126 research outputs found

    Not to Miss: Intronic Variants, Treatment, and Review of the Phenotypic Spectrum in VPS13D-Related Disorder

    Get PDF
    VPS13D is one of four human homologs of the vacuolar sorting protein 13 gene (VPS13). Biallelic pathogenic variants in the gene are associated with spastic ataxia or spastic paraplegia. Here, we report two patients with intronic pathogenic variants: one patient with early onset severe spastic ataxia and debilitating tremor, which is compound-heterozygous for a canonical (NM_018156.4: c.2237−1G > A) and a non-canonical (NM_018156.4: c.941+3G>A) splice site variant. The second patient carries the same non-canonical splice site variant in the homozygous state and is affected by late-onset spastic paraplegia. We confirmed altered splicing as a result of the intronic variants and demonstrated disturbed mitochondrial integrity. Notably, tremor in the first patient improved significantly by bilateral deep brain stimulation (DBS) in the ventralis intermedius (VIM) nucleus of the thalamus. We also conducted a literature review and summarized the phenotypical spectrum of reported VPS13D-related disorders. Our study underscores that looking for mutations outside the canonical splice sites is important not to miss a genetic diagnosis, especially in disorders with a highly heterogeneous presentation without specific red flags

    The Expanding Phenotypical Spectrum of WARS2 -Related Disorder : Four Novel Cases with a Common Recurrent Variant

    Get PDF
    Biallelic variants in the mitochondrial form of the tryptophanyl-tRNA synthetases (WARS2) can cause a neurodevelopmental disorder with movement disorders including early-onset tremor-parkinsonism syndrome. Here, we describe four new patients, who all presented at a young age with a tremor-parkinsonism syndrome and responded well to levodopa. All patients carry the same recurrent, hypomorphic missense variant (NM_015836.4: c.37T>G; p.Trp13Gly) either together with a previously described truncating variant (NM_015836.4: c.797Cdel; p.Pro266ArgfsTer10), a novel truncating variant (NM_015836.4: c.346C>T; p.Gln116Ter), a novel canonical splice site variant (NM_015836.4: c.349-1G>A), or a novel missense variant (NM_015836.4: c.475A>C, p.Thr159Pro). We investigated the mitochondrial function in patients and found increased levels of mitochondrially encoded cytochrome C Oxidase II as part of the mitochondrial respiratory chain as well as decreased mitochondrial integrity and branching. Finally, we conducted a literature review and here summarize the broad phenotypical spectrum of reported WARS2 -related disorders. In conclusion, WARS2 -related disorders are diagnostically challenging diseases due to the broad phenotypic spectrum and the disease relevance of a relatively common missense change that is often filtered out in a diagnostic setting since it occurs in ~0.5% of the general European population

    Measurement of the LT-asymmetry in \pi^0 electroproduction at the energy of the \Delta (1232) resonance

    Full text link
    The reaction p(e,e'p)pi^0 has been studied at Q^2=0.2 (GeV/c)^2 in the region of W=1232 MeV. From measurements left and right of q, cross section asymmetries \rho_LT have been obtained in forward kinematics \rho_LT(\theta_\pi^0=20deg) = (-11.68 +/- 2.36_stat +/- 2.36_sys)$ and backward kinematics \rho_LT(\theta_\pi^0=160deg) =(12.18 +/- 0.27_stat +/- 0.82_sys). Multipole ratios \Re(S_1+^* M_1+)/|M_1+|^2 and \Re(S_0+^* M_1+)/|M_1+|^2 were determined in the framework of the MAID2003 model. The results are in agreement with older data. The unusally strong negative \Re(S_0+^* M_1+)/|M_1+|^2 required to bring also the result of Kalleicher et al. in accordance with the rest of the data is almost excluded.Comment: 7 pages, 7 figures, 4 tables. Changed content. Accepted for publication in EPJ

    The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory

    Get PDF
    The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47"x47", resolved into 5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral resolution of ~175km/s. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the Performance Verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions

    Dosimetric precision of an ion beam tracking system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams.</p> <p>Methods</p> <p>A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion.</p> <p>Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system.</p> <p>Results</p> <p>All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum). Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3%) between measurements and calculations within the target volume for beam tracking (stationary) measurements.</p> <p>Conclusions</p> <p>The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems.</p

    Measurement of the beam-helicity asymmetry in the p(e_pol,e'p)pi_0 reaction at the energy of the Delta(1232) resonance

    Full text link
    In a p(e_pol,e'p)pi_0 out-of-plane coincidence experiment at the 3-spectrometer setup of the Mainz Microtron MAMI, the beam-helicity asymmetry has been precisely measured around the energy of the Delta(1232) resonance and Q^2 = 0.2 (GeV/c)^2. The results are in disagreement with three up-to-date model calculations. This is interpreted as lack of understanding of the non-resonant background, which in dynamical models is related to the pion cloud.Comment: 5 pages, 2 figures, 2 table

    4D treatment planning for scanned ion beams

    Get PDF
    At Gesellschaft für Schwerionenforschung (GSI) more than 330 patients have been treated with scanned carbon ion beams in a pilot project. To date, only stationary tumors have been treated. In the presence of motion, scanned ion beam therapy is not yet possible because of interplay effects between scanned beam and target motion which can cause severe mis-dosage. We have started a project to treat tumors that are subject to respiratory motion. A prototype beam application system for target tracking with the scanned pencil beam has been developed and commissioned

    Multiple star systems in the Orion nebula

    Get PDF
    This is the author accepted manuscript. The final fersion is available from EDP Sciences via the DOI in this record.This work presents an interferometric study of the massive-binary fraction in the Orion Trapezium cluster with the recently comissioned GRAVITY instrument. We observed a total of 16 stars of mainly OB spectral type. We find three previously unknown companions for θ1 Ori B, θ2 Ori B, and θ2 Ori C. We determined a separation for the previously suspected companion of NU Ori. We confirm four companions for θ1 Ori A, θ1 Ori C, θ1 Ori D, and θ2 Ori A, all with substantially improved astrometry and photometric mass estimates. We refined the orbit of the eccentric high-mass binary θ1 Ori C and we are able to derive a new orbit for θ1 Ori D. We find a system mass of 21.7 M⊙ and a period of 53 days. Together with other previously detected companions seen in spectroscopy or direct imaging, eleven of the 16 high-mass stars are multiple systems. We obtain a total number of 22 companions with separations up to 600 AU. The companion fraction of the early B and O stars in our sample is about two, significantly higher than in earlier studies of mostly OB associations. The separation distribution hints toward a bimodality. Such a bimodality has been previously found in A stars, but rarely in OB binaries, which up to this point have been assumed to be mostly compact with a tail of wider companions. We also do not find a substantial population of equal-mass binaries. The observed distribution of mass ratios declines steeply with mass, and like the direct star counts, indicates that our companions follow a standard power law initial mass function. Again, this is in contrast to earlier findings of flat mass ratio distributions in OB associations. We excluded collision as a dominant formation mechanism but find no clear preference for core accretion or competitive accretion.Marie Skłodowska-Curie Grant AgreementFCT-PortugalERC Starting Gran

    The CARMENES search for exoplanets around M dwarfs High-resolution optical and near-infrared spectroscopy of 324 survey stars

    Get PDF
    The CARMENES radial velocity (RV) survey is observing 324 M dwarfs to search for any orbiting planets. In this paper, we present the survey sample by publishing one CARMENES spectrum for each M dwarf. These spectra cover the wavelength range 520–1710 nm at a resolution of at least R >80 000, and we measure its RV, Hα emission, and projected rotation velocity. We present an atlas of high-resolution M-dwarf spectra and compare the spectra to atmospheric models. To quantify the RV precision that can be achieved in low-mass stars over the CARMENES wavelength range, we analyze our empirical information on the RV precision from more than 6500 observations. We compare our high-resolution M-dwarf spectra to atmospheric models where we determine the spectroscopic RV information content, Q, and signal-to-noise ratio. We find that for all M-type dwarfs, the highest RV precision can be reached in the wavelength range 700–900 nm. Observations at longer wavelengths are equally precise only at the very latest spectral types (M8 and M9). We demonstrate that in this spectroscopic range, the large amount of absorption features compensates for the intrinsic faintness of an M7 star. To reach an RV precision of 1 m s−1 in very low mass M dwarfs at longer wavelengths likely requires the use of a 10 m class telescope. For spectral types M6 and earlier, the combination of a red visual and a near-infrared spectrograph is ideal to search for low-mass planets and to distinguish between planets and stellar variability. At a 4 m class telescope, an instrument like CARMENES has the potential to push the RV precision well below the typical jitter level of 3–4 m s−1
    corecore