75 research outputs found

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (VT) size was 500 ml, or 7 to 9 ml kg1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P < 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P < 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high VT and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome

    Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - An observational study in 29 countries

    Get PDF
    BACKGROUND Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. OBJECTIVES To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. DESIGN This was a prospective international 1-week observational study using the ‘Assess Respiratory Risk in Surgical Patients in Catalonia risk score’ (ARISCAT score) for PPC for risk stratification. PATIENTS AND SETTING Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. MAIN OUTCOME MEASURES The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. RESULTS A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (V T) size was 500 ml, or 7 to 9 ml kg−1 predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P ˂ 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P ˂ 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. CONCLUSION The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high V T and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome.</p

    Intended and Unintended Consequences of Mandatory IFRS Adoption: A Review of Extant Evidence and Suggestions for Future Research

    Full text link
    This paper discusses empirical evidence on the economic consequences of mandatory adoption of International Financial Reporting Standards (IFRS) in the European Union (EU) and provides suggestions on how future research can add to our understanding of these effects. Based on the explicitly stated objectives of the EU's so-called 'IAS Regulation', we distinguish between intended and unintended consequences of mandatory IFRS adoption. Empirical research on the intended consequences generally fails to document an increase in the comparability or transparency of financial statements. In contrast, there is rich and almost unanimous evidence of positive effects on capital markets and at the macroeconomic level. We argue that certain research design issues are likely to contribute to this apparent mismatch in findings and we suggest areas for future research to address it. The literature investigating unintended consequences of mandatory IFRS adoption is still in its infancy. However, extant empirical evidence and insights from non-IFRS settings suggest that mandatory IFRS adoption has the potential to materially affect contractual outcomes. We conclude that both the intended and the unintended consequences deserve further scrutiny to assess the costs and benefits of mandatory IFRS adoption, which may help provide a basis for evaluating the effectiveness of the IAS Regulation. We provide specific guidance for future research in this field

    A new, improved sensor for ascorbate determination at copper hexacyanoferrate modified carbon film electrodes

    Get PDF
    A new, improved sensor for the electrocatalytic determination of ascorbate has been developed that has both a low applied operating potential and a low detection limit. The sensor was constructed by depositing copper hexacyanoferrate film either electrochemically or chemically onto carbon film electrode, and it was then characterised by cyclic voltammetry and electrochemical impedance spectroscopy. Chemically deposited films were shown to be the best for ascorbate determination and were used as an amperometric sensor at +0.05 V versus SCE to determine ascorbate in wines and juice. The linear range extended to 5 mM with a limit of detection of 2.1 µM, the sensor was stable for more than four months, and it could be used continuously for at least 20 days
    corecore