746 research outputs found

    Technical Note: Characterization of a static thermal-gradient CCN counter

    No full text
    International audienceThe static (parallel-plate thermal-gradient) diffusion chamber (SDC) was one of the first instruments designed to measure cloud condensation nuclei (CCN) concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered supersaturation because of water vapor depletion with increasing particle concentration. The results obtained give a better understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail and can, in parts, be used for calibrations also for other types of CCN counters. We conclude the following: 1) it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2) the number concentration calibration needs to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3) we observed no evidence that water vapor depletion lowered the supersaturation

    Technical note: A method for measuring size-resolved CCN in the atmosphere

    No full text
    International audienceWe present a method to investigate cloud condensation nuclei (CCN) concentrations and activation efficiencies as a function of two independent variables, aerosol particle size and water vapor supersaturation. To date, most ambient CCN measurements have been made as the integral (total) CCN concentration as a function of water vapor supersaturation only. However, since CCN properties of aerosol particles are strongly dependent on particle size, as well as on chemical composition, which commonly varies with particle size, more detailed measurements can provide additional important information about the CCN activation. With size-resolved measurements, the effect of particle size on CCN activity can be kept constant, which makes it possible to directly assess the influence of particle chemistry. The instrumental set-up consists of a differential mobility analyzer (DMA) to select particles of a known size, within a narrow size range. A condensation nuclei (CN) counter (condensation particle counter, CPC) is used to count the total number of particles in that size range, and a CCN counter is used to count the number of CCN as a function of supersaturation, in that same size range. The activation efficiency, expressed as CCN/CN ratios, can thus directly be calculated as a function of particle size and supersaturation. We present examples of the application of this technique, using salt and smoke aerosols produced in the laboratory as well as ambient aerosols

    MORBIDITY AND MORTALITY FACTORS IN PRE-FLEDGED FLORIDA SANDHILL CRANE (GRUS CANADENSIS PRATENSIS) CHICKS

    Get PDF
    One hundred and fifteen Florida sandhill crane (Grus canadensis pratensis) chicks were captured in Osceola and Lake Counties, Florida in 1998 - 2000 and examined for evidence of disease. Evidence of Eimeria gruis and/or E. reichenowi infection was found in 52% of chicks examined. Ten chicks were positive for antibodies to St. Louis encephalitis virus and 1 of these chicks was also positive for antibodies to eastern equine encephalitis virus. Predation was the most commonly identified cause of mortality. An unidentified microfilaria, and an unknown protozoan were detected in blood smears from crane chicks. A number of other disease conditions were also encountered, including: ant bites, chigger infestations, helminth infections, bacterial infections, leg problems associated with capture, and a bill deformity

    Calibration and measurement uncertainties of a continuous-flow cloud condensation nuclei counter (DMT-CCNC): CCN activation of ammonium sulfate and sodium chloride aerosol particles in theory and experiment

    Get PDF
    International audienceExperimental and theoretical uncertainties in the measurement of cloud condensation nuclei (CCN) with a continuous-flow thermal-gradient CCN counter from Droplet Measurement Technologies (DMT-CCNC) have been assessed by model calculations and calibration experiments with ammonium sulfate and sodium chloride aerosol particles in the diameter range of 20?220 nm. Experiments have been performed in the laboratory and during field measurement campaigns, extending over a period of more than one year and covering a wide range of operating conditions (650?1020 hPa ambient pressure, 0.5?1.0 L min?1 aerosol flow rate, 20?30°C inlet temperature, 4?34 K m?1 temperature gradient). For each set of conditions, the effective water vapor supersaturation (Seff) in the CCNC was determined from the measured CCN activation spectra and Köhler model calculations. High measurement precision was achieved under stable laboratory conditions, where relative variations of Seff in the CCNC were generally less than ±2%. During field measurements, however, the relative variability increased up to ±5?7%, which can be mostly attributed to variations of the CCNC column top temperature with ambient temperature. To assess the accuracy of the Köhler models used to calculate Seff, we have performed a comprehensive comparison and uncertainty analysis of the various Köhler models and thermodynamic parameterizations commonly used in CCN studies. For the relevant supersaturation range (0.05?2%), the relative deviations between different modeling approaches were as high as 25% for (NH4)2SO4 and 16% for NaCl. The deviations were mostly caused by the different parameterizations for the activity of water in aqueous solutions of (NH4)2SO4 and NaCl (activity parameterization, osmotic coefficient, and van't Hoff factor models). The uncertainties related to the model parameterizations of water activity clearly exceeded the CCNC measurement precision. Relative deviations caused by different ways of calculating or approximating solution density and surface tension did not exceed 3% for (NH4)2SO4 and 1.5% for NaCl. Nevertheless, they did exceed the CCNC measurement precision under well-defined operating conditions and should not be neglected in studies aimed at high accuracy. To ensure comparability of results, we suggest that CCN studies should always report exactly which Köhler model equations and parameterizations of solution properties were used. Substantial differences between the CCNC calibration results obtained with (NH4)2SO4 and NaCl aerosols under equal experimental conditions (relative deviations of Seff up to ~10%) indicate inconsistencies between widely used activity parameterizations derived from electrodynamic balance (EDB) single particle experiments (Tang and Munkelwitz, 1994; Tang, 1996) and hygroscopicity tandem differential mobility analyzer (HTDMA) aerosol experiments (Kreidenweis et al., 2005). Therefore, we see a need for further evaluation and experimental confirmation of preferred data sets and parameterizations for the activity of water in dilute aqueous (NH4)2SO4 and NaCl solutions. The experimental results were also used to test the CCNC flow model of Lance et al.~(2006), which describes the dependence of Seff on temperature, pressure, and flow rate in the CCN counter. This model could be applied after subtraction of a near-constant temperature offset and derivation of an instrument-specific thermal resistance parameter (RT?1.8 K W?1). At Seff>0.1% the relative deviations between the flow model and experimental results were mostly less than 5%, when the same Köhler model approach was used. At Seff?.1%, however, the deviations exceeded 20%, which can be attributed to non-idealities which also caused the near-constant temperature offset. Therefore, we suggest that the CCNC flow model can be used to extrapolate calibration results, but should generally be complemented by calibration experiments performed under the relevant operating conditions ? during field campaigns as well as in laboratory studies

    Experimental Long-Distance Decoy-State Quantum Key Distribution Based On Polarization Encoding

    Full text link
    We demonstrate the decoy-state quantum key distribution (QKD) with one-way quantum communication in polarization space over 102km. Further, we simplify the experimental setup and use only one detector to implement the one-way decoy-state QKD over 75km, with the advantage to overcome the security loopholes due to the efficiency mismatch of detectors. Our experimental implementation can really offer the unconditionally secure final keys. We use 3 different intensities of 0, 0.2 and 0.6 for the pulses of source in our experiment. In order to eliminate the influences of polarization mode dispersion in the long-distance single-mode optical fiber, an automatic polarization compensation system is utilized to implement the active compensation.Comment: 4 pages,3 figure

    THE CHANGING ECONOMIC SPATIAL STRUCTURE OF EUROPE

    Get PDF
    Many theoretical and practical works aim at describing the spatial structure of Europe, where spatial relations have undergone continuous change. This article gives an overview of models describing the spatial structure of Europe. Their diversity is highlighted by listing of these models, without any claim to completeness. Our study aims at describing the economic spatial structure of Europe with bi-dimensional regression analysis based on the gravitational model. With the help of the gravity model, we get a spatial image of the spatial structure of Europe. With these images, we can justify the appropriateness of the models based on different methodological backgrounds by comparing them with our results. Our goal is not to create and show a new model that overwrites the existing ones, but rather to contribute to understanding the European spatial structure through a new methodological approach

    A quantum gate array can be programmed to evaluate the expectation value of any operator

    Get PDF
    A programmable gate array is a circuit whose action is controlled by input data. In this letter we describe a special--purpose quantum circuit that can be programmed to evaluate the expectation value of any operator OO acting on a space of states of NN dimensions. The circuit has a program register whose state ∣Κ(O)>P|\Psi(O)>_P encodes the operator OO whose expectation value is to be evaluated. The method requires knowledge of the expansion of OO in a basis of the space of operators. We discuss some applications of this circuit and its relation to known instances of quantum state tomography.Comment: 4 pages, 3 figures include

    Water uptake by biomass burning aerosol at sub- and supersaturated conditions: closure studies and implications for the role of organics

    Get PDF
    We investigate the CCN activity of freshly emitted biomass burning particles and their hygroscopic growth at a relative humidity (RH) of 85%. The particles were produced in the Mainz combustion laboratory by controlled burning of various wood types. The water uptake at sub- and supersaturations is parameterized by the hygroscopicity parameter, Îș (c.f. Petters and Kreidenweis, 2007). For the wood burns, Îș is low, generally around 0.06. The main emphasis of this study is a comparison of Îș derived from measurements at sub- and supersaturated conditions (ÎșG and ÎșCCN), in order to see whether the water uptake at 85% RH can predict the CCN properties of the biomass burning particles. Differences in ÎșGand ÎșCCN can arise through solution non-idealities, the presence of slightly soluble or surface active compounds, or non-spherical particle shape. We find that ÎșG and ÎșCCN agree within experimental uncertainties (of around 30%) for particle sizes of 100 and 150 nm; only for 50 nm particles is ÎșCCN larger than ÎșG by a factor of 2. The magnitude of this difference and its dependence on particle size is consistent with the presence of surface active organic compounds. These compounds mainly facilitate the CCN activation of small particles, which form the most concentrated solution droplets at the point of activation. The 50 nm particles, however, are only activated at supersaturations higher than 1% and are therefore of minor importance as CCN in ambient clouds. By comparison with the actual chemical composition of the biomass burning particles, we estimate that the hygroscopicity of the water-soluble organic carbon (WSOC) fraction can be represented by a ÎșWSOC value of approximately 0.2. The effective hygroscopicity of a typical wood burning particle can therefore be represented by a linear mixture of an inorganic component with Îș ≅ 0.6, a WSOC component with Îș ≅ 0.2, and an insoluble component with Îș = 0
    • 

    corecore