined segments composed of highly condensed chromatin. We conclude that the spectral morphometric features found for lobular and ductal cell populations may serve future automated histological diagnostics. © 1999 Cancer Research Campaig
Management of chemotherapy-associated febrile neutropenia
The development of febrile neutropenia during a course of chemotherapy is not only a life-threatening complication, it can also lead to a decision to reduce chemotherapy intensity in subsequent treatment cycles, thus putting patient outcomes at risk. Although there are strategies available for the primary prevention of febrile neutropenia, these are not widely used in the UK management of breast cancer. It is, therefore, paramount to have a well thought out and rigorously implemented care protocol for febrile neutropenia, involving patients, family/carers and health-care professionals in both primary and secondary care, to ensure early detection and effective management
Melanoma of the Anus Disguised as Hemorrhoids: Surgical Management Illustrated by a Case Report
Utilisation of an operative difficulty grading scale for laparoscopic cholecystectomy
Background
A reliable system for grading operative difficulty of laparoscopic cholecystectomy would standardise description of findings and reporting of outcomes. The aim of this study was to validate a difficulty grading system (Nassar scale), testing its applicability and consistency in two large prospective datasets.
Methods
Patient and disease-related variables and 30-day outcomes were identified in two prospective cholecystectomy databases: the multi-centre prospective cohort of 8820 patients from the recent CholeS Study and the single-surgeon series containing 4089 patients. Operative data and patient outcomes were correlated with Nassar operative difficultly scale, using Kendall’s tau for dichotomous variables, or Jonckheere–Terpstra tests for continuous variables. A ROC curve analysis was performed, to quantify the predictive accuracy of the scale for each outcome, with continuous outcomes dichotomised, prior to analysis.
Results
A higher operative difficulty grade was consistently associated with worse outcomes for the patients in both the reference and CholeS cohorts. The median length of stay increased from 0 to 4 days, and the 30-day complication rate from 7.6 to 24.4% as the difficulty grade increased from 1 to 4/5 (both p < 0.001). In the CholeS cohort, a higher difficulty grade was found to be most strongly associated with conversion to open and 30-day mortality (AUROC = 0.903, 0.822, respectively). On multivariable analysis, the Nassar operative difficultly scale was found to be a significant independent predictor of operative duration, conversion to open surgery, 30-day complications and 30-day reintervention (all p < 0.001).
Conclusion
We have shown that an operative difficulty scale can standardise the description of operative findings by multiple grades of surgeons to facilitate audit, training assessment and research. It provides a tool for reporting operative findings, disease severity and technical difficulty and can be utilised in future research to reliably compare outcomes according to case mix and intra-operative difficulty
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
Measurement of the Bottom-Strange Meson Mixing Phase in the Full CDF Data Set
We report a measurement of the bottom-strange meson mixing phase \beta_s
using the time evolution of B0_s -> J/\psi (->\mu+\mu-) \phi (-> K+ K-) decays
in which the quark-flavor content of the bottom-strange meson is identified at
production. This measurement uses the full data set of proton-antiproton
collisions at sqrt(s)= 1.96 TeV collected by the Collider Detector experiment
at the Fermilab Tevatron, corresponding to 9.6 fb-1 of integrated luminosity.
We report confidence regions in the two-dimensional space of \beta_s and the
B0_s decay-width difference \Delta\Gamma_s, and measure \beta_s in [-\pi/2,
-1.51] U [-0.06, 0.30] U [1.26, \pi/2] at the 68% confidence level, in
agreement with the standard model expectation. Assuming the standard model
value of \beta_s, we also determine \Delta\Gamma_s = 0.068 +- 0.026 (stat) +-
0.009 (syst) ps-1 and the mean B0_s lifetime, \tau_s = 1.528 +- 0.019 (stat) +-
0.009 (syst) ps, which are consistent and competitive with determinations by
other experiments.Comment: 8 pages, 2 figures, Phys. Rev. Lett 109, 171802 (2012
- …